- Driver.Modbus.Cli-003: ModbusCommandBase.ValidateEndpoint rejects
--port outside 1..65535, non-positive --timeout-ms, and --unit-id
outside 1..247.
- Driver.Modbus.Cli-004: wrapped SubscribeCommand's OnDataChange handler
body in a try/catch (warn-and-swallow) and serialised the console
write through a lock.
- Driver.Modbus.Cli-005: Probe / Read / Write now catch the
cancellation-during-init OperationCanceledException and print
'Cancelled.' instead of dumping a stack trace.
- Driver.Modbus.Cli-006: ProbeCommand.ComputeVerdict derives the headline
from BOTH the driver state and the probe snapshot's OPC UA quality
class so the headline can't disagree with the wire result.
- Driver.Modbus.Cli-007: docs/Driver.Modbus.Cli.md carries an explicit
'CLI scope' callout — the address-string grammar is a DriverConfig
JSON feature; the CLI takes the structured triple only.
- Driver.Modbus.Cli-008: pinned BuildOptions, ValidateEndpoint, the
region-validation guards, ComputeVerdict, and the cancellation-during-
initialize paths.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>