Joseph Doherty 21cac4c8c4 PR 4.W — Galaxy:Backend wiring + server-side factory registration
- GalaxyDriver.InitializeAsync now builds the production gw runtime (MxGatewayClient,
  GalaxyMxSession, GatewayGalaxySubscriber, GatewayGalaxyDataWriter,
  ReconnectSupervisor, HostConnectivityForwarder, PerPlatformProbeWatcher) when no
  test seams are pre-injected; Dispose tears the chain down in order.
- GetHealth surfaces supervisor.IsDegraded as DriverState.Degraded so a transport
  drop is observable without polling the supervisor directly.
- DiscoverAsync now refreshes the per-platform probe watcher's membership against
  $WinPlatform / $AppEngine objects after every discovery pass.
- OnPumpDataChange routes ScanState changes through the probe watcher in addition
  to fanning out OnDataChange to ISubscribable consumers.
- Server registers GalaxyDriver under "GalaxyMxGateway" alongside the legacy
  "Galaxy" GalaxyProxyDriver factory so DriverInstance rows can opt in.
- Bumped Server.Tests' Microsoft.Extensions.Logging.Abstractions to 10.0.7 to
  resolve the downgrade pulled in transitively via MxGateway.Client.
- Lifecycle factory tests switched to the internal seam-injection ctor so they
  no longer attempt a real gRPC connect during InitializeAsync.