using System.Diagnostics.Tracing;
using System.Reflection;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
/// <summary>
/// #729 — the probe worker delegate must not obtain its <see cref="CancellationToken"/> after it is
/// already running. The scheduling token passed to <c>Task.Run</c> only suppresses a task that is still
/// QUEUED; once the pool has passed the task's cancellation/start check, lifecycle teardown can finish
/// underneath it (the bounded join gives up and the CTS is disposed). A delegate that then reads
/// <c>cts.Token</c> throws <see cref="ObjectDisposedException"/>; one that reads the <c>_probeCts</c>
/// field sees null or the next generation's token.
/// </summary>
/// <remarks>
/// The seam is TPL's own <c>TaskStarted</c> event: <c>TplEventSource</c> raises it synchronously on the
/// worker thread AFTER the start check and BEFORE the delegate is invoked, so holding the listener
/// callback parks the probe worker in exactly the window the issue describes — deterministically, no
/// timing stress. The target task is identified by the <c>TaskScheduled</c> event raised on the test's
/// own (AsyncLocal-armed) flow during <c>InitializeAsync</c>; more than one armed schedule fails closed.
/// Queued-task cancellation (shutdown before the pool reaches the start check) is not exercised here:
/// there is no deterministic seam ahead of the start check, and that path is the BCL's own behaviour
/// for the scheduling token, which the fix leaves unchanged.
/// </remarks>
[Trait("Category", "Unit")]
public sealed class ModbusBackgroundLoopTokenLifetimeTests
{
private static readonly TimeSpan Bound = TimeSpan.FromSeconds(15);
private sealed class CountingTransport : IModbusTransport
{
public int SendCount;
public int DisposeCount;
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
{
Interlocked.Increment(ref SendCount);
return Task.FromResult(new byte[] { pdu[0], 2, 0, 0 });
}
public ValueTask DisposeAsync()
{
Interlocked.Increment(ref DisposeCount);
return ValueTask.CompletedTask;
}
}
/// <summary>Parks the one task scheduled on the armed flow inside its TaskStarted callback.</summary>
private sealed class TaskStartGate : EventListener
{
private const string TplSourceName = "System.Threading.Tasks.TplEventSource";
private const EventKeywords TaskTransfer = (EventKeywords)0x1;
private const EventKeywords Tasks = (EventKeywords)0x2;
public static readonly AsyncLocal<bool> Armed = new();
private readonly ManualResetEventSlim _release = new(false);
private int _targetTaskId = -1;
private int _armedSchedules;
private volatile bool _closed;
public TaskCompletionSource Started { get; } = new(TaskCreationOptions.RunContinuationsAsynchronously);
public int ArmedSchedules => Volatile.Read(ref _armedSchedules);
public bool ReleaseTimedOut { get; private set; }
/// <summary>Stops correlating new schedules once the arming operation has returned.</summary>
public void Close() => _closed = true;
public void Release() => _release.Set();
protected override void OnEventSourceCreated(EventSource eventSource)
{
if (eventSource.Name == TplSourceName)
EnableEvents(eventSource, EventLevel.Informational, TaskTransfer | Tasks);
}
protected override void OnEventWritten(EventWrittenEventArgs e)
{
if (e.EventName == "TaskScheduled")
{
if (_closed || !Armed.Value) return;
Interlocked.Increment(ref _armedSchedules);
Interlocked.CompareExchange(ref _targetTaskId, TaskId(e), -1);
}
else if (e.EventName == "TaskStarted")
{
var target = Volatile.Read(ref _targetTaskId);
if (target == -1 || TaskId(e) != target) return;
Started.TrySetResult();
// Bounded: a test that never releases must not wedge a pool thread forever.
if (!_release.Wait(Bound)) ReleaseTimedOut = true;
}
}
private static int TaskId(EventWrittenEventArgs e)
{
var i = e.PayloadNames!.IndexOf("TaskID");
return i < 0 ? -2 : Convert.ToInt32(e.Payload![i]);
}
public override void Dispose()
{
_release.Set();
base.Dispose();
}
}
private static ModbusDriverOptions ProbeOnlyOptions() => new()
{
Host = "fake",
Probe = new ModbusProbeOptions
{
Enabled = true,
Interval = TimeSpan.FromMilliseconds(50),
Timeout = TimeSpan.FromSeconds(1),
},
AutoProhibitReprobeInterval = null,
RawTags = ModbusRawTags.Entries([new ModbusTagDefinition("A", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16)]),
};
private static T? Field<T>(ModbusDriver drv, string name) where T : class =>
(T?)typeof(ModbusDriver).GetField(name, BindingFlags.NonPublic | BindingFlags.Instance)!.GetValue(drv);
/// <summary>Initializes on an armed flow and returns the parked background-loop task.</summary>
private static async Task<Task> InitializeAndParkProbeAsync(ModbusDriver drv, TaskStartGate gate, string taskField = "_probeTask")
{
TaskStartGate.Armed.Value = true;
try { await drv.InitializeAsync("{}", CancellationToken.None); }
finally
{
gate.Close();
TaskStartGate.Armed.Value = false;
}
gate.ArmedSchedules.ShouldBe(1, "exactly one task (the background loop) must be scheduled by initialize; anything else is ambiguous");
var probeTask = Field<Task>(drv, taskField);
Assert.NotNull(probeTask); // not Shouldly: its Task overload would be an un-awaited async assertion
await gate.Started.Task.WaitAsync(Bound, TestContext.Current.CancellationToken);
probeTask.IsCompleted.ShouldBeFalse("the worker must be parked after its start check, before its delegate runs");
return probeTask;
}
private static async Task SettleAsync(Task task)
{
try { await task.WaitAsync(Bound, TestContext.Current.CancellationToken); }
catch (TimeoutException) { throw; }
catch { /* outcome asserted by the caller from task.Status */ }
}
/// <summary>
/// A probe worker already past its start check when ShutdownAsync tears the driver down must still
/// complete cleanly on its own cancelled token once it runs — not fault on a disposed CTS, and not
/// touch the disposed transport.
/// </summary>
[Fact]
public async Task Started_probe_worker_released_after_shutdown_exits_cleanly_on_its_own_cancelled_token()
{
var fake = new CountingTransport();
var drv = new ModbusDriver(ProbeOnlyOptions(), "modbus-729", _ => fake);
using var gate = new TaskStartGate();
try
{
var probeTask = await InitializeAndParkProbeAsync(drv, gate);
// Teardown runs to completion while the worker is parked: the bounded join times out and the
// CTS is disposed and the field cleared before the delegate has read anything.
await drv.ShutdownAsync(CancellationToken.None);
Field<CancellationTokenSource>(drv, "_probeCts").ShouldBeNull();
fake.DisposeCount.ShouldBe(1);
probeTask.IsCompleted.ShouldBeFalse();
gate.Release();
await SettleAsync(probeTask);
gate.ReleaseTimedOut.ShouldBeFalse();
probeTask.Exception?.Flatten().InnerException.ShouldBeNull(
"the late worker must not fault obtaining its token after teardown disposed the CTS");
probeTask.Status.ShouldBe(TaskStatus.RanToCompletion);
Volatile.Read(ref fake.SendCount).ShouldBe(0, "a worker released after teardown must not probe the disposed transport");
}
finally
{
gate.Release();
await drv.DisposeAsync();
}
}
/// <summary>
/// A probe worker of generation N released after a replacement initialize must run on generation
/// N's (cancelled) token — not adopt generation N+1's live token and keep probing the N transport —
/// while generation N+1's own probe loop stays live.
/// </summary>
[Fact]
public async Task Started_probe_worker_released_after_replacement_keeps_its_own_generation_token()
{
var transports = new List<CountingTransport>();
var drv = new ModbusDriver(ProbeOnlyOptions(), "modbus-729", _ =>
{
var t = new CountingTransport();
lock (transports) transports.Add(t);
return t;
});
using var gate = new TaskStartGate();
try
{
var firstProbe = await InitializeAndParkProbeAsync(drv, gate);
var first = transports[0];
await drv.ReinitializeAsync("{}", CancellationToken.None);
transports.Count.ShouldBe(2);
var second = transports[1];
first.DisposeCount.ShouldBe(1);
var liveCts = Field<CancellationTokenSource>(drv, "_probeCts");
liveCts.ShouldNotBeNull();
firstProbe.IsCompleted.ShouldBeFalse();
gate.Release();
await SettleAsync(firstProbe);
gate.ReleaseTimedOut.ShouldBeFalse();
firstProbe.Exception?.Flatten().InnerException.ShouldBeNull();
firstProbe.Status.ShouldBe(TaskStatus.RanToCompletion,
"the generation-1 worker must exit on its own cancelled token");
Volatile.Read(ref first.SendCount).ShouldBe(0, "the generation-1 worker must not probe its disposed transport");
// Generation 2 is unaffected: its loop is live and its CTS is still the published, uncancelled one.
var deadline = DateTime.UtcNow + Bound;
while (Volatile.Read(ref second.SendCount) == 0 && DateTime.UtcNow < deadline)
await Task.Delay(10, TestContext.Current.CancellationToken);
Volatile.Read(ref second.SendCount).ShouldBeGreaterThan(0);
Field<CancellationTokenSource>(drv, "_probeCts").ShouldBeSameAs(liveCts);
liveCts!.IsCancellationRequested.ShouldBeFalse();
}
finally
{
gate.Release();
await drv.DisposeAsync();
}
}
/// <summary>The re-probe loop gets the same guarantee as the probe loop.</summary>
[Fact]
public async Task Started_reprobe_worker_released_after_shutdown_exits_cleanly_on_its_own_cancelled_token()
{
var fake = new CountingTransport();
var opts = new ModbusDriverOptions
{
Host = "fake",
Probe = new ModbusProbeOptions { Enabled = false },
AutoProhibitReprobeInterval = TimeSpan.FromMilliseconds(50),
RawTags = ModbusRawTags.Entries([new ModbusTagDefinition("A", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16)]),
};
var drv = new ModbusDriver(opts, "modbus-729", _ => fake);
using var gate = new TaskStartGate();
try
{
var reprobeTask = await InitializeAndParkProbeAsync(drv, gate, "_reprobeTask");
await drv.ShutdownAsync(CancellationToken.None);
Field<CancellationTokenSource>(drv, "_reprobeCts").ShouldBeNull();
reprobeTask.IsCompleted.ShouldBeFalse();
gate.Release();
await SettleAsync(reprobeTask);
gate.ReleaseTimedOut.ShouldBeFalse();
reprobeTask.Exception?.Flatten().InnerException.ShouldBeNull(
"the late re-probe worker must not fault obtaining its token after teardown disposed the CTS");
reprobeTask.Status.ShouldBe(TaskStatus.RanToCompletion);
}
finally
{
gate.Release();
await drv.DisposeAsync();
}
}
}