Files
lmxopcua/tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli.Tests/CommandMetadataTests.cs
T
Joseph Doherty b50fd6c34a review(Driver.AbLegacy.Cli): add FlushLogging() to command finally blocks
Re-review at 7286d320. -008 (Low): all four commands now FlushLogging() in finally (parity
with AbCip.Cli; subscribe could drop shutdown log lines) + IL-inspection test.
2026-06-19 12:08:45 -04:00

153 lines
7.2 KiB
C#

using System.Linq;
using System.Reflection;
using CliFx.Attributes;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli.Commands;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
/// <summary>
/// Locks in the CLI command-option contract surface area — short aliases and
/// help-text wording — that the AbLegacy CLI is expected to keep in parity with
/// its sibling AbCip CLI and with <c>docs/Driver.AbLegacy.Cli.md</c>.
/// Regression coverage for findings Driver.AbLegacy.Cli-002, -005, -006.
/// </summary>
[Trait("Category", "Unit")]
public sealed class CommandMetadataTests
{
private static CommandOptionAttribute GetOption<TCommand>(string propertyName)
{
var prop = typeof(TCommand).GetProperty(
propertyName,
BindingFlags.Public | BindingFlags.Instance);
prop.ShouldNotBeNull($"property {propertyName} is missing from {typeof(TCommand).Name}");
var attr = prop!.GetCustomAttribute<CommandOptionAttribute>();
attr.ShouldNotBeNull(
$"property {propertyName} on {typeof(TCommand).Name} lacks [CommandOption]");
return attr!;
}
// ---------- Driver.AbLegacy.Cli-006 — ProbeCommand --type needs short alias 't' ----------
/// <summary>Verifies that ProbeCommand --type has short alias -t.</summary>
[Fact]
public void ProbeCommand_type_has_short_alias_t()
{
// Parity with read / write / subscribe: --type / -t works everywhere.
var attr = GetOption<ProbeCommand>(nameof(ProbeCommand.DataType));
attr.ShortName.ShouldBe('t');
}
/// <summary>Verifies that other commands keep the --type short alias as -t.</summary>
/// <param name="commandType">The command type to inspect for the --type option.</param>
/// <param name="propName">The property name of the --type option on the command.</param>
[Theory]
[InlineData(typeof(ReadCommand), nameof(ReadCommand.DataType))]
[InlineData(typeof(WriteCommand), nameof(WriteCommand.DataType))]
[InlineData(typeof(SubscribeCommand), nameof(SubscribeCommand.DataType))]
public void Other_commands_keep_type_short_alias_t(System.Type commandType, string propName)
{
var prop = commandType.GetProperty(propName, BindingFlags.Public | BindingFlags.Instance);
prop.ShouldNotBeNull();
var attr = prop!.GetCustomAttribute<CommandOptionAttribute>();
attr.ShouldNotBeNull();
attr!.ShortName.ShouldBe('t');
}
// ---------- Driver.AbLegacy.Cli-002 — WriteCommand --value help lists full bool alias set ----------
/// <summary>Verifies that WriteCommand --value help lists the full boolean alias set.</summary>
[Fact]
public void WriteCommand_value_help_lists_full_boolean_alias_set()
{
// ParseBool accepts true/false, 1/0, on/off, yes/no — the help text must say so
// (DriverClis.md documents the full alias set as the shared CLI contract).
var attr = GetOption<WriteCommand>(nameof(WriteCommand.Value));
attr.Description.ShouldNotBeNull();
attr.Description!.ShouldContain("true/false", Case.Insensitive);
attr.Description!.ShouldContain("1/0");
attr.Description!.ShouldContain("on/off", Case.Insensitive);
attr.Description!.ShouldContain("yes/no", Case.Insensitive);
}
// ---------- Driver.AbLegacy.Cli-005 — SubscribeCommand --interval-ms help notes 250ms floor ----------
/// <summary>Verifies that SubscribeCommand --interval-ms help notes the PollGroupEngine floor.</summary>
[Fact]
public void SubscribeCommand_interval_ms_help_notes_PollGroupEngine_floor()
{
// Parity with AbCip CLI: operators passing -i 100 deserve a heads-up that
// PollGroupEngine floors sub-250ms values.
var attr = GetOption<SubscribeCommand>(nameof(SubscribeCommand.IntervalMs));
attr.Description.ShouldNotBeNull();
attr.Description!.ShouldContain("250", Case.Insensitive);
}
// ---------- Driver.AbLegacy.Cli-008 — all commands must call FlushLogging() in their finally ----------
/// <summary>
/// Verifies that every AbLegacy CLI command's async state-machine references
/// <see cref="DriverCommandBase.FlushLogging"/> so Serilog output emitted during
/// driver shutdown is flushed before process exit (regression for
/// Driver.AbLegacy.Cli-008, matching the fix applied to AbCip CLI Driver.AbCip.Cli-005).
/// </summary>
/// <param name="commandType">The command type whose state machine is inspected.</param>
[Theory]
[InlineData(typeof(ProbeCommand))]
[InlineData(typeof(ReadCommand))]
[InlineData(typeof(WriteCommand))]
[InlineData(typeof(SubscribeCommand))]
public void ExecuteAsync_calls_FlushLogging_in_state_machine(System.Type commandType)
{
// C# async methods are compiled into a nested '<ExecuteAsync>d__N' state machine
// class with a MoveNext() method that contains the actual IL. We scan the
// MoveNext() body for a call token that resolves to DriverCommandBase.FlushLogging
// using the module's metadata.
var flushMethod = typeof(DriverCommandBase)
.GetMethod("FlushLogging",
BindingFlags.NonPublic | BindingFlags.Static | BindingFlags.FlattenHierarchy);
flushMethod.ShouldNotBeNull("DriverCommandBase.FlushLogging must exist");
// Locate the compiler-generated state-machine nested type for ExecuteAsync.
var stateMachine = commandType
.GetNestedTypes(BindingFlags.NonPublic)
.FirstOrDefault(t => t.Name.Contains("ExecuteAsync"));
stateMachine.ShouldNotBeNull(
$"{commandType.Name} must have a compiler-generated ExecuteAsync state machine");
var moveNext = stateMachine!
.GetMethod("MoveNext", BindingFlags.NonPublic | BindingFlags.Instance);
moveNext.ShouldNotBeNull("MoveNext must exist on the state machine");
var body = moveNext!.GetMethodBody();
body.ShouldNotBeNull("MoveNext must have an inspectable method body");
// Walk the IL stream: call/callvirt opcodes (0x28 / 0x6F) are followed by a
// 4-byte metadata token. Check whether any token resolves to FlushLogging.
var il = body!.GetILAsByteArray();
il.ShouldNotBeNull();
var module = moveNext.Module;
bool found = false;
for (int i = 0; i < il!.Length - 4; i++)
{
if (il[i] != 0x28 && il[i] != 0x6F) continue; // call / callvirt
int token = il[i + 1] | (il[i + 2] << 8) | (il[i + 3] << 16) | (il[i + 4] << 24);
try
{
var resolved = module.ResolveMethod(token);
if (resolved?.Name == "FlushLogging" &&
resolved.DeclaringType == typeof(DriverCommandBase))
{
found = true;
break;
}
}
catch (ArgumentException) { /* token is a field or type, not a method */ }
}
found.ShouldBeTrue(
$"{commandType.Name}.ExecuteAsync must call FlushLogging() in its finally block " +
"so Serilog output during driver shutdown is not lost (Driver.AbLegacy.Cli-008).");
}
}