feat(adminui): F15.2 batch 3 — Equipment + Tag CRUD (operator surfaces)
The two most-edited entities for daily operator workflows. Both follow the
same single-page edit-or-create pattern from batches 1 + 2 with RowVersion
optimistic concurrency.

- EquipmentEdit.razor   /clusters/{id}/equipment/{new|EquipmentId}
  - EquipmentId is system-generated on create (decision #125): EQ-{first
    12 hex chars of a new EquipmentUuid}.
  - UNS line + driver instance selects are scoped to the cluster.
  - All 9 OPC 40010 identification fields surfaced as an optional panel.
  - MachineCode uniqueness checked client-side before EF unique index
    enforces it server-side.
- TagEdit.razor         /clusters/{id}/tags/{new|TagId}
  - Equipment vs FolderPath input switches based on the selected
    driver's namespace kind — Equipment-kind requires EquipmentId,
    SystemPlatform-kind requires FolderPath (decision #110 invariant
    enforced client-side; sp_ValidateDraft re-enforces server-side at
    deploy).
  - DataType select uses the OPC UA built-in primitive type names.
  - TagConfig validated as JSON pre-flight.

ClusterEquipment + ClusterTags list pages get New / Edit affordances.

All 9 integration tests still green.
2026-05-26 08:22:51 -04:00
..