lmxopcua/scripts/e2e/test-focas.ps1
2026-04-26 04:32:43 -04:00

114 lines
4.1 KiB
PowerShell

#Requires -Version 7.0
<#
.SYNOPSIS
End-to-end CLI test for the FOCAS (Fanuc CNC) driver.
.DESCRIPTION
**Hardware-gated.** There is no public FOCAS simulator; the driver's
FwlibFocasClient P/Invokes Fanuc's licensed Fwlib32.dll. Against a dev
box without the DLL on PATH the test will skip with a clear message.
Against a real CNC with the DLL present it runs probe / driver-loopback /
server-bridge the same way the other scripts do.
Set FOCAS_TRUST_WIRE=1 when -CncHost points at a real CNC to un-gate.
.PARAMETER CncHost
IP or hostname of the CNC. Default 127.0.0.1 — override for real runs.
.PARAMETER CncPort
FOCAS TCP port. Default 8193.
.PARAMETER Address
FOCAS address to exercise. Default R100 (PMC R-file register).
.PARAMETER OpcUaUrl
OtOpcUa server endpoint.
.PARAMETER BridgeNodeId
NodeId at which the server publishes the Address.
.PARAMETER Write
Issue #268 / plan PR F4-a — opts the script into the post-F4-a write
stages. F4-a ships the write infrastructure (driver-level Writes.Enabled
flag + per-tag Writable opt-in) without any actual wire writes; F4-b/c
populate this stage with real macro / parameter / PMC write coverage.
Until then the switch is a no-op marker so the e2e harness records that
the write surface was deliberately exercised (or skipped).
#>
param(
[string]$CncHost = "127.0.0.1",
[int]$CncPort = 8193,
[string]$Address = "R100",
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
[Parameter(Mandatory)] [string]$BridgeNodeId,
[switch]$Write
)
$ErrorActionPreference = "Stop"
. "$PSScriptRoot/_common.ps1"
if (-not ($env:FOCAS_TRUST_WIRE -eq "1" -or $env:FOCAS_TRUST_WIRE -eq "true")) {
Write-Skip "FOCAS_TRUST_WIRE not set — no public simulator exists (task #222 tracks the lab rig). Set =1 when -CncHost points at a real CNC with Fwlib32.dll on PATH."
exit 0
}
$focasCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli" `
-ExeName "otopcua-focas-cli"
$opcUaCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
-ExeName "otopcua-cli"
$commonFocas = @("-h", $CncHost, "-p", $CncPort)
$results = @()
$results += Test-Probe `
-Cli $focasCli `
-ProbeArgs (@("probe") + $commonFocas + @("-a", $Address, "--type", "Int16"))
$writeValue = Get-Random -Minimum 1 -Maximum 9999
$results += Test-DriverLoopback `
-Cli $focasCli `
-WriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $writeValue)) `
-ReadArgs (@("read") + $commonFocas + @("-a", $Address, "-t", "Int16")) `
-ExpectedValue "$writeValue"
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
$results += Test-ServerBridge `
-DriverCli $focasCli `
-DriverWriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $bridgeValue)) `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-ExpectedValue "$bridgeValue"
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
$results += Test-OpcUaWriteBridge `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $focasCli `
-DriverReadArgs (@("read") + $commonFocas + @("-a", $Address, "-t", "Int16")) `
-ExpectedValue "$reverseValue"
$subValue = Get-Random -Minimum 30000 -Maximum 32766
$results += Test-SubscribeSeesChange `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $focasCli `
-DriverWriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $subValue)) `
-ExpectedValue "$subValue"
if ($Write) {
# F4-a no-op stage. Real per-kind write coverage lands in F4-b/c which extend the wire
# client past the BadNotSupported short-circuit + populate this branch with
# macro / parameter / PMC write assertions. Logged here so the harness records that the
# operator deliberately requested the write path.
Write-Host "[skip] -Write requested; F4-a ships infrastructure only — wire-write stages land in F4-b/c (issue #268)."
}
Write-Summary -Title "FOCAS e2e" -Results $results
if ($results | Where-Object { -not $_.Passed }) { exit 1 }