Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Tests.v1Archive/Integration/HistorizingFlagTests.cs
Joseph Doherty a3d16a28f1 Phase 2 Stream D Option B — archive v1 surface + new Driver.Galaxy.E2E parity suite. Non-destructive intermediate state: the v1 OtOpcUa.Host + Historian.Aveva + Tests + IntegrationTests projects all still build (494 v1 unit + 6 v1 integration tests still pass when run explicitly), but solution-level dotnet test ZB.MOM.WW.OtOpcUa.slnx now skips them via IsTestProject=false on the test projects + archive-status PropertyGroup comments on the src projects. The destructive deletion is reserved for Phase 2 PR 3 with explicit operator review per CLAUDE.md "only use destructive operations when truly the best approach". tests/ZB.MOM.WW.OtOpcUa.Tests/ renamed via git mv to tests/ZB.MOM.WW.OtOpcUa.Tests.v1Archive/; csproj <AssemblyName> kept as the original ZB.MOM.WW.OtOpcUa.Tests so v1 OtOpcUa.Host's [InternalsVisibleTo("ZB.MOM.WW.OtOpcUa.Tests")] still matches and the project rebuilds clean. tests/ZB.MOM.WW.OtOpcUa.IntegrationTests gets <IsTestProject>false</IsTestProject>. src/ZB.MOM.WW.OtOpcUa.Host + src/ZB.MOM.WW.OtOpcUa.Historian.Aveva get PropertyGroup archive-status comments documenting they're functionally superseded but kept in-build because cascading dependencies (Historian.Aveva → Host; IntegrationTests → Host) make a single-PR deletion high blast-radius. New tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/ project (.NET 10) with ParityFixture that spawns OtOpcUa.Driver.Galaxy.Host.exe (net48 x86) as a Process.Start subprocess with OTOPCUA_GALAXY_BACKEND=db env vars, awaits 2s for the PipeServer to bind, then exposes a connected GalaxyProxyDriver; skips on non-Windows / Administrator shells (PipeAcl denies admins per decision #76) / ZB unreachable / Host EXE not built — each skip carries a SkipReason string the test method reads via Assert.Skip(SkipReason). RecordingAddressSpaceBuilder captures every Folder/Variable/AddProperty registration so parity tests can assert on the same shape v1 LmxNodeManager produced. HierarchyParityTests (3) — Discover returns gobjects with attributes; attribute full references match the tag.attribute Galaxy reference grammar; HistoryExtension flag flows through correctly. StabilityFindingsRegressionTests (4) — one test per 2026-04-13 stability finding from commits c76ab8f and 7310925: phantom probe subscription doesn't corrupt unrelated host status; HostStatusChangedEventArgs structurally carries a specific HostName + OldState + NewState (event signature mathematically prevents the v1 cross-host quality-clear bug); all GalaxyProxyDriver capability methods return Task or Task<T> (sync-over-async would deadlock OPC UA stack thread); AcknowledgeAsync completes before returning (no fire-and-forget background work that could race shutdown). Solution test count: 470 pass / 7 skip (E2E on admin shell) / 1 pre-existing Phase 0 baseline. Run archived suites explicitly: dotnet test tests/ZB.MOM.WW.OtOpcUa.Tests.v1Archive (494 pass) + dotnet test tests/ZB.MOM.WW.OtOpcUa.IntegrationTests (6 pass). docs/v2/V1_ARCHIVE_STATUS.md inventories every archived surface with run-it-explicitly instructions + a 10-step deletion plan for PR 3 + rollback procedure (git revert restores all four projects). docs/v2/implementation/exit-gate-phase-2-final.md supersedes the two partial-exit docs with the per-stream status table (A/B/C/D/E all addressed, D split across PR 2/3 per safety protocol), the test count breakdown, fresh adversarial review of PR 2 deltas (4 new findings: medium IsTestProject=false safety net loss, medium structural-vs-behavioral stability tests, low backend=db default, low Process.Start env inheritance), the 8 carried-forward findings from exit-gate-phase-2.md, the recommended PR order (1 → 2 → 3 → 4). docs/v2/implementation/pr-2-body.md is the Gitea web-UI paste-in for opening PR 2 once pushed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 00:56:21 -04:00

101 lines
3.8 KiB
C#

using System.Collections.Generic;
using System.Threading.Tasks;
using Opc.Ua;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Host.Domain;
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
namespace ZB.MOM.WW.OtOpcUa.Tests.Integration
{
public class HistorizingFlagTests
{
private static FakeGalaxyRepository CreateRepo()
{
return new FakeGalaxyRepository
{
Hierarchy = new List<GalaxyObjectInfo>
{
new()
{
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false
}
},
Attributes = new List<GalaxyAttributeInfo>
{
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "HistorizedAttr",
FullTagReference = "TestObj.HistorizedAttr", MxDataType = 2, IsHistorized = true
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "NormalAttr",
FullTagReference = "TestObj.NormalAttr", MxDataType = 5, IsHistorized = false
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "AlarmAttr",
FullTagReference = "TestObj.AlarmAttr", MxDataType = 1, IsAlarm = true
}
}
};
}
/// <summary>
/// Verifies that historized Galaxy attributes advertise OPC UA historizing support and history-read access.
/// </summary>
[Fact]
public async Task HistorizedAttribute_HasHistorizingTrue_AndHistoryReadAccess()
{
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(repo: CreateRepo());
await fixture.InitializeAsync();
try
{
using var client = new OpcUaTestClient();
await client.ConnectAsync(fixture.EndpointUrl);
var nodeId = client.MakeNodeId("TestObj.HistorizedAttr");
var historizing = client.ReadAttribute(nodeId, Attributes.Historizing);
((bool)historizing.Value).ShouldBeTrue();
var accessLevel = client.ReadAttribute(nodeId, Attributes.AccessLevel);
var level = (byte)accessLevel.Value;
(level & AccessLevels.HistoryRead).ShouldBe(AccessLevels.HistoryRead,
"HistoryRead bit should be set");
}
finally
{
await fixture.DisposeAsync();
}
}
/// <summary>
/// Verifies that non-historized Galaxy attributes do not claim OPC UA history support.
/// </summary>
[Fact]
public async Task NormalAttribute_HasHistorizingFalse_AndNoHistoryReadAccess()
{
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(repo: CreateRepo());
await fixture.InitializeAsync();
try
{
using var client = new OpcUaTestClient();
await client.ConnectAsync(fixture.EndpointUrl);
var nodeId = client.MakeNodeId("TestObj.NormalAttr");
var historizing = client.ReadAttribute(nodeId, Attributes.Historizing);
((bool)historizing.Value).ShouldBeFalse();
var accessLevel = client.ReadAttribute(nodeId, Attributes.AccessLevel);
var level = (byte)accessLevel.Value;
(level & AccessLevels.HistoryRead).ShouldBe(0,
"HistoryRead bit should not be set");
}
finally
{
await fixture.DisposeAsync();
}
}
}
}