Files
lmxopcua/docs/v2/implementation
Joseph Doherty 2a6c9828e4 Confirm the v2 driver list as fixed (decision #128) and remove the Equipment Protocol Survey from the v2 prerequisites — the seven committed drivers (Modbus TCP including DL205, AB CIP, AB Legacy, S7, TwinCAT, FOCAS, OPC UA Client) plus Galaxy/MXAccess are confirmed by direct knowledge of the equipment estate (TwinCAT and AB Legacy specifically called out by the OtOpcUa team based on known Beckhoff installations and SLC/MicroLogix legacy equipment); the survey may still inform long-tail driver scoping and per-site capacity planning but adding/removing drivers from the v2 implementation list is now out of scope. Phase-1 implementation doc loses the survey row from its Out-of-Scope table.
Add Phase 2 detailed implementation plan (docs/v2/implementation/phase-2-galaxy-out-of-process.md) covering the largest refactor phase — moving Galaxy from the legacy in-process OtOpcUa.Host project into the Tier C out-of-process topology specified in driver-stability.md. Five work streams: A. Driver.Galaxy.Shared (.NET Standard 2.0 IPC contracts using MessagePack with hello-message version negotiation), B. Driver.Galaxy.Host (.NET 4.8 x86 separate Windows service that owns MxAccessBridge / GalaxyRepository / alarm tracking / GalaxyRuntimeProbeManager / Wonderware Historian SDK / STA thread + Win32 message pump with health probe / MxAccessHandle SafeHandle for COM lifetime / subscription registry with cross-host quality scoping / named-pipe IPC server with mandatory ACL + caller SID verification + per-process shared secret / memory watchdog with Galaxy-specific 1.5x baseline + 200MB floor + 1.5GB ceiling / recycle policy with 15s grace + WM_QUIT escalation to hard-exit / post-mortem MMF writer / Driver.Galaxy.FaultShim test-only assembly), C. Driver.Galaxy.Proxy (.NET 10 in-process driver implementing every capability interface, heartbeat sender on dedicated channel with 2s/3-miss tolerance, supervisor with respawn-with-backoff and crash-loop circuit breaker with escalating cooldown 1h/4h/24h, address space build via IAddressSpaceBuilder producing byte-equivalent v1 output), D. Retire legacy OtOpcUa.Host (delete from solution, two-service Windows installer, migrate appsettings.json Galaxy sections to central DB DriverConfig blob), E. Parity validation (v1 IntegrationTests pass count = baseline failures = 0, scripted Client.CLI walkthrough output diff vs v1 only differs in timestamps/latency, four named regression tests for the 2026-04-13 stability findings). Compliance script verifies all eight Tier C cross-cutting protections have named passing tests. Decision #128 captures the survey-removal; cross-references added to plan.md Reference Documents and overview.md phase index.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-17 11:35:04 -04:00
..
Add Phase 0 + Phase 1 detailed implementation plans under docs/v2/implementation/ with a phase-gate model so the work can be verified for compliance to the v2 design as it lands. Three-gate structure per phase (entry / mid / exit) with explicit compliance-check categories: schema compliance (live DB introspected against config-db-schema.md DDL via xUnit), decision compliance (every decision number cited in the phase doc must have at least one code/test citation in the codebase, verified via git grep), visual compliance (Admin UI screenshots reviewed side-by-side against ScadaLink CentralUI's equivalent screens), behavioral compliance (per-phase end-to-end smoke test that always passes at exit, never "known broken fix later"), stability compliance (cross-cutting protections from driver-stability.md wired up and regression-tested for Tier C drivers), and documentation compliance (any deviation from v2 design docs reflected back as decision-log updates with explicit "supersedes" notes). Exit gate requires two-reviewer signoff and an exit-gate-{phase}.md record; silent deviation is the failure mode the gates exist to make impossible to ship. Phase 0 doc covers the mechanical LmxOpcUa → OtOpcUa rename with 9 tasks, 7 compliance checks, and a completion checklist that gates on baseline test count parity. Phase 1 doc covers the largest greenfield phase — 5 work streams (Core.Abstractions, Configuration project with EF Core schema + stored procs + LiteDB cache + generation-diff applier, Core with GenericDriverNodeManager rename + IAddressSpaceBuilder + driver isolation, Server with Microsoft.Extensions.Hosting replacing TopShelf + credential-bound bootstrap, Admin Blazor Server app mirroring ScadaLink CentralUI verbatim with LDAP cookie auth + draft/diff/publish workflow + UNS structure management + equipment CRUD + release-reservation and merge-equipment operator flows) — with task-level acceptance criteria, a 14-step end-to-end smoke test, and decision citation requirements for #1-125. New decisions #126-127 capture the gate model and per-phase doc structure. Cross-references added to plan.md Reference Documents section.
2026-04-17 11:25:09 -04:00