lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/Docker
Joseph Doherty b13bdc154a test(ablegacy): deploy the PCCC fixture, one port per family (#534)
The AbLegacy integration suite has never run against a simulator.
/opt/otopcua-ablegacy/ did not exist on the Docker host — the stack was written
but never deployed — and every ab_server across BOTH ab fixtures bound :44818.
So the AB CIP fixture's ControlLogix container (up for two weeks) answered this
suite's TCP reachability probe, the suite declined to skip, and it ran SLC500-mode
PCCC against a ControlLogix. Four failures that read as "fixture missing".

Two structural problems, both fixed here:

- The theory parameterises over all three PCCC families, but only one container
  could ever exist on the shared port, so at least two cases failed on every
  conceivable run. The suite was un-greenable by construction, and
  AB_LEGACY_COMPOSE_PROFILE existed to paper over it by filtering the theory
  down to whichever container happened to be up.
- A reachability probe that cannot tell one simulator from another is not a skip
  gate. It answered "is some ab_server listening", which is a different question
  from the one the caller is asking, and reported the difference as a test
  failure.

Each family now has its own host port — 44819 slc500, 44820 micrologix, 44821
plc5 — so all three run together and alongside AbCip on 44818 (ab_server still
listens on 44818 inside each container; only the host mapping differs). Skip is
per-family via SkipReasonFor(profile); the class-level gate runs if ANY family is
up so one down container cannot silently skip the other two.
AB_LEGACY_COMPOSE_PROFILE now applies only in AB_LEGACY_ENDPOINT-pinned
real-hardware mode, where the family genuinely is a property of the one device.
This finally makes true what the fixture's XML doc has claimed from the start —
that it and the AB CIP fixture can point at different containers simultaneously.

Deployed to /opt/otopcua-ablegacy/ on 10.100.0.35; all three containers running.

The 4 tests still FAIL, and are left red on purpose — see #534. Now aimed at
correct-family simulators, the PCCC exchange itself returns BadCommunicationError
for every server-path / client-cip-path permutation, reproduced outside the test
harness via the driver CLI. That is a true signal about the driver (or about
libplctag's PCCC support against ab_server) that skipping would hide. What
changed here is that the failure is now diagnostic instead of an artifact of a
port collision.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-08-01 02:18:53 -04:00
..

AB Legacy PCCC integration-test fixture — ab_server (Docker)

libplctag's ab_server supports both CIP (ControlLogix / CompactLogix / Micro800) and PCCC (SLC 500 / MicroLogix / PLC-5) families from one binary. This fixture reuses the AB CIP Docker image (otopcua-ab-server:libplctag-release) with different --plc flags. No new Dockerfile needed — the compose file's build: block points at the AB CIP Docker/ folder so docker compose build from here reuses the same multi-stage build.

Docker is the only supported launch path; a fresh clone needs Docker Desktop and nothing else.

File Purpose
docker-compose.yml Three per-family services — slc500 on :44819, micrologix on :44820, plc5 on :44821. Run them together; they no longer collide with each other or with the AB CIP fixture on :44818.

Run

From the repo root:

# SLC 500 family — widest PCCC coverage
docker compose -f tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests\Docker\docker-compose.yml --profile slc500 up

# Per-family
docker compose -f tests\...\Docker\docker-compose.yml --profile micrologix up
docker compose -f tests\...\Docker\docker-compose.yml --profile plc5 up

Detached + stop:

docker compose -f tests\...\Docker\docker-compose.yml --profile slc500 up -d
docker compose -f tests\...\Docker\docker-compose.yml --profile slc500 down

First run builds the otopcua-ab-server:libplctag-release image (~3-5 min — clones libplctag + compiles ab_server). If the AB CIP fixture already built the image locally, docker reuses the cached layers + this runs in seconds. (Until 2026-08-01 every family bound :44818, so only one could run and the theory's other two cases always failed; each now has its own port.) To switch families stop the current service + start another.

Endpoint

  • Default: 10.100.0.35:44819 / :44820 / :44821 per family (the shared Docker host)
  • Override with AB_LEGACY_ENDPOINT=host:port to point at a real SLC / MicroLogix / PLC-5 PLC on its native port.

Env vars

Var Default Purpose
AB_LEGACY_ENDPOINT unset — per-family ports on 10.100.0.35 host:port of a single PCCC device, pinning every family to it (real-hardware mode).
AB_LEGACY_CIP_PATH 1,0 CIP routing path portion of the ab://host:port/<path> URI. ab_server rejects empty paths at the CIP unconnected-send layer; real SLC/MicroLogix/PLC-5 hardware accepts empty (no backplane). Set to empty (AB_LEGACY_CIP_PATH=) when pointing at real hardware.
AB_LEGACY_COMPOSE_PROFILE unset Only consulted when AB_LEGACY_ENDPOINT pins an endpoint: names which family that one device is, so the SLC500-only write test skips against other hardware. Against the Docker fixture it is unnecessary — each family has its own port, and each test skips itself if its own port is down.

Run the integration tests

In a separate shell with a container up, tell the suite which profile is running so only the matching theory-parameterization executes:

cd C:\Users\dohertj2\Desktop\lmxopcua
$env:AB_LEGACY_COMPOSE_PROFILE = "slc500"   # or "micrologix" / "plc5"
dotnet test tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests

Against real SLC / MicroLogix / PLC-5 hardware, set the endpoint + an empty cip-path + leave the profile unset so all 3 parameterizations run (real PLCs answer any valid family):

$env:AB_LEGACY_ENDPOINT = "10.0.1.50:44818"
$env:AB_LEGACY_CIP_PATH = ""     # empty — real hardware has no backplane
dotnet test tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests

AbLegacyServerFixture TCP-probes the endpoint at collection init and sets a skip reason when the listener isn't reachable. Tests use [AbLegacyFact] / [AbLegacyTheory] which check the same gate.

What each family seeds

PCCC tag format is <file>[<size>] without a type suffix — file letter implies type:

  • N = 16-bit signed integer
  • F = 32-bit IEEE 754 float
  • B = 1-bit boolean (stored as uint16, bit-addressable via /n)
  • L = 32-bit signed integer (SLC 5/05 V15+ only)
  • ST = 82-byte ASCII string (MicroLogix-specific extension)
Family Seeded tags Notes
SLC 500 N7[10], F8[10], B3[10], L19[10] Baseline; covers the four numeric file types a typical SLC project uses
MicroLogix B3[10], N7[10], L19[10] No F8 — MicroLogix 1000 has no float file; use L19 when scaled integers aren't enough
PLC-5 N7[10], F8[10], B3[10] No L — PLC-5 predates the L file type; DINT equivalents went in integer files

Known limitations

ab_server rejects empty CIP paths

libplctag's ab_server enforces a non-empty CIP routing path at the unconnected-send layer before forwarding to the PCCC dispatcher; a client-side ab://host:port/ with nothing after the / surfaces as BadCommunicationError (0x80050000) with no server-side log line.

Real SLC/PLC-5 hardware has no backplane routing, so an empty path is how field devices are addressed. The fixture defaults to /1,0 (port-1/slot-0 — the conventional ControlLogix backplane path) which the ab_server accepts; operators targeting real hardware set AB_LEGACY_CIP_PATH= (empty) to exercise authentic wire semantics.

Previous versions of this README described PCCC as "upstream-broken" — the root cause turned out to be the cip-path gate above, not a gap in pccc.c. N-file (Int16), F-file (Float32), and L-file (Int32) round- trip cleanly across SLC500, MicroLogix, and PLC-5 modes.

Bit-file writes on ab_server

B3:0/5-style bit-in-boolean writes currently surface 0x803D0000 against ab_server --plc=SLC500; bit reads work. Non-blocking for the smoke suite (which targets N-file Int16 + F-file float reads), but bit-write fidelity isn't simulator-verified — route operator-critical bit writes to real hardware or RSEmulate 500 until upstream resolves.

Other known gaps (unchanged from ab_server)

  • Timer / Counter file decomposition — PCCC T4 / C5 files contain three-field structs (.ACC / .PRE / .DN). Not in ab_server's scope; tests targeting T4:0.ACC stay unit-only.
  • ST (ASCII string) files — real MicroLogix ST files have a length field plus CRLF-sensitive semantics that don't round-trip cleanly.
  • Indirect addressing (N7:[N10:5]) — not in ab_server's scope.
  • DF1 serial wire behaviour — the whole ab_server path is TCP; DF1 radio / serial fidelity needs real hardware.

See docs/drivers/AbLegacy-Test-Fixture.md for the full coverage map.