9b51dbca60
The mock had served the shapes the driver once agreed with it on, so it validated the very defects just fixed: it ANSWERED the non-existent 0x00D3 cnc_getfigure, wrote base/exponent 0/0 into position blocks, put the macro decimal at offset 4, and served spindle 'max rpm' as a raw constant. Ported from the sister ignitionoee mock (local divergence recorded in VENDORED.md; the LE timer and alarm cap are kept): - 0x00D3 refused with EW_FUNC, as the real control does. - 0x0026 blocks carry base 10 / position_figures exponent; signed arg2, arg2 = 0 or past the axis count refused EW_ATTRIB. - cnc_rdmacro is the 8-byte ODBM shape, 9-digit mantissa, unset = vacant. - servo/spindle meter records carry the envelope; spindle meters are 1/16384-of-full-scale counts (motor speed = speed / max_rpm). Integration tests: spindle test reads Load/MotorSpeedPct percentages; the position-scale test now proves the block's own scale wins; new Vacant_positions_and_macros_read_bad_over_the_wire. 12/12 pass against the mock run locally (python -m focas_mock.cli serve, OTOPCUA_FOCAS_SIM_ENDPOINT).
295 lines
12 KiB
C#
295 lines
12 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Wire;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.IntegrationTests.Series;
|
|
|
|
/// <summary>
|
|
/// Dual-run companion to <see cref="FixedTreePopulatesTests"/> — exercises the same
|
|
/// fixed-tree scenarios through the pure-managed <see cref="WireFocasClient"/>
|
|
/// instead of the shim/P-Invoke path. Proves both backends observe identical
|
|
/// state against the same focas-mock instance.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// Scheduled for removal in Wire migration phase 3 (task #104) once the shim is
|
|
/// deleted — at that point only this class survives and becomes the canonical
|
|
/// fixed-tree integration test.
|
|
/// </remarks>
|
|
[Collection(FocasSimCollection.Name)]
|
|
public sealed class WireBackendTests
|
|
{
|
|
private readonly FocasSimFixture _fx;
|
|
|
|
/// <summary>
|
|
/// Initializes a new instance of the <see cref="WireBackendTests"/> class.
|
|
/// </summary>
|
|
/// <param name="fx">The FOCAS simulator fixture.</param>
|
|
public WireBackendTests(FocasSimFixture fx) => _fx = fx;
|
|
|
|
// Derived from the fixture endpoint (OTOPCUA_FOCAS_SIM_ENDPOINT) so the driver dials the SAME
|
|
// mock the fixture probed — a remote fixture on the Docker host, not a hardcoded 127.0.0.1.
|
|
private string DeviceHost => _fx.DeviceUri;
|
|
|
|
/// <summary>Verifies that identity axes and dynamic data populate via the wire backend.</summary>
|
|
[Fact]
|
|
public async Task Identity_axes_and_dynamic_populate_via_wire_backend()
|
|
{
|
|
if (_fx.SkipReason is not null) Assert.Skip(_fx.SkipReason);
|
|
var ct = TestContext.Current.CancellationToken;
|
|
|
|
await _fx.LoadProfileAsync("FWLIB64", ct);
|
|
await _fx.PatchStateAsync(new
|
|
{
|
|
sysinfo = new
|
|
{
|
|
addinfo = 0, max_axis = 8, cnc_type = "M ", mt_type = "M ",
|
|
series = "30i ", version = "A1.0", axes = "3 ",
|
|
},
|
|
axis_names = new[] { "X", "Y", "Z" },
|
|
rddynamic2 = new
|
|
{
|
|
axis = 1, alarm = 0, prgnum = 1, prgmnum = 1, seqnum = 42,
|
|
actf = 1500, acts = 3200,
|
|
pos = new { absolute = 123456, machine = 123450, relative = 6, distance = 0 },
|
|
},
|
|
}, ct);
|
|
|
|
var driver = new FocasDriver(new FocasDriverOptions
|
|
{
|
|
Devices = [new FocasDeviceOptions(DeviceHost)],
|
|
RawTags = [],
|
|
Probe = new FocasProbeOptions { Enabled = false },
|
|
FixedTree = new FocasFixedTreeOptions
|
|
{
|
|
Enabled = true,
|
|
PollInterval = TimeSpan.FromMilliseconds(100),
|
|
},
|
|
}, driverInstanceId: "focas-wire-identity", clientFactory: new WireFocasClientFactory());
|
|
|
|
await using (driver)
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
|
|
await WaitFor(() =>
|
|
driver.GetDeviceState(DeviceHost) is { FixedTreeCache: not null }, TimeSpan.FromSeconds(5));
|
|
|
|
var state = driver.GetDeviceState(DeviceHost);
|
|
state.ShouldNotBeNull();
|
|
state.FixedTreeCache.ShouldNotBeNull();
|
|
state.FixedTreeCache.SysInfo.Series.ShouldStartWith("30i");
|
|
state.FixedTreeCache.Axes.Count.ShouldBe(3);
|
|
state.FixedTreeCache.Axes[0].Display.ShouldBe("X");
|
|
|
|
await WaitFor(() =>
|
|
state.LastFixedSnapshots.ContainsKey($"{DeviceHost}/Axes/X/AbsolutePosition"),
|
|
TimeSpan.FromSeconds(3));
|
|
state.LastFixedSnapshots[$"{DeviceHost}/Axes/X/AbsolutePosition"].ShouldBe(123456);
|
|
}
|
|
}
|
|
|
|
/// <summary>Verifies that program and operation mode data populate via the wire backend.</summary>
|
|
[Fact]
|
|
public async Task Program_and_operation_mode_populate_via_wire_backend()
|
|
{
|
|
if (_fx.SkipReason is not null) Assert.Skip(_fx.SkipReason);
|
|
var ct = TestContext.Current.CancellationToken;
|
|
|
|
await _fx.LoadProfileAsync("FWLIB64", ct);
|
|
await _fx.PatchStateAsync(new
|
|
{
|
|
sysinfo = new
|
|
{
|
|
addinfo = 0, max_axis = 8, cnc_type = "M ", mt_type = "M ",
|
|
series = "30i ", version = "A1.0", axes = "1 ",
|
|
},
|
|
axis_names = new[] { "X" },
|
|
rddynamic2 = new
|
|
{
|
|
axis = 1, alarm = 0, prgnum = 42, prgmnum = 42, seqnum = 100,
|
|
actf = 0, acts = 0,
|
|
pos = new { absolute = 0, machine = 0, relative = 0, distance = 0 },
|
|
},
|
|
program = new
|
|
{
|
|
current = 42, main = 42, sequence = 100, block_count = 17,
|
|
executing_path = "O0042.NC",
|
|
},
|
|
operation_mode = new { mode = 3 },
|
|
}, ct);
|
|
|
|
var driver = new FocasDriver(new FocasDriverOptions
|
|
{
|
|
Devices = [new FocasDeviceOptions(DeviceHost)],
|
|
RawTags = [],
|
|
Probe = new FocasProbeOptions { Enabled = false },
|
|
FixedTree = new FocasFixedTreeOptions
|
|
{
|
|
Enabled = true,
|
|
PollInterval = TimeSpan.FromMilliseconds(100),
|
|
ProgramPollInterval = TimeSpan.FromMilliseconds(200),
|
|
},
|
|
}, driverInstanceId: "focas-wire-program", clientFactory: new WireFocasClientFactory());
|
|
|
|
await using (driver)
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
|
|
await WaitFor(() =>
|
|
driver.GetDeviceState(DeviceHost) is { LastProgramInfo: not null },
|
|
TimeSpan.FromSeconds(5));
|
|
|
|
var snapshots = await driver.ReadAsync(
|
|
[$"{DeviceHost}/Program/Name",
|
|
$"{DeviceHost}/Program/ONumber",
|
|
$"{DeviceHost}/Program/BlockCount",
|
|
$"{DeviceHost}/OperationMode/Mode"], ct);
|
|
|
|
snapshots.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.Good);
|
|
snapshots[0].Value!.ToString().ShouldStartWith("O0042");
|
|
Convert.ToInt32(snapshots[1].Value).ShouldBe(42);
|
|
Convert.ToInt32(snapshots[2].Value).ShouldBe(17);
|
|
Convert.ToInt32(snapshots[3].Value).ShouldBe(3);
|
|
}
|
|
}
|
|
|
|
/// <summary>Verifies that timer data populates via the wire backend.</summary>
|
|
[Fact]
|
|
public async Task Timers_populate_via_wire_backend()
|
|
{
|
|
if (_fx.SkipReason is not null) Assert.Skip(_fx.SkipReason);
|
|
var ct = TestContext.Current.CancellationToken;
|
|
|
|
await _fx.LoadProfileAsync("FWLIB64", ct);
|
|
await _fx.PatchStateAsync(new
|
|
{
|
|
axis_names = new[] { "X" },
|
|
timers = new
|
|
{
|
|
power_on = 3600,
|
|
operating = 7200,
|
|
cutting = 1800,
|
|
cycle = 120,
|
|
},
|
|
}, ct);
|
|
|
|
var driver = new FocasDriver(new FocasDriverOptions
|
|
{
|
|
Devices = [new FocasDeviceOptions(DeviceHost)],
|
|
RawTags = [],
|
|
Probe = new FocasProbeOptions { Enabled = false },
|
|
FixedTree = new FocasFixedTreeOptions
|
|
{
|
|
Enabled = true,
|
|
PollInterval = TimeSpan.FromMilliseconds(100),
|
|
TimerPollInterval = TimeSpan.FromMilliseconds(200),
|
|
ProgramPollInterval = TimeSpan.Zero,
|
|
},
|
|
}, driverInstanceId: "focas-wire-timers", clientFactory: new WireFocasClientFactory());
|
|
|
|
await using (driver)
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
|
|
await WaitFor(() =>
|
|
{
|
|
var state = driver.GetDeviceState(DeviceHost);
|
|
return state is not null && state.LastTimers.Count == 4;
|
|
}, TimeSpan.FromSeconds(5));
|
|
|
|
var snapshots = await driver.ReadAsync(
|
|
[$"{DeviceHost}/Timers/PowerOnSeconds",
|
|
$"{DeviceHost}/Timers/OperatingSeconds",
|
|
$"{DeviceHost}/Timers/CuttingSeconds",
|
|
$"{DeviceHost}/Timers/CycleSeconds"], ct);
|
|
|
|
snapshots.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.Good);
|
|
Convert.ToDouble(snapshots[0].Value).ShouldBe(3600.0, tolerance: 1);
|
|
Convert.ToDouble(snapshots[1].Value).ShouldBe(7200.0, tolerance: 1);
|
|
Convert.ToDouble(snapshots[2].Value).ShouldBe(1800.0, tolerance: 1);
|
|
Convert.ToDouble(snapshots[3].Value).ShouldBe(120.0, tolerance: 1);
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Verifies that the spindle load and motor-speed meters populate via the wire backend as
|
|
/// percentages of full scale (the mock serves 1/16384-of-full-scale counts, as a real
|
|
/// 31i-B does): S1 load 56% / speed 3200 of 6000 rpm = 53.3%, S2 load 12% / 1800 of 4500 = 40%.
|
|
/// </summary>
|
|
[Fact]
|
|
public async Task Spindle_load_and_motor_speed_populate_via_wire_backend()
|
|
{
|
|
if (_fx.SkipReason is not null) Assert.Skip(_fx.SkipReason);
|
|
var ct = TestContext.Current.CancellationToken;
|
|
|
|
await _fx.LoadProfileAsync("FWLIB64", ct);
|
|
await _fx.PatchStateAsync(new
|
|
{
|
|
axis_names = new[] { "X" },
|
|
spindle_names = new[] { "S1", "S2" },
|
|
spindle = new
|
|
{
|
|
load = new object[]
|
|
{
|
|
new { name = "S1", load = 56, speed = 3200 },
|
|
new { name = "S2", load = 12, speed = 1800 },
|
|
},
|
|
max_rpm = new[] { 6000, 4500 },
|
|
},
|
|
rddynamic2 = new
|
|
{
|
|
axis = 1, alarm = 0, prgnum = 1, prgmnum = 1, seqnum = 1,
|
|
actf = 0, acts = 0,
|
|
pos = new { absolute = 0, machine = 0, relative = 0, distance = 0 },
|
|
},
|
|
}, ct);
|
|
|
|
var driver = new FocasDriver(new FocasDriverOptions
|
|
{
|
|
Devices = [new FocasDeviceOptions(DeviceHost)],
|
|
RawTags = [],
|
|
Probe = new FocasProbeOptions { Enabled = false },
|
|
FixedTree = new FocasFixedTreeOptions
|
|
{
|
|
Enabled = true,
|
|
PollInterval = TimeSpan.FromMilliseconds(100),
|
|
ProgramPollInterval = TimeSpan.Zero,
|
|
TimerPollInterval = TimeSpan.Zero,
|
|
},
|
|
}, driverInstanceId: "focas-wire-spindle", clientFactory: new WireFocasClientFactory());
|
|
|
|
await using (driver)
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
|
|
await WaitFor(() =>
|
|
{
|
|
var state = driver.GetDeviceState(DeviceHost);
|
|
return state?.FixedTreeCache is { Capabilities.SpindleLoad: true, Capabilities.SpindleMotorSpeed: true }
|
|
&& state.LastSpindleLoads.Count >= 2;
|
|
}, TimeSpan.FromSeconds(5));
|
|
|
|
var snapshots = await driver.ReadAsync(
|
|
[$"{DeviceHost}/Spindle/S1/Load",
|
|
$"{DeviceHost}/Spindle/S1/MotorSpeedPct",
|
|
$"{DeviceHost}/Spindle/S2/Load",
|
|
$"{DeviceHost}/Spindle/S2/MotorSpeedPct"], ct);
|
|
|
|
snapshots.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.Good);
|
|
Convert.ToDouble(snapshots[0].Value).ShouldBe(56.0, tolerance: 0.01);
|
|
Convert.ToDouble(snapshots[1].Value).ShouldBe(3200 * 100.0 / 6000, tolerance: 0.01);
|
|
Convert.ToDouble(snapshots[2].Value).ShouldBe(12.0, tolerance: 0.01);
|
|
Convert.ToDouble(snapshots[3].Value).ShouldBe(40.0, tolerance: 0.01);
|
|
}
|
|
}
|
|
|
|
private static async Task WaitFor(Func<bool> pred, TimeSpan timeout)
|
|
{
|
|
var deadline = DateTime.UtcNow + timeout;
|
|
while (DateTime.UtcNow < deadline)
|
|
{
|
|
if (pred()) return;
|
|
await Task.Delay(50);
|
|
}
|
|
}
|
|
}
|