Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Mitsubishi/MitsubishiProfile.cs
T
Joseph Doherty 64e3fbe035
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
docs: backfill XML documentation across 756 files
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00

47 lines
2.0 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.Mitsubishi;
/// <summary>
/// Tag map for the Mitsubishi MELSEC device class with a representative Modbus Device
/// Assignment block mapping D0..D1023 → HR[0..1023]. Mirrors the behaviors in
/// <c>mitsubishi.json</c> pymodbus profile and <c>docs/v2/mitsubishi.md</c>.
/// </summary>
/// <remarks>
/// MELSEC Modbus sites all have *different* device-assignment parameter blocks; this profile
/// models the conventional default. Per-model differences (FX5U needs firmware ≥ 1.060 for
/// Modbus server; QJ71MT91 lacks FC22/FC23; FX/iQ-F use octal X/Y while Q/L/iQ-R use hex)
/// are handled in <see cref="MelsecAddress"/> (PR 59) and the per-model test files.
/// </remarks>
public static class MitsubishiProfile
{
/// <summary>
/// Scratch HR the smoke test writes + reads. Address 200 mirrors the
/// dl205/s7_1500/standard scratch range so one smoke test pattern works across every
/// device profile the simulator supports.
/// </summary>
public const ushort SmokeHoldingRegister = 200;
/// <summary>Value the smoke test writes then reads back.</summary>
public const short SmokeHoldingValue = 7890;
/// <summary>Builds Modbus driver options configured for the Mitsubishi profile.</summary>
/// <param name="host">The Modbus server hostname or IP address.</param>
/// <param name="port">The Modbus server port number.</param>
public static ModbusDriverOptions BuildOptions(string host, int port) => new()
{
Host = host,
Port = port,
UnitId = 1,
Timeout = TimeSpan.FromSeconds(2),
Tags =
[
new ModbusTagDefinition(
Name: "Smoke_HReg200",
Region: ModbusRegion.HoldingRegisters,
Address: SmokeHoldingRegister,
DataType: ModbusDataType.Int16,
Writable: true),
],
Probe = new ModbusProbeOptions { Enabled = false },
};
}