Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests/HeidenhainPlcUnitsTests.cs
T
Joseph Doherty d50ee809e3 feat(heidenhain): native read-only LSV2 driver + in-process simulator (#803)
Native LSV2 TCP transport (default port 19000; no Java/Python/vendor SDK), ported from
the ignitionoee v0.20.3 reference driver:

- Lsv2ReadOnlyPolicy: payload-aware outbound allowlist (A_LG INSPECT/DNC/DATA, R_VR, R_PR,
  R_RI 22-28/30-34/51, bounded R_MB, R_DP), applied in Lsv2Codec.Frame before any byte is
  written; no public raw-command API.
- Lsv2Client: serialized transactions, one monotonic deadline per transaction, EOF/oversize/
  unexpected/trickle close the client; Close never waits on the gate.
- Lsv2Data / HeidenhainBindingCodec: reference decoders, R_PR byte-capacity + element-index
  rules, next-area cap, DATA Boolean 00/01/FF, strict non-truncating coercion.
- HeidenhainSession: per-batch wire cache, refusal suppression, provisional DNC denial retry,
  alarm cursor (57 = end, overflow = BadOutOfRange), capability strings.
- HeidenhainDeviceRuntime: one loop per control, generation-guarded publication, all-node
  BadNoCommunication on comms loss, bounded exponential reconnect.
- HeidenhainDriver: cached ReadAsync, push subscriptions deduped on (value,status), static
  catalog discovery (no connect), host status, diagnostics, skipped-tag report. No IWritable.
- Probe (INSPECT login + version) and factory registered in DriverFactoryBootstrap (probe on
  admin nodes too); DriverTypeNames.Heidenhain.

Tests: 159 unit tests against an in-process LSV2 simulator incl. the Java fixtures' captured
iTNC 530 replies as golden vectors; env-gated LiveIntegration category for real hardware.
2026-11-10 23:08:30 -05:00

77 lines
4.1 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Lsv2;
using ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests.Simulator;
namespace ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests;
/// <summary>
/// Replays the actual DATA boundary replies captured on three iTNC 530 controls (reference
/// <c>HeidenhainPlcUnitsTest</c>): R_PR numeric counts are BYTE capacities, binding indexes are ELEMENT
/// indexes, and the DATA Boolean FF encoding is accepted.
/// </summary>
[Trait("Category", "Unit")]
public sealed class HeidenhainPlcUnitsTests
{
private static CancellationToken Ct => TestContext.Current.CancellationToken;
[Theory]
[InlineData("hermle59")]
[InlineData("hermle70")]
[InlineData("hermle29")]
public async Task Real_boundaries_match_region_byte_counts_and_element_widths(string machine)
{
var f = Fixtures.Load("plc-count-units.properties");
var control = new SimulatedControl
{
Version = Convert.FromHexString(f[machine + ".version"]),
Layout = Convert.FromHexString(f[machine + ".layout"]),
};
foreach (var (key, value) in f)
{
if (!key.StartsWith(machine + ".", StringComparison.Ordinal) || key.EndsWith(".version", StringComparison.Ordinal) || key.EndsWith(".layout", StringComparison.Ordinal)) continue;
var parts = key.Split('.');
control.DataPaths[$"/PLC/memory/{parts[1]}/{parts[2]}"] = SimReply.FromFixture(value);
}
await using var sim = Lsv2Simulator.WithControl(control);
await using var client = new Lsv2Client("127.0.0.1", sim.Port, TimeSpan.FromSeconds(1));
await client.OpenAsync(Ct);
await client.LoginAsync("INSPECT", "", Ct);
await client.LoginAsync("DATA", "", Ct);
var layout = Lsv2Data.Layout(await client.ReadParametersAsync(Ct));
foreach (var (token, area) in new[] { ("B", HeidenhainPlcArea.Byte), ("W", HeidenhainPlcArea.Word), ("D", HeidenhainPlcArea.Dword), ("IW", HeidenhainPlcArea.InputWord), ("OW", HeidenhainPlcArea.OutputWord) })
{
var region = layout.Region(area)!;
long expectedBytes = token.Length == 1 ? 10000 : 1000;
region.Bytes.ShouldBe(expectedBytes, $"{machine} {area}");
var lastOffset = expectedBytes - region.Width;
Lsv2Data.DataPath(await client.ReadDataPathAsync($"/PLC/memory/{token}/{lastOffset}", Ct)).ShouldNotBeNull();
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/{expectedBytes}", Ct))).Code.ShouldBe(24);
HeidenhainBindingCodec.Range(area, lastOffset / region.Width, layout).Address.ShouldBe(region.Base + lastOffset);
Should.Throw<HeidenhainRangeException>(() => HeidenhainBindingCodec.Range(area, lastOffset / region.Width + 1, layout));
}
foreach (var token in new[] { "W", "D", "IW", "OW" })
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/1", Ct))).Code.ShouldBe(24);
foreach (var (token, area, entries) in new[]
{
("M", HeidenhainPlcArea.Marker, 10000), ("I", HeidenhainPlcArea.Input, 1000), ("O", HeidenhainPlcArea.Output, 1000),
("C", HeidenhainPlcArea.Counter, 144), ("T", HeidenhainPlcArea.Timer, 1000), ("S", HeidenhainPlcArea.String, 100),
})
{
var region = layout.Region(area)!;
region.Bytes.ShouldBe((long)entries * region.Width);
Lsv2Data.DataPath(await client.ReadDataPathAsync($"/PLC/memory/{token}/{entries - 1}", Ct)).ShouldNotBeNull();
(await Should.ThrowAsync<Lsv2RefusalException>(() => client.ReadDataPathAsync($"/PLC/memory/{token}/{entries}", Ct))).Code.ShouldBe(24);
}
// Observed FF-true on a real output slot.
if (f.TryGetValue(machine + ".O.999", out var o999) && o999.EndsWith("ff", StringComparison.OrdinalIgnoreCase))
Lsv2Data.DataPath(await client.ReadDataPathAsync("/PLC/memory/O/999", Ct)).ShouldBe(true);
control.Violations.ShouldBeEmpty();
}
}