Files
lmxopcua/docs/drivers/README.md
Joseph Doherty 4b0664bd55 FOCAS — retire Tier-C split, inline managed wire client, make read-only
Migration closes the FOCAS Tier-C architecture. OtOpcUa previously had
`Driver.FOCAS.Host` (NSSM-wrapped Windows service loading Fwlib64.dll via
P/Invoke) + `Driver.FOCAS.Shared` (MessagePack IPC contracts) + a C shim
DLL stand-in for unit tests. All of it is deleted; the driver is now a
single in-process managed assembly talking the FOCAS/2 Ethernet binary
protocol directly on TCP:8193.

Architecture

- Pure-managed `FocasWireClient` inlined at `src/.../Driver.FOCAS/Wire/`
  (owner-imported — see Wire/FocasWireClient.cs for the full surface).
  Opens two TCP sockets, runs the initiate handshake, serialises requests
  on socket 2 through a semaphore, closes cleanly with PDU + socket
  teardown. Both sync `IDisposable` and async `IAsyncDisposable`.
- `WireFocasClient` (same folder) adapts the wire client to OtOpcUa's
  `IFocasClient` surface — fixed-tree reads, PARAM/MACRO/PMC addresses,
  alarms. Writes return `BadNotWritable` by design — OtOpcUa is read-only
  against FOCAS.
- `FocasDriverFactoryExtensions` now accepts `"Backend": "wire"` (default)
  and `"Backend": "unimplemented"`. Legacy `ipc` and `fwlib` backends are
  rejected at startup with a diagnostic pointing at the migration doc.

Deletions

- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Host/` — whole project + Ipc/,
  Backend/, Stability/, Program.cs.
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Shared/` — Contracts/, FrameReader,
  FrameWriter, whole project.
- `tests/...Driver.FOCAS.Host.Tests/` + `.Shared.Tests/` — whole projects.
- `src/.../Driver.FOCAS/FwlibNative.cs` + `FwlibFocasClient.cs` — 21
  P/Invokes + 7 `Pack=1` marshalling structs + the Fwlib-backed
  `IFocasClient` implementation.
- `src/.../Driver.FOCAS/Ipc/` + `Supervisor/` — IPC client wrapper +
  Host-process supervisor (backoff, circuit breaker, heartbeat, post-
  mortem reader, process launcher).
- `scripts/install/Install-FocasHost.ps1` — NSSM service installer.
- `tests/.../Driver.FOCAS.Tests/{IpcFocasClientTests, IpcLoopback,
  FwlibNativeHelperTests, PostMortemReaderCompatibilityTests,
  SupervisorTests, FocasDriverFactoryExtensionsTests}.cs` — tests that
  exercised the retired surfaces.
- `tests/.../Driver.FOCAS.IntegrationTests/Shim/` — the zig-built C shim
  DLL that masqueraded as Fwlib64.dll.

Solution changes

- `ZB.MOM.WW.OtOpcUa.slnx` drops the 4 retired project refs.
- `src/.../Driver.FOCAS.csproj` drops the Shared ProjectReference, adds
  `Microsoft.Extensions.Logging.Abstractions` for the optional `ILogger`
  hook in `FocasWireClient`.
- `src/.../Driver.FOCAS.Cli.csproj` drops the six `<Content Include>`
  entries that copied `vendor/fanuc/*.dll` into the CLI bin. CLI now uses
  `WireFocasClient` directly.
- `FocasDriver` default factory flips to `Wire.WireFocasClientFactory`.

Integration tests

- New `tests/.../Driver.FOCAS.IntegrationTests/` project covering fixed-
  tree reads (identity, axes, dynamic, program, operation mode, timers,
  spindle load + max RPM, servo meters), user-authored PARAM / MACRO /
  PMC reads, `DiscoverAsync` emission, `SubscribeAsync` + `OnDataChange`,
  `IAlarmSource` raise/clear transitions, and `ProbeAsync` /
  `OnHostStatusChanged`. 9 e2e tests against the focas-mock fixture
  (Docker container with the vendored Python mock's native FOCAS/2
  Ethernet responder).
- `scripts/integration/run-focas.ps1` orchestrates compose up → tests →
  compose down. Dropped the shim-build stage + DLL-copy step + the split
  testhost workaround (the latter only existed because of native-DLL
  lifecycle bugs the shim tripped).
- Docker compose collapses from 11 per-series services to one `focas-sim`
  service. Tests seed per-series state via `mock_load_profile` at test
  start.
- Vendored focas-mock snapshot refreshed to pick up upstream's native
  FOCAS/2 Ethernet responder (was 660 lines, now 1018) — the
  pre-refresh snapshot only spoke the JSON admin protocol.

Tests

- 145/145 unit tests in `Driver.FOCAS.Tests` pass (was 208 pre-deletion;
  63 removed tests exercised the retired IPC/shim/supervisor/Fwlib
  surfaces).
- 9/9 integration tests pass against the refreshed mock.
- `FocasScaffoldingTests.Unimplemented_factory_throws_on_Create…` updated
  to assert the new diagnostic message pointing at
  `docs/drivers/FOCAS.md` rather than the now-gone `Fwlib64.dll`.

Docs

- `docs/drivers/FOCAS.md` rewritten for the managed wire topology —
  deployment collapses to one `"Backend": "wire"` config block, no
  separate service, no DLL deployment, no pipe ACL.
- `docs/drivers/FOCAS-Test-Fixture.md` updated — single TCP probe skip
  gate instead of TCP + shim probe; fewer moving parts.
- `docs/drivers/README.md` row for FOCAS reflects the Tier-A managed
  topology (previously listed Tier-C + `Fwlib64.dll` P/Invoke).
- `docs/Driver.FOCAS.Cli.md` drops the Tier-C architecture-note section.
- `docs/v2/implementation/focas-isolation-plan.md` marked historical —
  the plan it documents was executed then superseded by the wire client.
- `docs/v2/v2-release-readiness.md` re-audited 2026-04-24. Phase 5
  driver complement closed. FOCAS change-log entry added.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-24 14:10:59 -04:00

8.6 KiB
Raw Blame History

Drivers

OtOpcUa is a multi-driver OPC UA server. The Core (ZB.MOM.WW.OtOpcUa.Core + Core.Abstractions + Server) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through capability interfaces defined in src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/:

  • IDriver — lifecycle (InitializeAsync, ReinitializeAsync, ShutdownAsync, GetHealth)
  • IReadable / IWritable — one-shot reads and writes
  • ITagDiscovery — address-space enumeration
  • ISubscribable — driver-pushed data-change streams
  • IHostConnectivityProbe — per-host reachability events
  • IPerCallHostResolver — multi-host drivers that route each call to a target endpoint at dispatch time
  • IAlarmSource — driver-emitted OPC UA A&C events
  • IHistoryProvider — raw / processed / at-time / events HistoryRead (see HistoricalDataAccess.md)
  • IRediscoverable — driver-initiated address-space rebuild notifications

Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through CapabilityInvoker (Core/Resilience/CapabilityInvoker.cs), which wraps it in a Polly pipeline keyed on (DriverInstanceId, HostName, DriverCapability). The OTOPCUA0001 analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.

Driver type metadata is registered at startup in DriverTypeRegistry (src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs). The registry records each type's allowed namespace kinds (Equipment / SystemPlatform / Simulated), its JSON Schema for DriverConfig / DeviceConfig / TagConfig columns, and its stability tier per docs/v2/driver-stability.md.

Ground-truth driver list

Driver Project path Tier Wire / library Capabilities Notable quirk
Galaxy Driver.Galaxy.{Shared, Host, Proxy} C MXAccess COM + aahClientManaged + SqlClient IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe Out-of-process — Host is its own Windows service (.NET 4.8 x86 for the COM bitness constraint); Proxy talks to Host over a named pipe
Modbus TCP Driver.Modbus A NModbus-derived in-house client IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe Polled subscriptions via the shared PollGroupEngine. DL205 PLCs are covered by AddressFormat=DL205 (octal V/X/Y/C/T/CT translation) — no separate driver
Siemens S7 Driver.S7 A S7netplus IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe Single S7netplus Plc instance per PLC serialized with SemaphoreSlim — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help
AB CIP Driver.AbCip A libplctag CIP IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource ControlLogix / CompactLogix. Tag discovery uses the @tags walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader
AB Legacy Driver.AbLegacy A libplctag PCCC IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver SLC 500 / MicroLogix. File-based addressing (N7:0, F8:0) — no symbol table, tag list is user-authored in the config DB
TwinCAT Driver.TwinCAT B Beckhoff TwinCAT.Ads (TcAdsClient) IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver The only native-notification driver outside Galaxy — ADS delivers ValueChangedCallback events the driver forwards straight to ISubscribable.OnDataChange without polling. Symbol tree uploaded via SymbolLoaderFactory
FOCAS Driver.FOCAS A Pure-managed FocasWireClient — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource Read-only by design (WriteAsync returns BadNotWritable). CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed
OPC UA Client Driver.OpcUaClient B OPCFoundation Opc.Ua.Client IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe Gateway/aggregation driver. Opens a single Session against a remote OPC UA server and re-exposes its address space. Owns its own ApplicationConfiguration (distinct from Client.Shared) because it's always-on with keep-alive + TransferSubscriptions across SDK reconnect, not an interactive CLI

Per-driver documentation

  • Galaxy has its own docs in this folder because the out-of-process architecture + MXAccess COM rules + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:

  • FOCAS has a short getting-started doc because the Tier-C two-project deployment + backend-selection env var + alarm projection opt-in all need explaining up front:

    • FOCAS.md — deployment, config, capability surface, alarm projection, troubleshooting
  • All other drivers share a single per-driver specification in docs/v2/driver-specs.md — addressing, data-type maps, connection settings, and quirks live there. That file is the authoritative per-driver reference; this index points at it rather than duplicating.

Test-fixture coverage maps

Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.

  • AB CIP — Dockerized ab_server (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
  • Modbus — Dockerized pymodbus + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
  • Siemens S7 — Dockerized python-snap7 server; DB/MB read + write round-trip verified end-to-end on :1102
  • AB Legacy — Dockerized ab_server PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. /1,0 cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (B3:0/5) still surface BadState — real HW / RSEmulate 500 for those
  • TwinCAT — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via FakeTwinCATClient with native-notification harness
  • FOCAS — no integration fixture, unit-only via FakeFocasClient; Tier C out-of-process isolation scoped but not shipped
  • OPC UA Client — no integration fixture, unit-only via mocked Session; loopback against this repo's own server is the obvious next step
  • Galaxy — richest harness: E2E Host subprocess + ZB SQL live-smoke + MXAccess opt-in
  • HistoricalDataAccess.mdIHistoryProvider dispatch, aggregate mapping, continuation points. The Galaxy driver's Aveva Historian implementation is the first; OPC UA Client forwards to the upstream server; other drivers do not implement the interface and return BadHistoryOperationUnsupported.
  • AlarmTracking.mdIAlarmSource event model and filtering.
  • Subscriptions.md — how the Server multiplexes subscriptions onto ISubscribable.OnDataChange.
  • docs/v2/driver-stability.md — tier system (A / B / C), shared CapabilityPolicy defaults per tier × capability, MemoryTracking hybrid formula, and process-level recycle rules.
  • docs/v2/plan.md — authoritative vision, architecture decisions, migration strategy.