Joseph Doherty 3a4ed8ddb5 fix(mesh): break Phase 6 boot-crash — cluster-redundancy singleton scope must not resolve IClusterRoleInfo eagerly
Phase 6 wired the re-homed redundancy singleton in Program.cs as
`WithOtOpcUaClusterRedundancySingleton(sp.GetRequiredService<IClusterRoleInfo>())`
inside the AddAkka configurator lambda. That lambda runs WHILE the ActorSystem is
being built, but ClusterRoleInfo depends on the ActorSystem (it is a live
Cluster.State view) — so resolving it there recurses into ActorSystem construction
and every node dies at boot with StackOverflowException. It compiles cleanly (a
runtime DI cycle) and RedundancyStateSingletonRehomeTests passed a hand-built
FakeClusterRoleInfo straight into the extension, mocking around the composition-root
line that overflows. The docker-dev live gate caught it on first boot.

Derive the singleton's cluster-role scope from AkkaClusterOptions (pure config, no
ActorSystem) instead: BuildClusterRedundancySingletonOptions / the extension now take
AkkaClusterOptions and compute Role = Roles.FirstOrDefault(IsClusterRole) ?? driver —
identical to ClusterRoleInfo.ClusterRole, which derives from the same config. Program.cs
passes IOptions<AkkaClusterOptions>.Value, which has no ActorSystem dependency.

Live-verified: rebuilt image boots with zero stack-overflow lines, cluster singletons
form per mesh. 5/5 rehome tests pass; Host builds clean.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 06:54:14 -04:00
..