Joseph Doherty 33054c3275 docs: drop dangling FOCAS refs + link unreferenced v2 design docs
- docs/drivers/FOCAS.md and docs/v2/implementation/focas-wire-protocol.md
  pointed at focas-deployment.md and focas-simulator-plan.md, both of
  which were untracked drafts that have since been removed. Drop the
  refs (the wire-protocol companion now stands on its own; deployment
  guidance lives inline in the FOCAS driver doc).
- Link the orphan v2 design docs from docs/README.md (multi-host
  dispatch, v2 release readiness, the historical lmx-followups tracker)
  and from modbus-test-plan.md (s7.md, mitsubishi.md per-family quirk
  catalogs, sibling to dl205.md).

Surfaced by the doc audit; no content changes.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-30 09:42:28 -04:00
..
ADR-002 — driver-vs-virtual dispatch: DriverNodeManager routes reads/writes/subscriptions across driver tags and virtual (scripted) tags via a single NodeManager with a NodeSource tag on NodeScopeResolver's output. Locks the architecture decision Phase 7 Stream G was going to have to make anyway — documenting it up front so the stream implementation can reference the chosen shape instead of rediscovering it. Option A (separate VirtualTagNodeManager sibling) rejected because shared Equipment folders owning both driver and virtual children would force two NodeManagers to fight for ownership on every Equipment node — the common case, not the exception — defeating the separation. Option C (virtual engine registers as a synthetic IDriver through DriverTypeRegistry) rejected because DriverInstance shape is wrong for scripting config (no DriverType, no HostAddress, no connectivity probe, no NSSM wrapper), IDriver.InitializeAsync semantics don't match script compilation, Polly resilience wrappers calibrated for network calls would either passthrough pointlessly or tune wrong, and Admin UI would need special-casing everywhere to hide fields that don't apply. Option B (single DriverNodeManager, NodeScopeResolver returns NodeSource enum alongside ScopeId, dispatch branches on source) accepted because it preserves one address-space tree with one walker, ACL binding works identically for both kinds, Phase 6.1 resilience + Phase 6.2 audit apply uniformly to the driver branch without needing Roslyn analyzer exemptions, and adding future source kinds is a single-enum-case addition. NodeScopeResolver.Resolve returns NodeScope(ScopeId, NodeSource, DriverInstanceId?, VirtualTagId?); DriverNodeManager pattern-matches on scope.Source and routes to either the driver dictionary or IVirtualTagEngine. OPC UA client writes to a virtual node return BadUserAccessDenied before the dispatch branch because Phase 7 decision #6 restricts virtual-tag writes to scripts via ctx.SetVirtualTag. Dispatch test coverage specified for Stream G.4: mixed Equipment folders browsing correctly, read routing per source kind, subscription fan-out across both kinds, the BadUserAccessDenied guard on virtual writes, and script-driven writes firing subscription notifications. ADR-001's walker gains the VirtualTag config-DB table as an additional input channel alongside Tag; NodeScopeResolver's ScopeId return stays unchanged so Phase 6.2's ACL trie needs no modification. Consequences flagged: whether IVirtualTagEngine lives in Core.Abstractions vs Phase 7's Core.VirtualTags project, and whether future server-side methods on virtual nodes would route through this dispatch, both marked out-of-scope for ADR-002.
2026-04-20 16:08:01 -04:00
Phase 2 official close-out. Closes task #209. The 2026-04-18 exit-gate-phase-2-final.md captured Phase 2 state at PR 2 merge — four High/Medium adversarial findings still OPEN, Historian port + alarm subsystem + v1 archive deletion all deferred. Since then: PR 4 closed all four findings end-to-end (High 1 Read subscription-leak, High 2 no reconnect loop, Medium 3 SubscribeAsync doesn't push frames, Medium 4 WriteValuesAsync doesn't await OnWriteComplete — mapped + resolved inline in the new doc), PR 12 landed the richer historian quality mapper, PR 13 shipped GalaxyRuntimeProbeManager with per-Platform/AppEngine ScanState subscriptions + StateChanged events forwarded through the existing OnHostStatusChanged IPC frame, PR 14 wired the alarm subsystem (GalaxyAlarmTracker advising the four alarm-state attributes per IsAlarm=true attribute, raising AlarmTransition events forwarded through OnAlarmEvent IPC frames), Phase 3 PR 18 deleted the v1 source trees, and PR 61 closed V1_ARCHIVE_STATUS.md. Phase 2 is functionally done; this commit is the bookkeeping pass. New exit-gate-phase-2-closed.md at docs/v2/implementation/ — five-stream status table (A/B/C/D/E all complete with the specific close commits named), full resolution table for every 2026-04-18 adversarial finding mapped to the PR 4 resolution, cross-cutting deferrals table marking every one resolved (Historian SDK plugin port → done, subscription push frames → done under Medium 3, Historian-backed HistoryRead → done, alarm subsystem wire-up → done, reconnect-without-recycle → done under High 2, v1 archive deletion → done). Fresh 2026-04-20 test baseline captured from the current v2 tip: 1844 passing + 29 infra-gated skips across 21 test projects, including the net48 x86 Galaxy.Host.Tests suite (107 pass) that exercises the MXAccess COM path on the dev box. Flake observed — Configuration.Tests 70/71 on first full-solution run, 71/71 on retry; logged as a known non-stable flake rather than chased because it did not reproduce. The prior exit-gate-phase-2-final.md is kept in place (historical record of the 2026-04-18 snapshot) but gets a superseded-by banner at the top pointing at the new close-out doc so future readers land on current status first. docs/v2/plan.md Phase 2 section header gains the CLOSED 2026-04-20 marker + a link to the close-out doc so the top-level plan index reflects reality. "What Phase 2 closed means for Phase 3 and later" section in the new doc captures the downstream contract: Galaxy now runs as a first-class v2 driver with the same capability-interface shape as Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient; no v1 code path remains; the 2026-04-13 stability findings persist as named regression tests under tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/StabilityFindingsRegressionTests.cs so any future refactor reintroducing them trips the test. "Outstanding — not Phase 2 blockers" section lists the four pending non-Phase-2 tasks (#177, #194, #195, #199) so nobody mistakes them for Phase 2 tail work.
2026-04-20 02:00:35 -04:00
Phase 2 official close-out. Closes task #209. The 2026-04-18 exit-gate-phase-2-final.md captured Phase 2 state at PR 2 merge — four High/Medium adversarial findings still OPEN, Historian port + alarm subsystem + v1 archive deletion all deferred. Since then: PR 4 closed all four findings end-to-end (High 1 Read subscription-leak, High 2 no reconnect loop, Medium 3 SubscribeAsync doesn't push frames, Medium 4 WriteValuesAsync doesn't await OnWriteComplete — mapped + resolved inline in the new doc), PR 12 landed the richer historian quality mapper, PR 13 shipped GalaxyRuntimeProbeManager with per-Platform/AppEngine ScanState subscriptions + StateChanged events forwarded through the existing OnHostStatusChanged IPC frame, PR 14 wired the alarm subsystem (GalaxyAlarmTracker advising the four alarm-state attributes per IsAlarm=true attribute, raising AlarmTransition events forwarded through OnAlarmEvent IPC frames), Phase 3 PR 18 deleted the v1 source trees, and PR 61 closed V1_ARCHIVE_STATUS.md. Phase 2 is functionally done; this commit is the bookkeeping pass. New exit-gate-phase-2-closed.md at docs/v2/implementation/ — five-stream status table (A/B/C/D/E all complete with the specific close commits named), full resolution table for every 2026-04-18 adversarial finding mapped to the PR 4 resolution, cross-cutting deferrals table marking every one resolved (Historian SDK plugin port → done, subscription push frames → done under Medium 3, Historian-backed HistoryRead → done, alarm subsystem wire-up → done, reconnect-without-recycle → done under High 2, v1 archive deletion → done). Fresh 2026-04-20 test baseline captured from the current v2 tip: 1844 passing + 29 infra-gated skips across 21 test projects, including the net48 x86 Galaxy.Host.Tests suite (107 pass) that exercises the MXAccess COM path on the dev box. Flake observed — Configuration.Tests 70/71 on first full-solution run, 71/71 on retry; logged as a known non-stable flake rather than chased because it did not reproduce. The prior exit-gate-phase-2-final.md is kept in place (historical record of the 2026-04-18 snapshot) but gets a superseded-by banner at the top pointing at the new close-out doc so future readers land on current status first. docs/v2/plan.md Phase 2 section header gains the CLOSED 2026-04-20 marker + a link to the close-out doc so the top-level plan index reflects reality. "What Phase 2 closed means for Phase 3 and later" section in the new doc captures the downstream contract: Galaxy now runs as a first-class v2 driver with the same capability-interface shape as Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient; no v1 code path remains; the 2026-04-13 stability findings persist as named regression tests under tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/StabilityFindingsRegressionTests.cs so any future refactor reintroducing them trips the test. "Outstanding — not Phase 2 blockers" section lists the four pending non-Phase-2 tasks (#177, #194, #195, #199) so nobody mistakes them for Phase 2 tail work.
2026-04-20 02:00:35 -04:00
Phase 2 — port MXAccess COM client to Galaxy.Host + MxAccessGalaxyBackend (3rd IGalaxyBackend) + live MXAccess smoke + Phase 2 exit-gate doc + adversarial review. The full Galaxy data-plane now flows through the v2 IPC topology end-to-end against live ArchestrA.MxAccess.dll, on this dev box, with 30/30 Host tests + 9/9 Proxy tests + 963/963 solution tests passing alongside the unchanged 494 v1 IntegrationTests baseline. Backend/MxAccess/Vtq is a focused port of v1's Vtq value-timestamp-quality DTO. Backend/MxAccess/IMxProxy abstracts LMXProxyServer (port of v1's IMxProxy with the same Register/Unregister/AddItem/RemoveItem/AdviseSupervisory/UnAdviseSupervisory/Write surface + OnDataChange + OnWriteComplete events); MxProxyAdapter is the concrete COM-backed implementation that does Marshal.ReleaseComObject-loop on Unregister, must be constructed on an STA thread. Backend/MxAccess/MxAccessClient is the focused port of v1's MxAccessClient partials — Connect/Disconnect/Read/Write/Subscribe/Unsubscribe through the new Sta/StaPump (the real Win32 GetMessage pump from the previous commit), ConcurrentDictionary handle tracking, OnDataChange event marshalling to per-tag callbacks, ReadAsync implemented as the canonical subscribe → first-OnDataChange → unsubscribe one-shot pattern. Galaxy.Host csproj flipped to x86 PlatformTarget + Prefer32Bit=true with the ArchestrA.MxAccess HintPath ..\..\lib\ArchestrA.MxAccess.dll reference (lib/ already contains the production DLL). Backend/MxAccessGalaxyBackend is the third IGalaxyBackend implementation (alongside StubGalaxyBackend and DbBackedGalaxyBackend): combines GalaxyRepository (Discover) with MxAccessClient (Read/Write/Subscribe), MessagePack-deserializes inbound write values, MessagePack-serializes outbound read values into ValueBytes, decodes ArrayDimension/SecurityClassification/category_id with the same v1 mapping. Program.cs selects between stub|db|mxaccess via OTOPCUA_GALAXY_BACKEND env var (default = mxaccess); OTOPCUA_GALAXY_ZB_CONN overrides the ZB connection string; OTOPCUA_GALAXY_CLIENT_NAME sets the Wonderware client identity; the StaPump and MxAccessClient lifecycles are tied to the server.RunAsync try/finally so a clean Ctrl+C tears down the COM proxy via Marshal.ReleaseComObject before the pump's WM_QUIT. Live MXAccess smoke tests (MxAccessLiveSmokeTests, net48 x86) — skipped when ZB unreachable or aaBootstrap not running, otherwise verify (1) MxAccessClient.ConnectAsync returns a positive LMXProxyServer handle on the StaPump, (2) MxAccessGalaxyBackend.OpenSession + Discover returns at least one gobject with attributes, (3) MxAccessGalaxyBackend.ReadValues against the first discovered attribute returns a response with the correct TagReference shape (value + quality vary by what's running, so we don't assert specific values). All 3 pass on this dev box. EndToEndIpcTests + IpcHandshakeIntegrationTests moved from Galaxy.Proxy.Tests (net10) to Galaxy.Host.Tests (net48 x86) — the previous test placement silently dropped them at xUnit discovery because Host became net48 x86 and net10 process can't load it. Rewritten to use Shared's FrameReader/FrameWriter directly instead of going through Proxy's GalaxyIpcClient (functionally equivalent — same wire protocol, framing primitives + dispatcher are the production code path verbatim). 7 IPC tests now run cleanly: Hello+heartbeat round-trip, wrong-secret rejection, OpenSession session-id assignment, Discover error-response surfacing, WriteValues per-tag bad status, Subscribe id assignment, Recycle grace window. Phase 2 exit-gate doc (docs/v2/implementation/exit-gate-phase-2.md) supersedes the partial-exit doc with the as-built state — Streams A/B/C complete; D/E gated only on the legacy-Host removal + parity-test rewrite cycle that fundamentally requires multi-day debug iteration; full adversarial-review section ranking 8 findings (2 high, 3 medium, 3 low) all explicitly deferred to Stream D/E or v2.1 with rationale; Stream-D removal checklist gives the next-session entry point with two policy options for the 494 v1 tests (rewrite-to-use-Proxy vs archive-and-write-smaller-v2-parity-suite). Cannot one-shot Stream D.1 in any single session because deleting OtOpcUa.Host requires the v1 IntegrationTests cycle to be retargeted first; that's the structural blocker, not "needs more code" — and the plan itself budgets 3-4 weeks for it.
2026-04-18 00:23:24 -04:00
Phase 2 Streams A+B+C feature-complete — real Win32 pump, all 9 IDriver capabilities, end-to-end IPC dispatch. Streams D+E remain (Galaxy MXAccess code lift + parity-debug cycle, plan-budgeted 3-4 weeks). The 494 v1 IntegrationTests still pass — legacy OtOpcUa.Host untouched. StaPump replaces the BlockingCollection placeholder with a real Win32 message pump lifted from v1 StaComThread per CLAUDE.md "Reference Implementation": dedicated STA Thread with SetApartmentState(STA), GetMessage/PostThreadMessage/PeekMessage/TranslateMessage/DispatchMessage/PostQuitMessage P/Invoke, WM_APP=0x8000 for work-item dispatch, WM_APP+1 for graceful-drain → PostQuitMessage, peek-pm-noremove on entry to force the system to create the thread message queue before signalling Started, IsResponsiveAsync probe still no-op-round-trips through PostThreadMessage so the wedge detection works against the real pump. Concurrent ConcurrentQueue<WorkItem> drains on every WM_APP; fault path on dispose drains-and-faults all pending work-item TCSes with InvalidOperationException("STA pump has exited"). All three StaPumpTests pass against the real pump (apartment state STA, healthy probe true, wedged probe false). GalaxyProxyDriver now implements every Phase 2 Stream C capability — IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe — each forwarding through the matching IPC contract. ReadAsync preserves request order even when the Host returns out-of-order values; WriteAsync MessagePack-serializes the value into ValueBytes; SubscribeAsync wraps SubscriptionId in a GalaxySubscriptionHandle record; UnsubscribeAsync uses the new SendOneWayAsync helper on GalaxyIpcClient (fire-and-forget but still gated through the call-semaphore so it doesn't interleave with CallAsync); AlarmSubscribe is one-way and the Host pushes events back via OnAlarmEvent; ReadProcessedAsync short-circuits to NotSupportedException (Galaxy historian only does raw); IRediscoverable's OnRediscoveryNeeded fires when the Host pushes a deploy-watermark notification; IHostConnectivityProbe.GetHostStatuses() snapshots and OnHostStatusChanged fires on Running↔Stopped/Faulted transitions, with IpcHostConnectivityStatus aliased to disambiguate from the Core.Abstractions namespace's same-named type. Internal RaiseDataChange/RaiseAlarmEvent/RaiseRediscoveryNeeded/OnHostConnectivityUpdate methods are the entry points the IPC client will invoke when push frames arrive. Host side: new Backend/IGalaxyBackend interface defines the seam between IPC dispatch and the live MXAccess code (so the dispatcher is unit-testable against an in-memory mock without needing live Galaxy); Backend/StubGalaxyBackend returns success for OpenSession/CloseSession/Subscribe/Unsubscribe/AlarmSubscribe/AlarmAck/Recycle and a recognizable "stub: MXAccess code lift pending (Phase 2 Task B.1)"-tagged error for Discover/ReadValues/WriteValues/HistoryRead — keeps the IPC end-to-end testable today and gives the parity team a clear seam to slot the real implementation into; Ipc/GalaxyFrameHandler is the new real dispatcher (replaces StubFrameHandler in Program.cs) — switch on MessageKind, deserialize the matching contract, await backend method, write the response (one-way for Unsubscribe/AlarmSubscribe/AlarmAck/CloseSession), heartbeat handled inline so liveness still works if the backend is sick, exceptions caught and surfaced as ErrorResponse with code "handler-exception" so the Proxy raises GalaxyIpcException instead of disconnecting. End-to-end IPC integration test (EndToEndIpcTests) drives every operation through the full stack — Initialize → Read → Write → Subscribe → Unsubscribe → SubscribeAlarms → AlarmAck → ReadRaw → ReadProcessed (short-circuit) — proving the wire protocol, dispatcher, capability forwarding, and one-way semantics agree end-to-end. Skipped on Windows administrator shells per the same PipeAcl-denies-Administrators reasoning the IpcHandshakeIntegrationTests use. Full solution 952 pass / 1 pre-existing Phase 0 baseline. Phase 2 evidence doc updated: status header now reads "Streams A+B+C complete... Streams D+E remain — gated only on the iterative Galaxy code lift + parity-debug cycle"; new Update 2026-04-17 (later) callout enumerates the upgrade with explicit "what's left for the Phase 2 exit gate" — replace StubGalaxyBackend with a MxAccessClient-backed implementation calling on the StaPump, then run the v1 IntegrationTests against the v2 topology and iterate on parity defects until green, then delete legacy OtOpcUa.Host.
2026-04-17 23:02:00 -04:00
Phase 2 Stream D progress — non-destructive deliverables: appsettings → DriverConfig migration script, two-service Windows installer scripts, process-spawn cross-FX parity test, Stream D removal procedure doc with both Option A (rewrite 494 v1 tests) and Option B (archive + new v2 E2E suite) spelled out step-by-step. Cannot one-shot the actual legacy-Host deletion in any unattended session — explained in the procedure doc; the parity-defect debug cycle is intrinsically interactive (each iteration requires inspecting a v1↔v2 diff and deciding if it's a legitimate v2 improvement or a regression, then either widening the assertion or fixing the v2 code), and git rm -r src/ZB.MOM.WW.OtOpcUa.Host is destructive enough to need explicit operator authorization on a real PR review. scripts/migration/Migrate-AppSettings-To-DriverConfig.ps1 takes a v1 appsettings.json and emits the v2 DriverInstance.DriverConfig JSON blob (MxAccess/Database/Historian sections) ready to upsert into the central Configuration DB; null-leaf stripping; -DryRun mode; smoke-tested against the dev appsettings.json and produces the expected three-section ordered-dictionary output. scripts/install/Install-Services.ps1 registers the two v2 services with sc.exe — OtOpcUaGalaxyHost first (net48 x86 EXE with OTOPCUA_GALAXY_PIPE/OTOPCUA_ALLOWED_SID/OTOPCUA_GALAXY_SECRET/OTOPCUA_GALAXY_BACKEND/OTOPCUA_GALAXY_ZB_CONN/OTOPCUA_GALAXY_CLIENT_NAME env vars set via HKLM:\SYSTEM\CurrentControlSet\Services\OtOpcUaGalaxyHost\Environment registry), then OtOpcUa with depend=OtOpcUaGalaxyHost; resolves down-level account names to SID for the IPC ACL; generates a fresh 32-byte base64 shared secret per install if not supplied (kept out of registry — operators record offline for service rebinding scenarios); echoes start commands. scripts/install/Uninstall-Services.ps1 stops + removes both services. tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy.Tests/HostSubprocessParityTests.cs is the production-shape parity test — Proxy (.NET 10) spawns the actual OtOpcUa.Driver.Galaxy.Host.exe (net48 x86) as a subprocess via Process.Start with backend=db env vars, connects via real named pipe, calls Discover, asserts at least one Galaxy gobject comes back. Skipped when running as Administrator (PipeAcl denies admins, same guard as other IPC integration tests), when the Host EXE hasn't been built, or when the ZB SQL endpoint is unreachable. This is the cross-FX integration that the parity suite genuinely needs — the previous IPC tests all ran in-process; this one validates the production deployment topology where Proxy and Host are separate processes communicating only over the named pipe. docs/v2/implementation/stream-d-removal-procedure.md is the next-session playbook: Option A (rewrite 494 v1 tests via a ProxyMxAccessClientAdapter that implements v1's IMxAccessClient by forwarding to GalaxyProxyDriver — Vtq↔DataValueSnapshot, Quality↔StatusCode, OnTagValueChanged↔OnDataChange mapping; 3-5 days, full coverage), Option B (rename OtOpcUa.Tests → OtOpcUa.Tests.v1Archive with [Trait("Category", "v1Archive")] for opt-in CI runs; new OtOpcUa.Driver.Galaxy.E2E test project with 10-20 representative tests via the HostSubprocessParityTests pattern; 1-2 days, accreted coverage); deletion checklist with eight pre-conditions, ten ordered steps, and a rollback path (git revert restores the legacy Host alongside the v2 stack — both topologies remain installable until the downstream consumer cutover). Full solution 964 pass / 1 pre-existing Phase 0 baseline; the 494 v1 IntegrationTests + 6 v1 IntegrationTests-net48 still pass because legacy OtOpcUa.Host stays untouched until an interactive session executes the procedure doc.
2026-04-18 00:38:44 -04:00