lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/DL205/DL205VMemoryQuirkTests.cs
T
Joseph Doherty 64e3fbe035
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
docs: backfill XML documentation across 756 files
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00

94 lines
4.2 KiB
C#

using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
/// <summary>
/// Verifies the DL205/DL260 V-memory octal addressing quirk end-to-end: use
/// <see cref="DirectLogicAddress.UserVMemoryToPdu"/> to translate <c>V2000</c> octal into
/// the Modbus PDU address actually dispatched, then read the marker the dl205.json profile
/// placed at that address. HR[0x0400] = 0x2000 proves the translation was performed
/// correctly — a naïve caller treating "V2000" as decimal 2000 would read HR[2000] (which
/// the profile leaves at 0) and miss the marker entirely.
/// </summary>
[Collection(ModbusSimulatorCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "DL205")]
public sealed class DL205VMemoryQuirkTests(ModbusSimulatorFixture sim)
{
/// <summary>Verifies that DL205 V2000 user memory octal address resolves to PDU address 0x0400.</summary>
[Fact]
public async Task DL205_V2000_user_memory_resolves_to_PDU_0x0400_marker()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
StringComparison.OrdinalIgnoreCase))
{
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed V-memory markers).");
}
var pdu = DirectLogicAddress.UserVMemoryToPdu("V2000");
pdu.ShouldBe((ushort)0x0400);
var options = new ModbusDriverOptions
{
Host = sim.Host,
Port = sim.Port,
UnitId = 1,
Timeout = TimeSpan.FromSeconds(2),
Tags =
[
new ModbusTagDefinition("DL205_V2000",
ModbusRegion.HoldingRegisters, Address: pdu,
DataType: ModbusDataType.UInt16, Writable: false),
],
Probe = new ModbusProbeOptions { Enabled = false },
};
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-vmem");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["DL205_V2000"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
results[0].Value.ShouldBe((ushort)0x2000, "dl205.json seeds HR[0x0400] with marker 0x2000 (= V2000 value)");
}
/// <summary>Verifies that DL205 V40400 system memory address resolves to PDU address 0x2100.</summary>
[Fact]
public async Task DL205_V40400_system_memory_resolves_to_PDU_0x2100_marker()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
StringComparison.OrdinalIgnoreCase))
{
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
}
// V40400 is system memory on DL260 / H2-ECOM100 absolute mode; it does NOT follow the
// simple octal-to-decimal formula (40400 octal = 16640 decimal, which would read HR[0x4100]).
// The CPU places the system bank at PDU 0x2100 instead. Proving the helper routes there.
var pdu = DirectLogicAddress.SystemVMemoryToPdu(0);
pdu.ShouldBe((ushort)0x2100);
var options = new ModbusDriverOptions
{
Host = sim.Host,
Port = sim.Port,
UnitId = 1,
Timeout = TimeSpan.FromSeconds(2),
Tags =
[
new ModbusTagDefinition("DL205_V40400",
ModbusRegion.HoldingRegisters, Address: pdu,
DataType: ModbusDataType.UInt16, Writable: false),
],
Probe = new ModbusProbeOptions { Enabled = false },
};
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-sysv");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["DL205_V40400"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
results[0].Value.ShouldBe((ushort)0x4040, "dl205.json seeds HR[0x2100] with marker 0x4040 (= V40400 value)");
}
}