Files
lmxopcua/tests
Joseph Doherty 1c1705fa77 fix(galaxy): #865 review round 3 - budget-safe stream wait, dead pump, fast-path drop
- StreamRequestWait 1 s (under Tier-A Read 2 s / Subscribe 5 s budgets) and
  a stale pump is only waited on while the supervisor is reopening or
  replaying (or a restart is underway); in a reconnect backoff the advise
  proceeds at once. The no-stream log is a rate-limited Warning while
  Healthy, Debug otherwise.
- A current-session pump whose loop has ended is not a stream: if the
  supervisor already reports Healthy (its fault was swallowed while it was
  recovering) the failure is re-reported to start a new cycle.
- Subscribe/Read no longer start the pump directly (only
  AwaitCurrentEventStreamAsync does, honouring the replay restart flag);
  the teardown refusal is an explicit ThrowIfRuntimeStopping.
- SubscriptionRegistry.ResolveOrPark fast path: the handle lookup and the
  open-window check were not atomic, so a subscribe that registered the
  handle and closed its window in between got its initial value dropped as
  stale (found by a stress run: the first event of a bulk advise lost). It
  re-looks-up before declaring stale. Deterministic test via a seam.
- Tests: first Read on a fresh driver, replay of a data subscription.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk