286ab3ba41
Adds PD (PID), MG (Message), PLS (Programmable Limit Switch) and BT
(Block Transfer) file types to the PCCC parser. New AbLegacyDataType
enum members (PidElement / MessageElement / PlsElement /
BlockTransferElement) plus per-type sub-element catalogue:
- PD: SP/PV/CV/KP/KI/KD/MAXS/MINS/DB/OUT as Float32; EN/DN/MO/PE/
AUTO/MAN/SP_VAL/SP_LL/SP_HL as Boolean (word-0 status bits).
- MG: RBE/MS/SIZE/LEN as Int32; EN/EW/ER/DN/ST/CO/NR/TO as Boolean.
- PLS: LEN as Int32 (bit table varies per PLC).
- BT: RLEN/DLEN as Int32; EN/ST/DN/ER/CO/EW/TO/NR as Boolean.
Per-family flags on AbLegacyPlcFamilyProfile gate availability:
- PD/MG: SLC500 + PLC-5 (operator + status bits both present).
- PLS/BT: PLC-5 only (chassis-IO block transfer is PLC-5-specific).
- MicroLogix + LogixPccc: rejected — no legacy file-letter form.
Status-bit indices match Rockwell DTAM / 1747-RM001 / 1785-6.5.12:
PD word 0 bits 0-8, MG/BT word 0 bits 8-15. PLC-set status bits
(PE/DN/SP_*; ST/DN/ER/CO/EW/NR/TO) are surfaced as ViewOnly via
IsPlcSetStatusBit, matching the Timer/Counter/Control pattern from
ablegacy-3.
LibplctagLegacyTagRuntime decodes PD non-bit members as Float32 and
MG/BT/PLS non-bit members as Int32; status bits route through GetBit
with the bit-position encoded by the driver via StatusBitIndex.
Tests: parser positive cases per family + negative cases per family,
catalogue + bit-index + read-only-bit assertions.
Closes #248
326 lines
15 KiB
C#
326 lines
15 KiB
C#
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||
|
||
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||
|
||
/// <summary>
|
||
/// PCCC data types that map onto SLC / MicroLogix / PLC-5 files. Narrower than Logix — no
|
||
/// symbolic UDTs; every type is file-typed and fixed-width.
|
||
/// </summary>
|
||
public enum AbLegacyDataType
|
||
{
|
||
/// <summary>B-file single bit (<c>B3:0/0</c>) or bit-within-N-file (<c>N7:0/3</c>).</summary>
|
||
Bit,
|
||
/// <summary>N-file integer (signed 16-bit).</summary>
|
||
Int,
|
||
/// <summary>L-file long integer — SLC 5/05+ only (signed 32-bit).</summary>
|
||
Long,
|
||
/// <summary>F-file float (32-bit IEEE-754).</summary>
|
||
Float,
|
||
/// <summary>A-file analog integer — some older hardware (signed 16-bit, semantically like N).</summary>
|
||
AnalogInt,
|
||
/// <summary>ST-file string (82-byte fixed-length + length word header).</summary>
|
||
String,
|
||
/// <summary>Timer sub-element — caller addresses <c>.ACC</c>, <c>.PRE</c>, <c>.EN</c>, <c>.DN</c>, <c>.TT</c>.</summary>
|
||
TimerElement,
|
||
/// <summary>Counter sub-element — caller addresses <c>.ACC</c>, <c>.PRE</c>, <c>.CU</c>, <c>.CD</c>, <c>.DN</c>.</summary>
|
||
CounterElement,
|
||
/// <summary>Control sub-element — caller addresses <c>.LEN</c>, <c>.POS</c>, <c>.EN</c>, <c>.DN</c>, <c>.ER</c>.</summary>
|
||
ControlElement,
|
||
/// <summary>
|
||
/// MicroLogix 1100/1400 function-file sub-element (RTC/HSC/DLS/MMI/PTO/PWM/STI/EII/IOS/BHI).
|
||
/// Sub-element catalogue lives in <see cref="AbLegacyFunctionFile.SubElementType"/>.
|
||
/// </summary>
|
||
MicroLogixFunctionFile,
|
||
/// <summary>
|
||
/// PD-file (PID) sub-element — caller addresses <c>.SP</c>, <c>.PV</c>, <c>.CV</c>,
|
||
/// <c>.KP</c>, <c>.KI</c>, <c>.KD</c>, <c>.MAXS</c>, <c>.MINS</c>, <c>.DB</c>, <c>.OUT</c>
|
||
/// (Float) and <c>.EN</c>, <c>.DN</c>, <c>.MO</c>, <c>.PE</c>, <c>.AUTO</c>, <c>.MAN</c>
|
||
/// (Boolean status bits in word 0).
|
||
/// </summary>
|
||
PidElement,
|
||
/// <summary>
|
||
/// MG-file (Message) sub-element — caller addresses <c>.RBE</c>, <c>.MS</c>, <c>.SIZE</c>,
|
||
/// <c>.LEN</c> (Int32) and <c>.EN</c>, <c>.EW</c>, <c>.ER</c>, <c>.DN</c>, <c>.ST</c>,
|
||
/// <c>.CO</c>, <c>.NR</c>, <c>.TO</c> (Boolean status bits).
|
||
/// </summary>
|
||
MessageElement,
|
||
/// <summary>
|
||
/// PLS-file (Programmable Limit Switch) sub-element — caller addresses <c>.LEN</c>
|
||
/// (Int32). Bit semantics vary by PLC; unknown sub-elements fall back to Int32.
|
||
/// </summary>
|
||
PlsElement,
|
||
/// <summary>
|
||
/// BT-file (Block Transfer) sub-element — caller addresses <c>.RLEN</c>, <c>.DLEN</c>
|
||
/// (Int32) and <c>.EN</c>, <c>.ST</c>, <c>.DN</c>, <c>.ER</c>, <c>.CO</c>, <c>.EW</c>,
|
||
/// <c>.TO</c>, <c>.NR</c> (Boolean status bits in word 0).
|
||
/// </summary>
|
||
BlockTransferElement,
|
||
}
|
||
|
||
/// <summary>
|
||
/// MicroLogix function-file sub-element catalogue. Covers the most-commonly-addressed members
|
||
/// per file — not exhaustive (Rockwell defines 30+ on RTC alone). Unknown sub-elements fall
|
||
/// back to <see cref="DriverDataType.Int32"/> at the <see cref="AbLegacyDataTypeExtensions"/>
|
||
/// boundary so the driver never refuses a tag the customer happens to know about.
|
||
/// </summary>
|
||
public static class AbLegacyFunctionFile
|
||
{
|
||
/// <summary>
|
||
/// Driver-surface type for <paramref name="fileLetter"/>.<paramref name="subElement"/>.
|
||
/// Returns <see cref="DriverDataType.Int32"/> if the sub-element is unrecognised — keeps
|
||
/// the driver permissive without forcing every quirk into the catalogue.
|
||
/// </summary>
|
||
public static DriverDataType SubElementType(string fileLetter, string? subElement)
|
||
{
|
||
if (subElement is null) return DriverDataType.Int32;
|
||
var key = (fileLetter.ToUpperInvariant(), subElement.ToUpperInvariant());
|
||
return key switch
|
||
{
|
||
// Real-time clock — all stored as Int16 (year is 4-digit Int16).
|
||
("RTC", "HR") or ("RTC", "MIN") or ("RTC", "SEC") or
|
||
("RTC", "MON") or ("RTC", "DAY") or ("RTC", "YR") or ("RTC", "DOW") => DriverDataType.Int32,
|
||
("RTC", "DS") or ("RTC", "BL") or ("RTC", "EN") => DriverDataType.Boolean,
|
||
|
||
// High-speed counter — accumulator/preset are Int32, status flags are bits.
|
||
("HSC", "ACC") or ("HSC", "PRE") or ("HSC", "OVF") or ("HSC", "UNF") => DriverDataType.Int32,
|
||
("HSC", "EN") or ("HSC", "UF") or ("HSC", "IF") or
|
||
("HSC", "IN") or ("HSC", "IH") or ("HSC", "IL") or
|
||
("HSC", "DN") or ("HSC", "CD") or ("HSC", "CU") => DriverDataType.Boolean,
|
||
|
||
// Daylight saving + memory module info.
|
||
("DLS", "STR") or ("DLS", "STD") => DriverDataType.Int32,
|
||
("DLS", "EN") => DriverDataType.Boolean,
|
||
("MMI", "FT") or ("MMI", "LBN") => DriverDataType.Int32,
|
||
("MMI", "MP") or ("MMI", "MCP") => DriverDataType.Boolean,
|
||
|
||
// Pulse-train / PWM output blocks.
|
||
("PTO", "ACC") or ("PTO", "OF") or ("PTO", "IDA") or ("PTO", "ODA") => DriverDataType.Int32,
|
||
("PTO", "EN") or ("PTO", "DN") or ("PTO", "EH") or ("PTO", "ED") or
|
||
("PTO", "RP") or ("PTO", "OUT") => DriverDataType.Boolean,
|
||
("PWM", "ACC") or ("PWM", "OF") or ("PWM", "PE") or ("PWM", "PD") => DriverDataType.Int32,
|
||
("PWM", "EN") or ("PWM", "DN") or ("PWM", "EH") or ("PWM", "ED") or
|
||
("PWM", "RP") or ("PWM", "OUT") => DriverDataType.Boolean,
|
||
|
||
// Selectable timed interrupt + event input interrupt.
|
||
("STI", "SPM") or ("STI", "ER") or ("STI", "PFN") => DriverDataType.Int32,
|
||
("STI", "EN") or ("STI", "TIE") or ("STI", "DN") or
|
||
("STI", "PS") or ("STI", "ED") => DriverDataType.Boolean,
|
||
("EII", "PFN") or ("EII", "ER") => DriverDataType.Int32,
|
||
("EII", "EN") or ("EII", "TIE") or ("EII", "PE") or
|
||
("EII", "ES") or ("EII", "ED") => DriverDataType.Boolean,
|
||
|
||
// I/O status + base hardware info — mostly status flags + a few counters.
|
||
("IOS", "ID") or ("IOS", "TYP") => DriverDataType.Int32,
|
||
("BHI", "OS") or ("BHI", "FRN") or ("BHI", "BSN") or ("BHI", "CC") => DriverDataType.Int32,
|
||
|
||
_ => DriverDataType.Int32,
|
||
};
|
||
}
|
||
}
|
||
|
||
/// <summary>Map a PCCC data type to the driver-surface <see cref="DriverDataType"/>.</summary>
|
||
public static class AbLegacyDataTypeExtensions
|
||
{
|
||
public static DriverDataType ToDriverDataType(this AbLegacyDataType t) => t switch
|
||
{
|
||
AbLegacyDataType.Bit => DriverDataType.Boolean,
|
||
AbLegacyDataType.Int or AbLegacyDataType.AnalogInt => DriverDataType.Int32,
|
||
AbLegacyDataType.Long => DriverDataType.Int32, // matches Modbus/AbCip 64→32 gap
|
||
AbLegacyDataType.Float => DriverDataType.Float32,
|
||
AbLegacyDataType.String => DriverDataType.String,
|
||
AbLegacyDataType.TimerElement or AbLegacyDataType.CounterElement
|
||
or AbLegacyDataType.ControlElement => DriverDataType.Int32,
|
||
AbLegacyDataType.MicroLogixFunctionFile => DriverDataType.Int32,
|
||
// PD/MG/PLS/BT default to Int32 at the parent-element level. The sub-element-aware
|
||
// EffectiveDriverDataType refines specific members (Float for PID gains, Boolean for
|
||
// status bits).
|
||
AbLegacyDataType.PidElement or AbLegacyDataType.MessageElement
|
||
or AbLegacyDataType.PlsElement or AbLegacyDataType.BlockTransferElement
|
||
=> DriverDataType.Int32,
|
||
_ => DriverDataType.Int32,
|
||
};
|
||
|
||
/// <summary>
|
||
/// Sub-element-aware driver type. Timer/Counter/Control elements expose Boolean status
|
||
/// bits (<c>.DN</c>, <c>.EN</c>, <c>.TT</c>, <c>.CU</c>, <c>.CD</c>, <c>.OV</c>,
|
||
/// <c>.UN</c>, <c>.ER</c>, etc.) and Int32 word members (<c>.PRE</c>, <c>.ACC</c>,
|
||
/// <c>.LEN</c>, <c>.POS</c>). Unknown sub-elements fall back to
|
||
/// <see cref="ToDriverDataType"/> so the driver remains permissive.
|
||
/// </summary>
|
||
public static DriverDataType EffectiveDriverDataType(AbLegacyDataType t, string? subElement)
|
||
{
|
||
if (subElement is null) return t.ToDriverDataType();
|
||
var key = subElement.ToUpperInvariant();
|
||
return t switch
|
||
{
|
||
AbLegacyDataType.TimerElement => key switch
|
||
{
|
||
"EN" or "TT" or "DN" => DriverDataType.Boolean,
|
||
"PRE" or "ACC" => DriverDataType.Int32,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
AbLegacyDataType.CounterElement => key switch
|
||
{
|
||
"CU" or "CD" or "DN" or "OV" or "UN" => DriverDataType.Boolean,
|
||
"PRE" or "ACC" => DriverDataType.Int32,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
AbLegacyDataType.ControlElement => key switch
|
||
{
|
||
"EN" or "EU" or "DN" or "EM" or "ER" or "UL" or "IN" or "FD" => DriverDataType.Boolean,
|
||
"LEN" or "POS" => DriverDataType.Int32,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
// PD-file (PID): SP/PV/CV/KP/KI/KD/MAXS/MINS/DB/OUT are 32-bit floats; EN/DN/MO/PE/
|
||
// AUTO/MAN/SP_VAL/SP_LL/SP_HL are status bits in word 0.
|
||
AbLegacyDataType.PidElement => key switch
|
||
{
|
||
"SP" or "PV" or "CV" or "KP" or "KI" or "KD"
|
||
or "MAXS" or "MINS" or "DB" or "OUT" => DriverDataType.Float32,
|
||
"EN" or "DN" or "MO" or "PE"
|
||
or "AUTO" or "MAN" or "SP_VAL" or "SP_LL" or "SP_HL" => DriverDataType.Boolean,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
// MG-file (Message): RBE/MS/SIZE/LEN are control words; EN/EW/ER/DN/ST/CO/NR/TO are
|
||
// status bits.
|
||
AbLegacyDataType.MessageElement => key switch
|
||
{
|
||
"RBE" or "MS" or "SIZE" or "LEN" => DriverDataType.Int32,
|
||
"EN" or "EW" or "ER" or "DN" or "ST" or "CO" or "NR" or "TO" => DriverDataType.Boolean,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
// PLS-file (Programmable Limit Switch): LEN is a length word; bit semantics vary by
|
||
// PLC so unknown sub-elements stay Int32.
|
||
AbLegacyDataType.PlsElement => key switch
|
||
{
|
||
"LEN" => DriverDataType.Int32,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
// BT-file (Block Transfer, PLC-5): RLEN/DLEN are length words; EN/ST/DN/ER/CO/EW/
|
||
// TO/NR are status bits in word 0.
|
||
AbLegacyDataType.BlockTransferElement => key switch
|
||
{
|
||
"RLEN" or "DLEN" => DriverDataType.Int32,
|
||
"EN" or "ST" or "DN" or "ER" or "CO" or "EW" or "TO" or "NR" => DriverDataType.Boolean,
|
||
_ => t.ToDriverDataType(),
|
||
},
|
||
_ => t.ToDriverDataType(),
|
||
};
|
||
}
|
||
|
||
/// <summary>
|
||
/// Bit position within the parent control word for Timer/Counter/Control status bits.
|
||
/// Returns <c>null</c> if the sub-element is not a known bit member of the given element
|
||
/// type. Bit numbering follows Rockwell DTAM / PCCC documentation.
|
||
/// </summary>
|
||
public static int? StatusBitIndex(AbLegacyDataType t, string? subElement)
|
||
{
|
||
if (subElement is null) return null;
|
||
var key = subElement.ToUpperInvariant();
|
||
return t switch
|
||
{
|
||
// T4 element word 0: bit 13=DN, 14=TT, 15=EN.
|
||
AbLegacyDataType.TimerElement => key switch
|
||
{
|
||
"DN" => 13,
|
||
"TT" => 14,
|
||
"EN" => 15,
|
||
_ => null,
|
||
},
|
||
// C5 element word 0: bit 10=UN, 11=OV, 12=DN, 13=CD, 14=CU.
|
||
AbLegacyDataType.CounterElement => key switch
|
||
{
|
||
"UN" => 10,
|
||
"OV" => 11,
|
||
"DN" => 12,
|
||
"CD" => 13,
|
||
"CU" => 14,
|
||
_ => null,
|
||
},
|
||
// R6 element word 0: bit 8=FD, 9=IN, 10=UL, 11=ER, 12=EM, 13=DN, 14=EU, 15=EN.
|
||
AbLegacyDataType.ControlElement => key switch
|
||
{
|
||
"FD" => 8,
|
||
"IN" => 9,
|
||
"UL" => 10,
|
||
"ER" => 11,
|
||
"EM" => 12,
|
||
"DN" => 13,
|
||
"EU" => 14,
|
||
"EN" => 15,
|
||
_ => null,
|
||
},
|
||
// PD element word 0 (SLC 5/02+ PID, 1747-RM001 / PLC-5 PID-RM): bit 0=EN, 1=PE,
|
||
// 2=DN, 3=MO (manual mode), 4=AUTO, 5=MAN, 6=SP_VAL, 7=SP_LL, 8=SP_HL. Bits 4–8 are
|
||
// the SP-validity / SP-limit flags exposed in RSLogix 5 / 500.
|
||
AbLegacyDataType.PidElement => key switch
|
||
{
|
||
"EN" => 0,
|
||
"PE" => 1,
|
||
"DN" => 2,
|
||
"MO" => 3,
|
||
"AUTO" => 4,
|
||
"MAN" => 5,
|
||
"SP_VAL" => 6,
|
||
"SP_LL" => 7,
|
||
"SP_HL" => 8,
|
||
_ => null,
|
||
},
|
||
// MG element word 0 (PLC-5 MSG / SLC 5/05 MSG, 1785-6.5.12 / 1747-RM001):
|
||
// bit 15=EN, 14=ST, 13=DN, 12=ER, 11=CO, 10=EW, 9=NR, 8=TO.
|
||
AbLegacyDataType.MessageElement => key switch
|
||
{
|
||
"TO" => 8,
|
||
"NR" => 9,
|
||
"EW" => 10,
|
||
"CO" => 11,
|
||
"ER" => 12,
|
||
"DN" => 13,
|
||
"ST" => 14,
|
||
"EN" => 15,
|
||
_ => null,
|
||
},
|
||
// BT element word 0 (PLC-5 chassis BTR/BTW, 1785-6.5.12):
|
||
// bit 15=EN, 14=ST, 13=DN, 12=ER, 11=CO, 10=EW, 9=NR, 8=TO. Same layout as MG.
|
||
AbLegacyDataType.BlockTransferElement => key switch
|
||
{
|
||
"TO" => 8,
|
||
"NR" => 9,
|
||
"EW" => 10,
|
||
"CO" => 11,
|
||
"ER" => 12,
|
||
"DN" => 13,
|
||
"ST" => 14,
|
||
"EN" => 15,
|
||
_ => null,
|
||
},
|
||
_ => null,
|
||
};
|
||
}
|
||
|
||
/// <summary>
|
||
/// PLC-set status bits — read-only from the OPC UA side. Operator-controllable bits
|
||
/// (e.g. <c>.EN</c> on a timer/counter, <c>.CU</c>/<c>.CD</c> rung-driven inputs) are
|
||
/// omitted so they keep default writable behaviour.
|
||
/// </summary>
|
||
public static bool IsPlcSetStatusBit(AbLegacyDataType t, string? subElement)
|
||
{
|
||
if (subElement is null) return false;
|
||
var key = subElement.ToUpperInvariant();
|
||
return t switch
|
||
{
|
||
AbLegacyDataType.TimerElement => key is "DN" or "TT",
|
||
AbLegacyDataType.CounterElement => key is "DN" or "OV" or "UN",
|
||
AbLegacyDataType.ControlElement => key is "DN" or "EM" or "ER" or "FD" or "UL" or "IN",
|
||
// PID: PE (PID-error), DN (process-done), SP_VAL/SP_LL/SP_HL are PLC-set status.
|
||
// EN/MO/AUTO/MAN are operator-controllable via the .EN bit / mode select.
|
||
AbLegacyDataType.PidElement => key is "PE" or "DN" or "SP_VAL" or "SP_LL" or "SP_HL",
|
||
// MG/BT: ST (started), DN (done), ER (error), CO (continuous), EW (enabled-waiting),
|
||
// NR (no-response), TO (timeout) are PLC-set. EN is operator-driven via the rung.
|
||
AbLegacyDataType.MessageElement => key is "ST" or "DN" or "ER" or "CO" or "EW" or "NR" or "TO",
|
||
AbLegacyDataType.BlockTransferElement => key is "ST" or "DN" or "ER" or "CO" or "EW" or "NR" or "TO",
|
||
_ => false,
|
||
};
|
||
}
|
||
}
|