aafb9d4929
Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now builds its RawPath -> definition table from the artifact's RawTagEntry set via a pure mapper. - Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory; TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath, no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited so a RawTagEntry round-trips the full authored def. Inspect() unchanged. - Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>). - Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build the table from RawTags at Initialize threading entry.WriteIdempotent onto each def; Discover/Teardown updated. - Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind RawTags from driver-config JSON. - CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig. - Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests -> FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam. - Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects). Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green. Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against the new API; expected).
77 lines
3.3 KiB
C#
77 lines
3.3 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
|
|
|
/// <summary>
|
|
/// CONV-4 (Modbus leg) — Modbus keys per-host resilience per SLAVE UNIT
|
|
/// (<c>host:port/unitN</c>). An authored raw tag carries its own <c>unitId</c> in its TagConfig so
|
|
/// multi-unit tags key their own breaker; <see cref="ModbusDriver.ResolveHost"/> resolves a RawPath
|
|
/// through the driver's authored RawPath → definition table. Under v3 the reference is always a
|
|
/// RawPath — an unauthored RawPath falls back to the driver-level host.
|
|
/// </summary>
|
|
[Trait("Category", "Unit")]
|
|
public sealed class ModbusUnitIdResolveHostTests
|
|
{
|
|
private sealed class NoopTransport : IModbusTransport
|
|
{
|
|
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
|
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
|
=> Task.FromResult(new byte[] { 0x03, 0x00 });
|
|
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
|
}
|
|
|
|
private static async Task<ModbusDriver> NewDriverAsync(params RawTagEntry[] rawTags)
|
|
{
|
|
var drv = new ModbusDriver(
|
|
new ModbusDriverOptions
|
|
{
|
|
Host = "10.0.0.1", Port = 502, UnitId = 1, RawTags = rawTags,
|
|
Probe = new ModbusProbeOptions { Enabled = false },
|
|
},
|
|
"modbus-1", _ => new NoopTransport());
|
|
await drv.InitializeAsync("{}", CancellationToken.None);
|
|
return drv;
|
|
}
|
|
|
|
/// <summary>The mapper reads an optional unitId into the definition.</summary>
|
|
[Fact]
|
|
public void FromTagConfig_reads_optional_unitId()
|
|
{
|
|
var json = """{"region":"HoldingRegisters","address":0,"dataType":"Int16","unitId":7}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, "cell/modbus/dev1/U7", out var def).ShouldBeTrue();
|
|
def.Name.ShouldBe("cell/modbus/dev1/U7");
|
|
def.UnitId.ShouldBe((byte)7);
|
|
}
|
|
|
|
/// <summary>An absent unitId leaves the definition on the driver-level default (null override).</summary>
|
|
[Fact]
|
|
public void FromTagConfig_absent_unitId_is_null()
|
|
{
|
|
var json = """{"region":"HoldingRegisters","address":0,"dataType":"Int16"}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, "cell/modbus/dev1/U0", out var def).ShouldBeTrue();
|
|
def.UnitId.ShouldBeNull();
|
|
}
|
|
|
|
/// <summary>An authored RawPath carrying a unitId keys its own per-unit host name.</summary>
|
|
[Fact]
|
|
public async Task RawPath_WithUnitId_ResolvesPerUnitHostName()
|
|
{
|
|
const string rawPath = "cell/modbus/dev1/U7";
|
|
var json = """{"region":"HoldingRegisters","address":0,"dataType":"Int16","unitId":7}""";
|
|
var drv = await NewDriverAsync(new RawTagEntry(rawPath, json, false));
|
|
drv.ResolveHost(rawPath).ShouldBe("10.0.0.1:502/unit7");
|
|
}
|
|
|
|
/// <summary>An authored RawPath without a unitId keys the driver-level unit host name.</summary>
|
|
[Fact]
|
|
public async Task RawPath_WithoutUnitId_KeysDriverDefaultUnit()
|
|
{
|
|
const string rawPath = "cell/modbus/dev1/U0";
|
|
var json = """{"region":"HoldingRegisters","address":0,"dataType":"Int16"}""";
|
|
var drv = await NewDriverAsync(new RawTagEntry(rawPath, json, false));
|
|
drv.ResolveHost(rawPath).ShouldBe("10.0.0.1:502/unit1");
|
|
}
|
|
}
|