The two most-edited entities for daily operator workflows. Both follow the
same single-page edit-or-create pattern from batches 1 + 2 with RowVersion
optimistic concurrency.
- EquipmentEdit.razor /clusters/{id}/equipment/{new|EquipmentId}
- EquipmentId is system-generated on create (decision #125): EQ-{first
12 hex chars of a new EquipmentUuid}.
- UNS line + driver instance selects are scoped to the cluster.
- All 9 OPC 40010 identification fields surfaced as an optional panel.
- MachineCode uniqueness checked client-side before EF unique index
enforces it server-side.
- TagEdit.razor /clusters/{id}/tags/{new|TagId}
- Equipment vs FolderPath input switches based on the selected
driver's namespace kind — Equipment-kind requires EquipmentId,
SystemPlatform-kind requires FolderPath (decision #110 invariant
enforced client-side; sp_ValidateDraft re-enforces server-side at
deploy).
- DataType select uses the OPC UA built-in primitive type names.
- TagConfig validated as JSON pre-flight.
ClusterEquipment + ClusterTags list pages get New / Edit affordances.