namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
/// <summary>
/// Per-family libplctag defaults for PCCC PLCs. SLC 500 / MicroLogix / PLC-5 / LogixPccc
/// (Logix controller accessed via the PLC-5 compatibility layer — rare but real).
/// </summary>
public sealed record AbLegacyPlcFamilyProfile(
string LibplctagPlcAttribute,
string DefaultCipPath,
/// <summary>
/// Reserved for future array-length clamping. <b>Not currently enforced anywhere in the
/// driver.</b> The values are approximate upper bounds derived from PCCC packet payload
/// limits (e.g. SLC 5/05 240 bytes is the PCCC-over-EIP data cap, not a libplctag fragment
/// limit). Do not rely on this field for sizing decisions until an enforcement point is added.
/// </summary>
int MaxTagBytes,
bool SupportsStringFile,
bool SupportsLongFile,
/// <summary>
/// PLC-5 only: the word and bit indices on <c>I:</c>/<c>O:</c> references are octal
/// (<c>I:017/07</c>), as RSLogix 5 displays them. SLC / MicroLogix / Logix-PCCC stay decimal.
/// </summary>
bool OctalIoAddressing = false,
/// <summary>MicroLogix only: RTC / HSC / DLS / MMI / PTO / PWM / STI / EII / IOS / BHI function files.</summary>
bool SupportsFunctionFiles = false)
{
/// <summary>Gets the profile for the specified PLC family.</summary>
/// <param name="family">The PLC family.</param>
/// <remarks>
/// Any unrecognised <paramref name="family"/> value (e.g. an integer cast to the enum, or a
/// value added to <see cref="AbLegacyPlcFamily"/> before this switch is updated) silently
/// returns the <see cref="Slc500"/> profile. This is intentional: it preserves
/// forward-compatibility for device configs authored against a build that predates a new
/// family enum member, preferring a safe default over a startup exception.
/// </remarks>
/// <returns>The libplctag profile defaults for <paramref name="family"/>.</returns>
public static AbLegacyPlcFamilyProfile ForFamily(AbLegacyPlcFamily family) => family switch
{
AbLegacyPlcFamily.Slc500 => Slc500,
AbLegacyPlcFamily.MicroLogix => MicroLogix,
AbLegacyPlcFamily.Plc5 => Plc5,
AbLegacyPlcFamily.LogixPccc => LogixPccc,
_ => Slc500,
};
public static readonly AbLegacyPlcFamilyProfile Slc500 = new(
LibplctagPlcAttribute: "slc500",
DefaultCipPath: "1,0",
MaxTagBytes: 240, // SLC 5/05 PCCC max packet data
SupportsStringFile: true, // ST file available SLC 5/04+
SupportsLongFile: true); // L file available SLC 5/05+ (decimal I:/O: indices, RSLogix 500)
public static readonly AbLegacyPlcFamilyProfile MicroLogix = new(
LibplctagPlcAttribute: "micrologix",
DefaultCipPath: "", // MicroLogix 1100/1400 use direct EIP, no backplane path
MaxTagBytes: 232,
SupportsStringFile: true,
SupportsLongFile: false, // ML 1100/1200/1400 don't ship L files
SupportsFunctionFiles: true); // ML 1100/1400 expose RTC/HSC/DLS/MMI/PTO/PWM/STI/EII/IOS/BHI
public static readonly AbLegacyPlcFamilyProfile Plc5 = new(
LibplctagPlcAttribute: "plc5",
DefaultCipPath: "1,0",
MaxTagBytes: 240, // DF1 full-duplex packet limit at 264 bytes, PCCC-over-EIP caps lower
SupportsStringFile: true,
SupportsLongFile: false, // PLC-5 predates L files
OctalIoAddressing: true); // RSLogix 5 displays I:/O: word + bit indices as octal (#244)
/// <summary>
/// Logix ControlLogix / CompactLogix accessed through the legacy PCCC compatibility layer.
/// Rare but real — some legacy HMI integrations address Logix controllers as if they were
/// PLC-5 via the PCCC-passthrough mechanism.
/// </summary>
public static readonly AbLegacyPlcFamilyProfile LogixPccc = new(
LibplctagPlcAttribute: "logixpccc",
DefaultCipPath: "1,0",
MaxTagBytes: 240,
SupportsStringFile: true,
SupportsLongFile: true);
}
/// <summary>Which PCCC PLC family the device is.</summary>
public enum AbLegacyPlcFamily
{
Slc500,
MicroLogix,
Plc5,
LogixPccc,
}