Joseph Doherty a9b585ac5b Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward-
bridge) only proved driver-write → server-read. It missed:

 - OPC UA write → server → driver → PLC (the reverse direction)
 - server-side data-change notifications actually firing (a stale
   subscription can still let a read-after-the-fact return the new
   value and look fine)

Extend _common.ps1 with two helpers:

 - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s ->
   driver CLI read the PLC side, assert equality.
 - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the
   background with --duration N, settle 2s, driver-side write, wait for
   the subscription window to close, assert captured stdout contains
   the new value.

Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 /
test-focas / test-twincat after the existing forward-bridge stage.
Update README to describe the five-stage design + note that the
published NodeId must be writable for stages 4 + 5.

Also prepend UTF-8 BOM to every script in scripts/e2e so Windows
PowerShell 5.1 parsers agree on em-dash byte sequences the way
PowerShell 7 already does. The scripts still #Requires -Version 7.0 —
the BOM is purely defensive for IDE / CI step parsers.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 10:08:52 -04:00

100 lines
3.4 KiB
PowerShell

#Requires -Version 7.0
<#
.SYNOPSIS
End-to-end CLI test for the AB Legacy (PCCC) driver.
.DESCRIPTION
**KNOWN-BROKEN upstream (ab_server PCCC dispatcher gap, verified 2026-04-21).**
Works against real SLC / MicroLogix / PLC-5 hardware or a RSEmulate 500
golden-box. Against the Docker ab_server the tests deliberately skip —
same gate as tests/.../AbLegacy.IntegrationTests (AB_LEGACY_TRUST_WIRE=1).
Five assertions: probe / driver-loopback / forward-bridge / reverse-bridge /
subscribe-sees-change.
.PARAMETER Gateway
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0.
.PARAMETER PlcType
Slc500 / MicroLogix / Plc5 / LogixPccc (default Slc500).
.PARAMETER Address
PCCC address to exercise. Default N7:5.
.PARAMETER OpcUaUrl
OtOpcUa server endpoint.
.PARAMETER BridgeNodeId
NodeId at which the server publishes the Address.
#>
param(
[string]$Gateway = "ab://127.0.0.1/1,0",
[string]$PlcType = "Slc500",
[string]$Address = "N7:5",
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
[Parameter(Mandatory)] [string]$BridgeNodeId
)
$ErrorActionPreference = "Stop"
. "$PSScriptRoot/_common.ps1"
# Skip-gate: the driver CLI's underlying AbLegacyServerFixture-equivalent
# check — operators point at real hardware by setting AB_LEGACY_TRUST_WIRE=1.
# Without the opt-in we skip (don't run against the known-broken ab_server).
if (-not ($env:AB_LEGACY_TRUST_WIRE -eq "1" -or $env:AB_LEGACY_TRUST_WIRE -eq "true")) {
Write-Skip "AB_LEGACY_TRUST_WIRE not set — skipping (ab_server PCCC is upstream-broken; set =1 against real hardware / RSEmulate)."
exit 0
}
$abLegacyCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli" `
-ExeName "otopcua-ablegacy-cli"
$opcUaCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
-ExeName "otopcua-cli"
$commonAbLegacy = @("-g", $Gateway, "-P", $PlcType)
$results = @()
$results += Test-Probe `
-Cli $abLegacyCli `
-ProbeArgs (@("probe") + $commonAbLegacy + @("-a", "N7:0"))
$writeValue = Get-Random -Minimum 1 -Maximum 9999
$results += Test-DriverLoopback `
-Cli $abLegacyCli `
-WriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $writeValue)) `
-ReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
-ExpectedValue "$writeValue"
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
$results += Test-ServerBridge `
-DriverCli $abLegacyCli `
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $bridgeValue)) `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-ExpectedValue "$bridgeValue"
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
$results += Test-OpcUaWriteBridge `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $abLegacyCli `
-DriverReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
-ExpectedValue "$reverseValue"
$subValue = Get-Random -Minimum 30000 -Maximum 32766
$results += Test-SubscribeSeesChange `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $abLegacyCli `
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $subValue)) `
-ExpectedValue "$subValue"
Write-Summary -Title "AB Legacy e2e" -Results $results
if ($results | Where-Object { -not $_.Passed }) { exit 1 }