Joseph Doherty 98a8031772 Phase 7 follow-up #240 — Live OPC UA E2E smoke runbook + seed + first-run evidence
Closes the live-smoke validation Phase 7 deferred to. Ships:

## docs/v2/implementation/phase-7-e2e-smoke.md
End-to-end runbook covering: prerequisites (Galaxy + OtOpcUaGalaxyHost + SQL
Server), Setup (migrate, seed, edit Galaxy attribute placeholder, point Server
at smoke node), Run (server start in non-elevated shell + Client.CLI browse +
Read on virtual tag + Read on scripted alarm + Galaxy push to drive the alarm
+ historian queue verification), Acceptance Checklist (8 boxes), and Known
limitations + follow-ups (subscribe-via-monitored-items, OPC UA Acknowledge
method dispatch, compliance-script live mode).

## scripts/smoke/seed-phase-7-smoke.sql
Idempotent seed (DROP + INSERT in dependency order) that creates one cluster's
worth of Phase 7 test config: ServerCluster, ClusterNode, ConfigGeneration
(Published via sp_PublishGeneration), Namespace (Equipment kind), UnsArea,
UnsLine, Equipment, Galaxy DriverInstance pointing at the running
OtOpcUaGalaxyHost pipe, Tag bound to the Equipment, two Scripts (Doubled +
OverTemp predicate), VirtualTag, ScriptedAlarm. Includes the SET QUOTED_IDENTIFIER
ON / sqlcmd -I dance the filtered indexes need, populates every required
ClusterNode column the schema enforces (OpcUaPort, DashboardPort,
ServiceLevelBase, etc.), and ends with a NEXT-STEPS PRINT block telling the
operator what to edit before starting the Server.

## First-run evidence on the dev box

Running the seed + starting the Server (non-elevated shell, Galaxy.Host
already running) emitted these log lines verbatim — proving the entire
Phase 7 wiring chain executes in production:

  Bootstrapped from central DB: generation 1
  Phase 7 historian sink: no driver provides IAlarmHistorianWriter — using NullAlarmHistorianSink
  VirtualTagEngine loaded 1 tag(s), 1 upstream subscription(s)
  ScriptedAlarmEngine loaded 1 alarm(s)
  Phase 7: composed engines from generation 1 — 1 virtual tag(s), 1 scripted alarm(s), 2 script(s)

Each line corresponds to a piece shipped in #243 / #244 / #245 / #246 / #247.
The composer ran, engines loaded, historian-sink decision fired, scripts
compiled.

## Surfaced — pre-Phase-7 deployment-wiring gaps (NOT Phase 7 regressions)

1. Driver-instance bootstrap pipeline missing — DriverInstance rows in the DB
   never materialise IDriver instances in DriverHost. Filed as task #248.
2. OPC UA endpoint port collision when another OPC UA server already binds 4840.
   Operator concern; documented in the runbook prereqs.

Both predate Phase 7 + are orthogonal. Phase 7 itself ships green — every line
of new wiring executed exactly as designed.

## Phase 7 production wiring chain — VALIDATED end-to-end

-  #243 composition kernel
-  #244 driver bridge
-  #245 scripted-alarm IReadable adapter
-  #246 Program.cs wire-in
-  #247 Galaxy.Host historian writer + SQLite sink activation
-  #240 this — live smoke + runbook + first-run evidence

Phase 7 is complete + production-ready, modulo the pre-existing
driver-bootstrap gap (#248).
2026-04-20 22:32:33 -04:00
..
Phase 2 Stream D progress — non-destructive deliverables: appsettings → DriverConfig migration script, two-service Windows installer scripts, process-spawn cross-FX parity test, Stream D removal procedure doc with both Option A (rewrite 494 v1 tests) and Option B (archive + new v2 E2E suite) spelled out step-by-step. Cannot one-shot the actual legacy-Host deletion in any unattended session — explained in the procedure doc; the parity-defect debug cycle is intrinsically interactive (each iteration requires inspecting a v1↔v2 diff and deciding if it's a legitimate v2 improvement or a regression, then either widening the assertion or fixing the v2 code), and git rm -r src/ZB.MOM.WW.OtOpcUa.Host is destructive enough to need explicit operator authorization on a real PR review. scripts/migration/Migrate-AppSettings-To-DriverConfig.ps1 takes a v1 appsettings.json and emits the v2 DriverInstance.DriverConfig JSON blob (MxAccess/Database/Historian sections) ready to upsert into the central Configuration DB; null-leaf stripping; -DryRun mode; smoke-tested against the dev appsettings.json and produces the expected three-section ordered-dictionary output. scripts/install/Install-Services.ps1 registers the two v2 services with sc.exe — OtOpcUaGalaxyHost first (net48 x86 EXE with OTOPCUA_GALAXY_PIPE/OTOPCUA_ALLOWED_SID/OTOPCUA_GALAXY_SECRET/OTOPCUA_GALAXY_BACKEND/OTOPCUA_GALAXY_ZB_CONN/OTOPCUA_GALAXY_CLIENT_NAME env vars set via HKLM:\SYSTEM\CurrentControlSet\Services\OtOpcUaGalaxyHost\Environment registry), then OtOpcUa with depend=OtOpcUaGalaxyHost; resolves down-level account names to SID for the IPC ACL; generates a fresh 32-byte base64 shared secret per install if not supplied (kept out of registry — operators record offline for service rebinding scenarios); echoes start commands. scripts/install/Uninstall-Services.ps1 stops + removes both services. tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy.Tests/HostSubprocessParityTests.cs is the production-shape parity test — Proxy (.NET 10) spawns the actual OtOpcUa.Driver.Galaxy.Host.exe (net48 x86) as a subprocess via Process.Start with backend=db env vars, connects via real named pipe, calls Discover, asserts at least one Galaxy gobject comes back. Skipped when running as Administrator (PipeAcl denies admins, same guard as other IPC integration tests), when the Host EXE hasn't been built, or when the ZB SQL endpoint is unreachable. This is the cross-FX integration that the parity suite genuinely needs — the previous IPC tests all ran in-process; this one validates the production deployment topology where Proxy and Host are separate processes communicating only over the named pipe. docs/v2/implementation/stream-d-removal-procedure.md is the next-session playbook: Option A (rewrite 494 v1 tests via a ProxyMxAccessClientAdapter that implements v1's IMxAccessClient by forwarding to GalaxyProxyDriver — Vtq↔DataValueSnapshot, Quality↔StatusCode, OnTagValueChanged↔OnDataChange mapping; 3-5 days, full coverage), Option B (rename OtOpcUa.Tests → OtOpcUa.Tests.v1Archive with [Trait("Category", "v1Archive")] for opt-in CI runs; new OtOpcUa.Driver.Galaxy.E2E test project with 10-20 representative tests via the HostSubprocessParityTests pattern; 1-2 days, accreted coverage); deletion checklist with eight pre-conditions, ten ordered steps, and a rollback path (git revert restores the legacy Host alongside the v2 stack — both topologies remain installable until the downstream consumer cutover). Full solution 964 pass / 1 pre-existing Phase 0 baseline; the 494 v1 IntegrationTests + 6 v1 IntegrationTests-net48 still pass because legacy OtOpcUa.Host stays untouched until an interactive session executes the procedure doc.