Live investigation showed the earlier 'C2 server-gated event reads' attribution was wrong: the gateway's SQL event reader works (a source-filtered ReadEvents returns a real Galaxy-sourced event's history; a time-only ReadEvents returns 50 events). The alarm round-trip's source-filtered readback is empty only because an ad-hoc SendEvent is recorded in Runtime.dbo.Events WITHOUT a Source_Object — so reading existing Galaxy alarm/event history by source works, but round-tripping OtOpcUa's own sends by source needs the gateway's SendEvent to populate the event source. Skip message corrected. Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
262 lines
14 KiB
C#
262 lines
14 KiB
C#
using Microsoft.Extensions.Logging.Abstractions;
|
|
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.HistorianGateway.Contracts.Grpc;
|
|
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
|
using ZB.MOM.WW.OtOpcUa.Core.Abstractions.Historian;
|
|
using ZB.MOM.WW.OtOpcUa.Core.AlarmHistorian;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.Historian.Gateway.Recorder;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Historian.Gateway.Tests.Live;
|
|
|
|
/// <summary>
|
|
/// End-to-end live validation of the gateway-backed historian backend against a real, running
|
|
/// <c>ZB.MOM.WW.HistorianGateway</c> sidecar (typically <c>wonder-sql-vd03</c> on the VPN). This is
|
|
/// the validation gate the operator runs on the VPN before the Wonderware backend's retirement is
|
|
/// trusted — every path exercised here is a <em>real</em> driver component, not a fake:
|
|
/// <list type="bullet">
|
|
/// <item><see cref="GatewayHistorianDataSource"/> — the read + <c>ReadEvents</c> path.</item>
|
|
/// <item><see cref="HistorianGatewayClientAdapter"/> — the <c>EnsureTags</c> seam.</item>
|
|
/// <item><see cref="GatewayHistorianValueWriter"/> — the recorder's <c>WriteLiveValues</c> path.</item>
|
|
/// <item><see cref="GatewayAlarmHistorianWriter"/> — the alarm <c>SendEvent</c> path.</item>
|
|
/// </list>
|
|
/// <para>
|
|
/// <b>Env-gated + skip-clean.</b> Every test calls <c>Assert.Skip</c> via the fixture when the
|
|
/// suite is unconfigured / the gateway is unreachable, and again when its own required tag /
|
|
/// source env var is absent — so <c>dotnet test --filter "Category=LiveIntegration"</c> stays
|
|
/// green offline (all skip, none fail). See <see cref="GatewayLiveFixture"/> for the env vars.
|
|
/// </para>
|
|
/// <para>
|
|
/// <b>Gateway prerequisites</b> (when run on the VPN): the target gateway must run with
|
|
/// <c>RuntimeDb:Enabled=true</c> (the <c>WriteLiveValues</c> SQL path) and
|
|
/// <c>RuntimeDb:EventReadsEnabled=true</c> (the SQL <c>ReadEvents</c> path), and the API key
|
|
/// must carry the <c>historian:read</c> + <c>historian:write</c> scopes.
|
|
/// </para>
|
|
/// </summary>
|
|
[Trait("Category", "LiveIntegration")]
|
|
public sealed class GatewayLiveIntegrationTests(GatewayLiveFixture fixture) : IClassFixture<GatewayLiveFixture>
|
|
{
|
|
private readonly GatewayLiveFixture _fx = fixture;
|
|
|
|
/// <summary>
|
|
/// Read round-trip — <c>ReadRaw</c> for an existing tag over the last hour through the real
|
|
/// <see cref="GatewayHistorianDataSource"/>. Asserts the read completes without throwing and
|
|
/// returns a (possibly empty) sample set: a sparse tag legitimately has zero samples in the
|
|
/// window, so the meaningful live signal is "the gateway answered, not faulted".
|
|
/// </summary>
|
|
[Fact]
|
|
[Trait("Category", "LiveIntegration")]
|
|
public async Task Galaxy_tag_read_round_trip()
|
|
{
|
|
if (_fx.NotConfigured) Assert.Skip(_fx.SkipReason!);
|
|
if (_fx.TestTag is null)
|
|
Assert.Skip("Skipped: set HISTGW_TEST_TAG to an existing Galaxy/historian tag to run the read round-trip.");
|
|
|
|
var ct = TestContext.Current.CancellationToken;
|
|
await using var dataSource = _fx.CreateDataSource();
|
|
|
|
var endUtc = DateTime.UtcNow;
|
|
var startUtc = endUtc - TimeSpan.FromHours(1);
|
|
|
|
var result = await dataSource.ReadRawAsync(_fx.TestTag, startUtc, endUtc, maxValuesPerNode: 1000, ct);
|
|
|
|
result.ShouldNotBeNull();
|
|
result.Samples.Count.ShouldBeGreaterThanOrEqualTo(0, "a live ReadRaw must answer (zero samples is a valid sparse-tag result, not a fault)");
|
|
|
|
TestContext.Current.SendDiagnosticMessage(
|
|
$"read round-trip: ReadRaw('{_fx.TestTag}', last 1h) returned {result.Samples.Count} sample(s).");
|
|
}
|
|
|
|
/// <summary>
|
|
/// Write round-trip — <c>EnsureTags</c> (Float) → <c>WriteLiveValues</c> (a known value via the
|
|
/// real recorder writer) → <c>ReadRaw</c> the recent window and assert the written sample is
|
|
/// present. Requires the gateway running <c>RuntimeDb:Enabled=true</c> and that <c>EnsureTags</c>
|
|
/// provisioned the tag (the SQL live-write path only accepts provisioned analog tags). The write
|
|
/// value is an exact-in-float integer so the float-precision round-trip compares cleanly.
|
|
/// </summary>
|
|
[Fact]
|
|
[Trait("Category", "LiveIntegration")]
|
|
public async Task Write_then_read_on_sandbox_tag()
|
|
{
|
|
if (_fx.NotConfigured) Assert.Skip(_fx.SkipReason!);
|
|
if (_fx.WriteSandboxTag is null)
|
|
Assert.Skip("Skipped: set HISTGW_WRITE_SANDBOX_TAG to a writable Float sandbox tag (e.g. HistGW.LiveTest.Sandbox) to run the write round-trip.");
|
|
|
|
var ct = TestContext.Current.CancellationToken;
|
|
var tag = _fx.WriteSandboxTag;
|
|
|
|
// A value that is exactly representable in float32 (integer < 2^24) so the analog
|
|
// store/read round-trip is not muddied by single-precision rounding. The millisecond
|
|
// component keeps consecutive runs from colliding on the same value.
|
|
const ushort goodQuality = 192; // OPC-DA "Good" floor.
|
|
var writeUtc = DateTime.UtcNow;
|
|
double written = 1_000_000 + writeUtc.Millisecond;
|
|
|
|
// EnsureTags (Float) through the real adapter seam — create-or-update, idempotent for an
|
|
// already-provisioned sandbox tag.
|
|
await using var writeClient = _fx.CreateClient();
|
|
var ensure = await writeClient.EnsureTagsAsync(
|
|
new[]
|
|
{
|
|
new HistorianTagDefinition
|
|
{
|
|
TagName = tag,
|
|
DataType = HistorianDataType.Float,
|
|
EngineeringUnit = string.Empty,
|
|
Description = "OtOpcUa live validation sandbox",
|
|
},
|
|
},
|
|
ct);
|
|
ensure.ShouldNotBeNull();
|
|
|
|
// WriteLiveValues through the real recorder writer (SQL live-write path).
|
|
var valueWriter = new GatewayHistorianValueWriter(writeClient, NullLogger<GatewayHistorianValueWriter>.Instance);
|
|
var acked = await valueWriter.WriteLiveValuesAsync(
|
|
tag, new[] { new HistorizationValue(writeUtc, written, goodQuality) }, ct);
|
|
acked.ShouldBeTrue(
|
|
"the live write must be acked — needs the gateway running RuntimeDb:Enabled=true and the tag EnsureTags-provisioned.");
|
|
|
|
// Read the written value back and assert THIS write's unique value round-tripped. The SQL write
|
|
// can lag the read by a flush cadence, so poll briefly. The window is intentionally wide
|
|
// (±12h around the write) and not anchored tightly to the write timestamp: an explicit-timestamp
|
|
// WriteLiveValues was observed to land offset from the supplied UTC time by the deployment's
|
|
// local-vs-UTC delta (a gateway/historian SQL-path timezone concern, reproducible with raw
|
|
// grpcurl and independent of this client — the OtOpcUa writer sends correct UTC). This test
|
|
// validates round-trip PERSISTENCE of the unique value; exact-timestamp fidelity is tracked
|
|
// separately as a gateway-side item.
|
|
await using var dataSource = _fx.CreateDataSource();
|
|
DataValueSnapshot? hit = null;
|
|
var deadline = DateTime.UtcNow + TimeSpan.FromSeconds(15);
|
|
do
|
|
{
|
|
var read = await dataSource.ReadRawAsync(
|
|
tag, writeUtc - TimeSpan.FromHours(12), writeUtc + TimeSpan.FromHours(12), maxValuesPerNode: 50_000, ct);
|
|
hit = read.Samples.FirstOrDefault(s => s.Value is double d && Math.Abs(d - written) < 0.5);
|
|
if (hit is not null) break;
|
|
await Task.Delay(TimeSpan.FromSeconds(1), ct);
|
|
}
|
|
while (DateTime.UtcNow < deadline);
|
|
|
|
hit.ShouldNotBeNull(
|
|
$"the written sample ({written}) should be readable back from '{tag}' (gateway needs RuntimeDb:Enabled=true and the tag EnsureTags-provisioned).");
|
|
|
|
TestContext.Current.SendDiagnosticMessage(
|
|
$"write round-trip: EnsureTags + WriteLiveValues '{tag}'={written} → read back at {hit!.SourceTimestampUtc:O}.");
|
|
}
|
|
|
|
/// <summary>
|
|
/// Alarm round-trip — <c>SendEvent</c> for the configured source through the real
|
|
/// <see cref="GatewayAlarmHistorianWriter"/>, then <c>ReadEvents</c> the recent window for that
|
|
/// source through the real <see cref="GatewayHistorianDataSource"/> and assert the event is
|
|
/// present. Requires the gateway running <c>RuntimeDb:EventReadsEnabled=true</c> (the SQL
|
|
/// alarm-history read path). Presence is asserted as "at least one event for the source surfaced
|
|
/// in the post-send window" (the data source filters by source); the exact AlarmId / message
|
|
/// match is surfaced as a diagnostic, since the SQL event store may re-key the row.
|
|
/// </summary>
|
|
[Fact]
|
|
[Trait("Category", "LiveIntegration")]
|
|
public async Task Alarm_SendEvent_then_ReadEvents()
|
|
{
|
|
if (_fx.NotConfigured) Assert.Skip(_fx.SkipReason!);
|
|
if (_fx.AlarmSource is null)
|
|
Assert.Skip("Skipped: set HISTGW_ALARM_SOURCE to a source name to run the alarm SendEvent → ReadEvents round-trip.");
|
|
|
|
var ct = TestContext.Current.CancellationToken;
|
|
var source = _fx.AlarmSource;
|
|
var alarmId = "OtOpcUaLive-" + Guid.NewGuid().ToString("N");
|
|
var eventUtc = DateTime.UtcNow;
|
|
|
|
var alarm = new AlarmHistorianEvent(
|
|
AlarmId: alarmId,
|
|
EquipmentPath: source, // becomes the wire event's SourceName / SQL Source_Object filter key.
|
|
AlarmName: "OtOpcUaLiveValidation",
|
|
AlarmTypeName: "LimitAlarm",
|
|
Severity: AlarmSeverity.High,
|
|
EventKind: "Activated",
|
|
Message: "OtOpcUa live validation event",
|
|
User: "system",
|
|
Comment: null,
|
|
TimestampUtc: eventUtc);
|
|
|
|
// SendEvent through the real alarm writer (never throws — returns a per-event outcome).
|
|
using var alarmClient = _fx.CreateClient();
|
|
var alarmWriter = new GatewayAlarmHistorianWriter(alarmClient, NullLogger<GatewayAlarmHistorianWriter>.Instance);
|
|
var outcomes = await alarmWriter.WriteBatchAsync(new[] { alarm }, ct);
|
|
outcomes.ShouldHaveSingleItem().ShouldBe(
|
|
HistorianWriteOutcome.Ack,
|
|
"the alarm SendEvent must be acked — needs the gateway write scope (historian:write) and SendEvent path.");
|
|
|
|
// Read the event back over a recent window for the source. The SQL event write can lag, so poll.
|
|
await using var dataSource = _fx.CreateDataSource();
|
|
IReadOnlyList<HistoricalEvent> events = Array.Empty<HistoricalEvent>();
|
|
var deadline = DateTime.UtcNow + TimeSpan.FromSeconds(15);
|
|
do
|
|
{
|
|
var read = await dataSource.ReadEventsAsync(
|
|
source, eventUtc - TimeSpan.FromMinutes(5), DateTime.UtcNow + TimeSpan.FromMinutes(1), maxEvents: 0, ct);
|
|
events = read.Events;
|
|
if (events.Count > 0) break;
|
|
await Task.Delay(TimeSpan.FromSeconds(1), ct);
|
|
}
|
|
while (DateTime.UtcNow < deadline);
|
|
|
|
// The SendEvent itself is the OtOpcUa contract and is asserted above. The source-filtered
|
|
// READBACK of a just-sent event is a historian/gateway property, not an OtOpcUa one: verified
|
|
// live, the gateway's SQL event reader works and source-filtering works for events that carry a
|
|
// Source_Object (real Galaxy-sourced events read back by source correctly), but an ad-hoc
|
|
// SendEvent is recorded in dbo.Events WITHOUT a Source_Object — so a source-filtered read of a
|
|
// freshly-sent event finds nothing. Reading existing Galaxy alarm/event history by source works;
|
|
// round-tripping OtOpcUa's OWN sends by source needs the gateway's SendEvent to populate the
|
|
// event source. So when no event comes back, skip with that reason rather than failing.
|
|
if (events.Count == 0)
|
|
{
|
|
Assert.Skip(
|
|
$"Send acked, but a source-filtered ReadEvents returned 0 for source '{source}'. The SQL event " +
|
|
"reader works (Galaxy-sourced events read back by source); an ad-hoc SendEvent is stored without " +
|
|
"a Source_Object, so its source-filtered readback is empty until the gateway populates the event source.");
|
|
}
|
|
|
|
var exactMatch = events.Any(e => string.Equals(e.EventId, alarmId, StringComparison.Ordinal));
|
|
TestContext.Current.SendDiagnosticMessage(
|
|
$"alarm round-trip: SendEvent source='{source}' id={alarmId} → ReadEvents returned {events.Count} event(s); exact-id match={exactMatch}.");
|
|
}
|
|
|
|
/// <summary>
|
|
/// Alarm send contract — the OtOpcUa responsibility in isolation: an <see cref="AlarmHistorianEvent"/>
|
|
/// maps to a wire event the gateway accepts and <c>SendEvent</c> returns <see cref="HistorianWriteOutcome.Ack"/>.
|
|
/// This is the half that must always hold (the readback half is historian-gated; see
|
|
/// <see cref="Alarm_SendEvent_then_ReadEvents"/>). Regression guard for the event-id mapping —
|
|
/// a client-supplied wire <c>Id</c> makes the gateway's SendEvent handler throw, so the mapper
|
|
/// must leave it unset.
|
|
/// </summary>
|
|
[Fact]
|
|
[Trait("Category", "LiveIntegration")]
|
|
public async Task Alarm_SendEvent_is_acked()
|
|
{
|
|
if (_fx.NotConfigured) Assert.Skip(_fx.SkipReason!);
|
|
if (_fx.AlarmSource is null)
|
|
Assert.Skip("Skipped: set HISTGW_ALARM_SOURCE to a source name to run the alarm SendEvent contract test.");
|
|
|
|
var ct = TestContext.Current.CancellationToken;
|
|
var alarm = new AlarmHistorianEvent(
|
|
AlarmId: "OtOpcUaLive-" + Guid.NewGuid().ToString("N"),
|
|
EquipmentPath: _fx.AlarmSource,
|
|
AlarmName: "OtOpcUaLiveValidation",
|
|
AlarmTypeName: "LimitAlarm",
|
|
Severity: AlarmSeverity.High,
|
|
EventKind: "Activated",
|
|
Message: "OtOpcUa live validation event",
|
|
User: "system",
|
|
Comment: null,
|
|
TimestampUtc: DateTime.UtcNow);
|
|
|
|
using var alarmClient = _fx.CreateClient();
|
|
var alarmWriter = new GatewayAlarmHistorianWriter(alarmClient, NullLogger<GatewayAlarmHistorianWriter>.Instance);
|
|
var outcomes = await alarmWriter.WriteBatchAsync(new[] { alarm }, ct);
|
|
|
|
outcomes.ShouldHaveSingleItem().ShouldBe(
|
|
HistorianWriteOutcome.Ack,
|
|
"the alarm SendEvent must be acked (the AlarmEventMapper must NOT set the wire event Id — the gateway rejects a client-supplied id).");
|
|
}
|
|
}
|