Files
lmxopcua/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusDriverFactoryExtensions.cs
Joseph Doherty aafb9d4929 v3(b1-modbus): RawPath identity seam — RawTagEntry-driven Modbus driver
Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now
builds its RawPath -> definition table from the artifact's RawTagEntry set via a
pure mapper.

- Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory;
  TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath,
  no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all
  strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited
  so a RawTagEntry round-trips the full authored def. Inspect() unchanged.
- Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>).
- Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build
  the table from RawTags at Initialize threading entry.WriteIdempotent onto each def;
  Discover/Teardown updated.
- Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind
  RawTags from driver-config JSON.
- CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig.
- Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests ->
  FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam.
- Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects).

Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green.
Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against
the new API; expected).
2026-07-15 19:50:10 -04:00

214 lines
12 KiB
C#

using System.Text.Json;
using System.Text.Json.Serialization;
using Microsoft.Extensions.Logging;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
using ZB.MOM.WW.OtOpcUa.Core.Hosting;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
/// <summary>
/// Static factory registration helper for <see cref="ModbusDriver"/>. Server's Program.cs
/// calls <see cref="Register"/> once at startup; the bootstrapper then
/// materialises Modbus DriverInstance rows from the central config DB into live driver
/// instances. Mirrors <c>GalaxyProxyDriverFactoryExtensions</c> / <c>FocasDriverFactoryExtensions</c>.
/// </summary>
public static class ModbusDriverFactoryExtensions
{
public const string DriverTypeName = "Modbus";
/// <summary>
/// Register the Modbus factory with the driver registry. The optional
/// <paramref name="loggerFactory"/> is captured at registration time and used to
/// construct an <see cref="ILogger{ModbusDriver}"/> per driver instance — without it,
/// the driver runs with the null logger (existing tests and standalone callers stay
/// unchanged).
/// </summary>
/// <param name="registry">The driver factory registry to register with.</param>
/// <param name="loggerFactory">Optional logger factory for creating loggers per driver instance.</param>
public static void Register(DriverFactoryRegistry registry, ILoggerFactory? loggerFactory = null)
{
ArgumentNullException.ThrowIfNull(registry);
registry.Register(DriverTypeName, (id, json) => CreateInstance(id, json, loggerFactory));
}
/// <summary>Public for the Server-side bootstrapper + test consumers (Admin.Tests, etc.).</summary>
/// <param name="driverInstanceId">The unique identifier for the driver instance.</param>
/// <param name="driverConfigJson">The JSON configuration string for the driver.</param>
/// <returns>The constructed <see cref="ModbusDriver"/> instance.</returns>
public static ModbusDriver CreateInstance(string driverInstanceId, string driverConfigJson)
=> CreateInstance(driverInstanceId, driverConfigJson, loggerFactory: null);
/// <summary>Logger-aware overload — used by <see cref="Register"/>'s closure when wired through DI.</summary>
/// <param name="driverInstanceId">The unique identifier for the driver instance.</param>
/// <param name="driverConfigJson">The JSON configuration string for the driver.</param>
/// <param name="loggerFactory">Optional logger factory for creating loggers per driver instance.</param>
/// <returns>The constructed <see cref="ModbusDriver"/> instance.</returns>
public static ModbusDriver CreateInstance(string driverInstanceId, string driverConfigJson, ILoggerFactory? loggerFactory)
{
ArgumentException.ThrowIfNullOrWhiteSpace(driverInstanceId);
ArgumentException.ThrowIfNullOrWhiteSpace(driverConfigJson);
var dto = JsonSerializer.Deserialize<ModbusDriverConfigDto>(driverConfigJson, JsonOptions)
?? throw new InvalidOperationException(
$"Modbus driver config for '{driverInstanceId}' deserialised to null");
if (string.IsNullOrWhiteSpace(dto.Host))
throw new InvalidOperationException(
$"Modbus driver config for '{driverInstanceId}' missing required Host");
var options = new ModbusDriverOptions
{
Host = dto.Host!,
Port = dto.Port ?? 502,
UnitId = dto.UnitId ?? 1,
Timeout = TimeSpan.FromMilliseconds(dto.TimeoutMs ?? 2_000),
MaxRegistersPerRead = dto.MaxRegistersPerRead ?? 125,
MaxRegistersPerWrite = dto.MaxRegistersPerWrite ?? 123,
MaxCoilsPerRead = dto.MaxCoilsPerRead ?? 2000,
UseFC15ForSingleCoilWrites = dto.UseFC15ForSingleCoilWrites ?? false,
UseFC16ForSingleRegisterWrites = dto.UseFC16ForSingleRegisterWrites ?? false,
DisableFC23 = dto.DisableFC23 ?? false,
WriteOnChangeOnly = dto.WriteOnChangeOnly ?? false,
MaxReadGap = dto.MaxReadGap ?? 0,
Family = dto.Family is null ? ModbusFamily.Generic
: ParseEnum<ModbusFamily>(dto.Family, "<driver-level>", driverInstanceId, "Family"),
MelsecSubFamily = dto.MelsecSubFamily is null ? MelsecFamily.Q_L_iQR
: ParseEnum<MelsecFamily>(dto.MelsecSubFamily, "<driver-level>", driverInstanceId, "MelsecSubFamily"),
AutoProhibitReprobeInterval = dto.AutoProhibitReprobeMs is { } reprobeMs ? TimeSpan.FromMilliseconds(reprobeMs) : null,
AutoReconnect = dto.AutoReconnect ?? true,
// v3: the deploy artifact (Wave C) populates rawTags with the cluster's authored raw Modbus
// tags. The driver maps each RawTagEntry's TagConfig blob through ModbusTagDefinitionFactory
// at Initialize; the legacy pre-declared DTO tag path (structured/AddressString → BuildTag)
// is retired.
RawTags = dto.RawTags is { Count: > 0 } ? [.. dto.RawTags] : [],
Probe = new ModbusProbeOptions
{
Enabled = dto.Probe?.Enabled ?? true,
Interval = TimeSpan.FromMilliseconds(dto.Probe?.IntervalMs ?? 5_000),
Timeout = TimeSpan.FromMilliseconds(dto.Probe?.TimeoutMs ?? 2_000),
ProbeAddress = dto.Probe?.ProbeAddress ?? 0,
},
KeepAlive = dto.KeepAlive is null ? new ModbusKeepAliveOptions() : new ModbusKeepAliveOptions
{
Enabled = dto.KeepAlive.Enabled ?? true,
Time = TimeSpan.FromMilliseconds(dto.KeepAlive.TimeMs ?? 30_000),
Interval = TimeSpan.FromMilliseconds(dto.KeepAlive.IntervalMs ?? 10_000),
RetryCount = dto.KeepAlive.RetryCount ?? 3,
},
IdleDisconnectTimeout = dto.IdleDisconnectMs is { } ms ? TimeSpan.FromMilliseconds(ms) : null,
Reconnect = dto.Reconnect is null ? new ModbusReconnectOptions() : new ModbusReconnectOptions
{
InitialDelay = TimeSpan.FromMilliseconds(dto.Reconnect.InitialDelayMs ?? 0),
MaxDelay = TimeSpan.FromMilliseconds(dto.Reconnect.MaxDelayMs ?? 30_000),
BackoffMultiplier = dto.Reconnect.BackoffMultiplier ?? 2.0,
},
};
return new ModbusDriver(
options, driverInstanceId,
transportFactory: null,
logger: loggerFactory?.CreateLogger<ModbusDriver>());
}
private static T ParseEnum<T>(string? raw, string? tagName, string driverInstanceId, string field) where T : struct, Enum
{
if (string.IsNullOrWhiteSpace(raw))
throw new InvalidOperationException(
$"Modbus tag '{tagName ?? "<unnamed>"}' in '{driverInstanceId}' missing {field}");
return Enum.TryParse<T>(raw, ignoreCase: true, out var v)
? v
: throw new InvalidOperationException(
$"Modbus tag '{tagName}' has unknown {field} '{raw}'. " +
$"Expected one of {string.Join(", ", Enum.GetNames<T>())}");
}
private static readonly JsonSerializerOptions JsonOptions = new()
{
PropertyNameCaseInsensitive = true,
ReadCommentHandling = JsonCommentHandling.Skip,
AllowTrailingCommas = true,
};
internal sealed class ModbusDriverConfigDto
{
/// <summary>Gets or sets the host address.</summary>
public string? Host { get; init; }
/// <summary>Gets or sets the port number.</summary>
public int? Port { get; init; }
/// <summary>Gets or sets the unit identifier.</summary>
public byte? UnitId { get; init; }
/// <summary>Gets or sets the timeout in milliseconds.</summary>
public int? TimeoutMs { get; init; }
/// <summary>Gets or sets the maximum number of registers per read operation.</summary>
public ushort? MaxRegistersPerRead { get; init; }
/// <summary>Gets or sets the maximum number of registers per write operation.</summary>
public ushort? MaxRegistersPerWrite { get; init; }
/// <summary>Gets or sets the maximum number of coils per read operation.</summary>
public ushort? MaxCoilsPerRead { get; init; }
/// <summary>Gets or sets a value indicating whether to use function code 15 for single coil writes.</summary>
public bool? UseFC15ForSingleCoilWrites { get; init; }
/// <summary>Gets or sets a value indicating whether to use function code 16 for single register writes.</summary>
public bool? UseFC16ForSingleRegisterWrites { get; init; }
/// <summary>Gets or sets a value indicating whether to disable function code 23.</summary>
public bool? DisableFC23 { get; init; }
/// <summary>Gets or sets a value indicating whether to write only on change.</summary>
public bool? WriteOnChangeOnly { get; init; }
/// <summary>Gets or sets the maximum gap between register addresses for coalescing.</summary>
public ushort? MaxReadGap { get; init; }
/// <summary>Gets or sets the Modbus family type.</summary>
public string? Family { get; init; }
/// <summary>Gets or sets the Melsec subfamily.</summary>
public string? MelsecSubFamily { get; init; }
/// <summary>Gets or sets the automatic prohibition reprobei interval in milliseconds.</summary>
public int? AutoProhibitReprobeMs { get; init; }
/// <summary>Gets or sets a value indicating whether automatic reconnection is enabled.</summary>
public bool? AutoReconnect { get; init; }
/// <summary>Gets or sets the authored raw tags (RawPath + TagConfig blob + WriteIdempotent) the
/// deploy artifact delivers. The driver maps each through the tag-definition factory at Initialize.</summary>
public List<RawTagEntry>? RawTags { get; init; }
/// <summary>Gets or sets the probe configuration.</summary>
public ModbusProbeDto? Probe { get; init; }
/// <summary>Gets or sets the keep-alive configuration (connection-layer knob).</summary>
public ModbusKeepAliveDto? KeepAlive { get; init; }
/// <summary>Gets or sets the idle disconnect timeout in milliseconds.</summary>
public int? IdleDisconnectMs { get; init; }
/// <summary>Gets or sets the reconnect configuration.</summary>
public ModbusReconnectDto? Reconnect { get; init; }
}
internal sealed class ModbusKeepAliveDto
{
/// <summary>Gets or sets a value indicating whether keep-alive is enabled.</summary>
public bool? Enabled { get; init; }
/// <summary>Gets or sets the keep-alive time in milliseconds.</summary>
public int? TimeMs { get; init; }
/// <summary>Gets or sets the keep-alive interval in milliseconds.</summary>
public int? IntervalMs { get; init; }
/// <summary>Gets or sets the retry count.</summary>
public int? RetryCount { get; init; }
}
internal sealed class ModbusReconnectDto
{
/// <summary>Gets or sets the initial reconnect delay in milliseconds.</summary>
public int? InitialDelayMs { get; init; }
/// <summary>Gets or sets the maximum reconnect delay in milliseconds.</summary>
public int? MaxDelayMs { get; init; }
/// <summary>Gets or sets the backoff multiplier for exponential reconnect delays.</summary>
public double? BackoffMultiplier { get; init; }
}
internal sealed class ModbusProbeDto
{
/// <summary>Gets or sets a value indicating whether probing is enabled.</summary>
public bool? Enabled { get; init; }
/// <summary>Gets or sets the probe interval in milliseconds.</summary>
public int? IntervalMs { get; init; }
/// <summary>Gets or sets the probe timeout in milliseconds.</summary>
public int? TimeoutMs { get; init; }
/// <summary>Gets or sets the probe register address.</summary>
public ushort? ProbeAddress { get; init; }
}
}