d50ee809e3
Native LSV2 TCP transport (default port 19000; no Java/Python/vendor SDK), ported from the ignitionoee v0.20.3 reference driver: - Lsv2ReadOnlyPolicy: payload-aware outbound allowlist (A_LG INSPECT/DNC/DATA, R_VR, R_PR, R_RI 22-28/30-34/51, bounded R_MB, R_DP), applied in Lsv2Codec.Frame before any byte is written; no public raw-command API. - Lsv2Client: serialized transactions, one monotonic deadline per transaction, EOF/oversize/ unexpected/trickle close the client; Close never waits on the gate. - Lsv2Data / HeidenhainBindingCodec: reference decoders, R_PR byte-capacity + element-index rules, next-area cap, DATA Boolean 00/01/FF, strict non-truncating coercion. - HeidenhainSession: per-batch wire cache, refusal suppression, provisional DNC denial retry, alarm cursor (57 = end, overflow = BadOutOfRange), capability strings. - HeidenhainDeviceRuntime: one loop per control, generation-guarded publication, all-node BadNoCommunication on comms loss, bounded exponential reconnect. - HeidenhainDriver: cached ReadAsync, push subscriptions deduped on (value,status), static catalog discovery (no connect), host status, diagnostics, skipped-tag report. No IWritable. - Probe (INSPECT login + version) and factory registered in DriverFactoryBootstrap (probe on admin nodes too); DriverTypeNames.Heidenhain. Tests: 159 unit tests against an in-process LSV2 simulator incl. the Java fixtures' captured iTNC 530 replies as golden vectors; env-gated LiveIntegration category for real hardware.
77 lines
4.1 KiB
C#
77 lines
4.1 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Lsv2;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests.Simulator;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests;
|
|
|
|
/// <summary>
|
|
/// Replays the actual DATA boundary replies captured on three iTNC 530 controls (reference
|
|
/// <c>HeidenhainPlcUnitsTest</c>): R_PR numeric counts are BYTE capacities, binding indexes are ELEMENT
|
|
/// indexes, and the DATA Boolean FF encoding is accepted.
|
|
/// </summary>
|
|
[Trait("Category", "Unit")]
|
|
public sealed class HeidenhainPlcUnitsTests
|
|
{
|
|
private static CancellationToken Ct => TestContext.Current.CancellationToken;
|
|
|
|
[Theory]
|
|
[InlineData("hermle59")]
|
|
[InlineData("hermle70")]
|
|
[InlineData("hermle29")]
|
|
public async Task Real_boundaries_match_region_byte_counts_and_element_widths(string machine)
|
|
{
|
|
var f = Fixtures.Load("plc-count-units.properties");
|
|
var control = new SimulatedControl
|
|
{
|
|
Version = Convert.FromHexString(f[machine + ".version"]),
|
|
Layout = Convert.FromHexString(f[machine + ".layout"]),
|
|
};
|
|
foreach (var (key, value) in f)
|
|
{
|
|
if (!key.StartsWith(machine + ".", StringComparison.Ordinal) || key.EndsWith(".version", StringComparison.Ordinal) || key.EndsWith(".layout", StringComparison.Ordinal)) continue;
|
|
var parts = key.Split('.');
|
|
control.DataPaths[$"/PLC/memory/{parts[1]}/{parts[2]}"] = SimReply.FromFixture(value);
|
|
}
|
|
|
|
await using var sim = Lsv2Simulator.WithControl(control);
|
|
await using var client = new Lsv2Client("127.0.0.1", sim.Port, TimeSpan.FromSeconds(1));
|
|
await client.OpenAsync(Ct);
|
|
await client.LoginAsync("INSPECT", "", Ct);
|
|
await client.LoginAsync("DATA", "", Ct);
|
|
var layout = Lsv2Data.Layout(await client.ReadParametersAsync(Ct));
|
|
|
|
foreach (var (token, area) in new[] { ("B", HeidenhainPlcArea.Byte), ("W", HeidenhainPlcArea.Word), ("D", HeidenhainPlcArea.Dword), ("IW", HeidenhainPlcArea.InputWord), ("OW", HeidenhainPlcArea.OutputWord) })
|
|
{
|
|
var region = layout.Region(area)!;
|
|
long expectedBytes = token.Length == 1 ? 10000 : 1000;
|
|
region.Bytes.ShouldBe(expectedBytes, $"{machine} {area}");
|
|
var lastOffset = expectedBytes - region.Width;
|
|
Lsv2Data.DataPath(await client.ReadDataPathAsync($"/PLC/memory/{token}/{lastOffset}", Ct)).ShouldNotBeNull();
|
|
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/{expectedBytes}", Ct))).Code.ShouldBe(24);
|
|
HeidenhainBindingCodec.Range(area, lastOffset / region.Width, layout).Address.ShouldBe(region.Base + lastOffset);
|
|
Should.Throw<HeidenhainRangeException>(() => HeidenhainBindingCodec.Range(area, lastOffset / region.Width + 1, layout));
|
|
}
|
|
|
|
foreach (var token in new[] { "W", "D", "IW", "OW" })
|
|
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/1", Ct))).Code.ShouldBe(24);
|
|
|
|
foreach (var (token, area, entries) in new[]
|
|
{
|
|
("M", HeidenhainPlcArea.Marker, 10000), ("I", HeidenhainPlcArea.Input, 1000), ("O", HeidenhainPlcArea.Output, 1000),
|
|
("C", HeidenhainPlcArea.Counter, 144), ("T", HeidenhainPlcArea.Timer, 1000), ("S", HeidenhainPlcArea.String, 100),
|
|
})
|
|
{
|
|
var region = layout.Region(area)!;
|
|
region.Bytes.ShouldBe((long)entries * region.Width);
|
|
Lsv2Data.DataPath(await client.ReadDataPathAsync($"/PLC/memory/{token}/{entries - 1}", Ct)).ShouldNotBeNull();
|
|
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/{entries}", Ct))).Code.ShouldBe(24);
|
|
}
|
|
|
|
// Observed FF-true on a real output slot.
|
|
if (f.TryGetValue(machine + ".O.999", out var o999) && o999.EndsWith("ff", StringComparison.OrdinalIgnoreCase))
|
|
Lsv2Data.DataPath(await client.ReadDataPathAsync("/PLC/memory/O/999", Ct)).ShouldBe(true);
|
|
control.Violations.ShouldBeEmpty();
|
|
}
|
|
}
|