- deferment.md: node ACLs no longer authored-but-inert (#520 shipped through stage 7, opt-in Security:Acl:Enabled); failure-visibility trio mostly closed (01/S-1 + 03/S4 fixed, 06/S-1 partial); bulkhead + WriteIdempotentAttribute closed by R2-02; Sql Postgres+Oracle dialects shipped (d54f3c83); akka-hosting partials verified superseded - archreview/00-OVERALL.md: staleness banner on the carried-open block (04/C-1→R2-05, 03/S2+S3→R2-08, 03/P1→R2-07, driver fleet→R2-09/R2-11/#457, hygiene→R2-12, trio per above; what genuinely remains from theme 4) - archreview/plans/STATUS.md: carved out the true exceptions to "every Round-2 live gate GREEN" (R2-03 T11/T12 deferred-live, R2-10 T10 breaker-OPEN never forced); #459 closed by mesh Phase 7 drill D4 (c50ebcf7) - archreview/plans/INTEGRATION-SWEEP-STATUS.md: "follow-ups unstarted" → all 7 shipped as PRs #446–#452 - archreview/06-gateway-integrations.md: 06/S-1 STILL OPEN → PARTIAL (fail-closed advise + unconfirmed meter; residual cross-repo) - 2026-07-31-apikey-acl-enforcement-design.md: status → implemented through stage 7, #520 CLOSED 2026-08-01 - 2026-07-21-per-cluster-mesh-design.md: "Phases 1–7 not started" → PROGRAM COMPLETE 2026-07-24 (Phase 7c50ebcf7) - 2026-07-20-localdb-phase2-live-gate.md: merged as 06b5d81b; open design question shipped by mesh Phase 6 (checks 3/4 still never re-run on the three-mesh topology) - 2026-07-20-localdb-phase1-progress.md: Tasks 10–16 REMAIN → Phase 1 complete, live-gated 8/8, mergedc957db52- 2026-08-06-clusterclient-to-grpc-tracking.md: defect 4 OPEN → fixed byc0475f2d+e54883a8, merged @b360239e- 2026-08-06-clusterclient-to-grpc.md.tasks.json: Task 15 pending → completed (Phase 4 gate PASS 8/8 @0b194003, recordd0ac6fc5) - 2026-07-22-mesh-phase2-live-gate.md: DriverStatusPanel orphan → wired into /hosts by #546 (9420f8ef) - 2026-07-21-issue-485-live-gate.md: pointer from the "NOT fixed here" finding to the #486 fix (DriverHostActor.cs:1696-1717 + FetchAndCache mirror) - 2026-08-05-sql-postgres-oracle.md: chrome/AdminUI gate not deferred — PASSED 2026-08-05, found + fixed the Test-Connect provider gate (4e461951) - v2-ga-lab-gates-plan.md / v2-release-readiness.md / live-hardware-validation-runbooks.md: FOCAS live-CNC smoke #54 RESOLVED on a real 31i-B 2026-06-25 (cnc_rdparam caveat preserved) - Mqtt-Test-Fixture.md: STATE/DCMD "not implemented" → shipped + live-gated (#5082a7d1167, #511857a10b4) - 2026-08-01-continuous-historization-live-gate.md: poison-tag FIFO pin "filed, not fixed" → #538 fixed same day (e7fbe977, gate 4bdce910; Capacity default now 500k) - 2026-05-26-akka-hosting-alignment-plan.md.tasks.json: F8/F9/F10/F13/F14 partial → completed, superseded by the v3 address-space rework (Phase7Composer/ScriptedAlarmActor deleted; evaluators/SDK sinks/security policies production-wired) Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
11 KiB
v2 GA Lab Gates Plan
Canonical tracker:
docs/v2/v2-release-readiness.md— all code-path release blockers are closed as of 2026-04-24. This document maps the remaining exit-criteria from that tracker to concrete commands, automation boundaries, operator procedures, and pass criteria.Status: RELEASE-READY (code-path). Manual/lab gates remain open.
The gate list
From docs/v2/v2-release-readiness.md §"Release-readiness exit criteria":
| # | Gate | Kind | Automatable here |
|---|---|---|---|
| G1 | All four Phase 6.N compliance scripts exit 0 | Script | Yes — run on this box |
| G2 | dotnet test ZB.MOM.WW.OtOpcUa.slnx passes with <= 1 known-flake failure |
Script | Yes — run on this box |
| G3 | Release blockers closed | Audit | Already closed (code-path) |
| G4 | Phase 5 driver complement shipped | Audit | Already closed |
| G5 | Production deployment checklist signed off by Fleet Admin | Operator | No — separate doc, human signoff |
| G6 | At least one end-to-end integration run against live Galaxy succeeds | Dev rig | No — requires AVEVA platform |
| G7 | FOCAS live-CNC wire-level smoke (#54) passes against a real FANUC control | Lab hardware | ✅ RESOLVED 2026-06-25 (truth-sweep note 2026-08-07) — live-validated on a real 31i-B (10.201.31.5): version gate, timer, PMC range, servo-meter, alarms, probe all verified live; caveat: cnc_rdparam found unsupported on that control. See 2026-06-25-focas-pdu-v3-30i-b-support.md |
| G8 | OPC UA CTT / UA Compliance Test Tool passes against the live endpoint | Operator tool | No — requires CTT binary + live endpoint |
| G9 | Non-transparent redundancy cutover validated with >= 1 production client | Lab | No — see docs/plans/phase-6-3-redundancy-interop-plan.md |
G1 — Phase 6 compliance scripts
Command
pwsh ./scripts/compliance/phase-6-all.ps1
This meta-runner at scripts/compliance/phase-6-all.ps1 invokes each
sub-script in a separate powershell.exe process to isolate exit codes:
| Sub-script | Phase | What it checks |
|---|---|---|
phase-6-1-compliance.ps1 |
6.1 Resilience & Observability | Polly resilience classes, health endpoints, LiteDB sealed cache, observability sinks |
phase-6-2-compliance.ps1 |
6.2 Authorization runtime | AuthorizationGate, TriePermissionEvaluator, NodeScopeResolver, dispatch wiring in DriverNodeManager |
phase-6-3-compliance.ps1 |
6.3 Redundancy runtime | ServiceLevelCalculator 8-state band values, RecoveryStateManager, ApplyLeaseRegistry, ServerRedundancyNodeWriter; also invokes dotnet test with a baseline of 1097 |
phase-6-4-compliance.ps1 |
6.4 Admin UI completion | Data-layer types, Identification folder, deferred Blazor items marked [DEFERRED] |
Pass criterion
Phase 6 aggregate: PASS
Exit code 0. Any [FAIL] line is a blocker. [DEFERRED] lines are expected
for the known-deferred surfaces listed in the implementation docs; they do not
fail the run.
Prerequisites
- SQL Server
10.100.0.35,14330reachable (Config DB tests use it). dotnetSDK on PATH (.NET 10).- Run from repo root.
G2 — Full solution test suite
Command
dotnet test ZB.MOM.WW.OtOpcUa.slnx --logger "console;verbosity=minimal"
For a more targeted run of integration suites that need their fixtures up:
# bring modbus fixture up first
lmxopcua-fix up modbus standard
dotnet test ZB.MOM.WW.OtOpcUa.slnx --logger "console;verbosity=minimal"
Pass criterion
- Passed count >= 1159 (2026-04-19 baseline after Phase 5 driver complement).
- Failed count <= 1 (the pre-existing
SubscribeCommandTests.Execute_PrintsSubscriptionMessageflake inClient.CLIis the only tolerated failure). - No new
[FAILED]tests relative to the baseline.
Known flake
ZB.MOM.WW.OtOpcUa.Client.CLI.Tests::SubscribeCommandTests.Execute_PrintsSubscriptionMessage
is a timing-sensitive subscribe-then-cancel test. Rerun the specific project
if it appears:
dotnet test tests/Client/ZB.MOM.WW.OtOpcUa.Client.CLI.Tests `
--filter "FullyQualifiedName~SubscribeCommandTests.Execute_PrintsSubscriptionMessage" `
--count 3
If it fails all three runs, investigate; otherwise treat as flake.
Docker fixtures needed for integration suites
| Driver | Command | Endpoint used |
|---|---|---|
| Modbus | lmxopcua-fix up modbus standard |
10.100.0.35:5020 |
| AB CIP | lmxopcua-fix up abcip controllogix |
10.100.0.35:44818 |
| S7 | lmxopcua-fix up s7 s7_1500 |
10.100.0.35:1102 |
| OPC UA Client | lmxopcua-fix up opcuaclient |
opc.tcp://10.100.0.35:50000 |
| FOCAS | lmxopcua-fix up focas (mock server) |
10.100.0.35:8193 |
TwinCAT integration tests require the TCBSD ESXi VM at 10.100.0.128
(AmsNetId 41.169.163.43.1.1). Set env var before running:
$env:TWINCAT_TARGET_HOST = "10.100.0.128"
$env:TWINCAT_TARGET_NETID = "41.169.163.43.1.1"
dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.IntegrationTests
Galaxy integration tests run against the live mxaccessgw on the dev box (gate G6).
G3 — Release blockers closed (audit, already satisfied)
All three code-path release blockers are closed per v2-release-readiness.md:
- Authorization dispatch wiring (task #143, PR #94) — CLOSED.
- Config fallback Phase 6.1 Stream D (task #136, PR #96) — CLOSED.
- Redundancy Phase 6.3 Streams A/C core (tasks #145/#147, PRs #98-99) — CLOSED.
No action required. Record the PR numbers in the release notes.
G4 — Driver complement (audit, already satisfied)
All eight drivers shipped:
Galaxy, Modbus (+ DL205/S7/MELSEC profiles), S7 native, OPC UA Client, AB CIP,
AB Legacy, TwinCAT ADS, FOCAS (managed wire client — Tier-C isolation retired,
FOCAS is now Tier A in-process via WireFocasClient).
No action required.
G5 — Production deployment checklist (operator action)
The deployment checklist is a separate document covering:
- Windows service install (
scripts/install/Install-Services.ps1) - Config DB migration (
scripts/db/Apply-Migrations.ps1) - Certificate provisioning and trust
- LDAP / GLAuth configuration for production AD target
- mxaccessgw API key provisioning (
apikey create-keyin the sibling repo) - Service account permissions
- Prometheus / OpenTelemetry export configuration
- Firewall rules (port 4840 OPC UA, port 5120 gRPC to mxaccessgw, Admin port 5000/5001)
Sign-off party: Fleet Admin (operator). Not automatable.
Record sign-off as a comment on the v2 release issue.
G6 — Live Galaxy end-to-end integration run
Requires: AVEVA System Platform installed on dev box (confirmed available
per project memory project_aveva_platform_installed.md); mxaccessgw running
with a provisioned API key; at least one Galaxy object deployed.
Procedure
-
Start mxaccessgw:
# in sibling repo C:\Users\dohertj2\Desktop\mxaccessgw\ dotnet run --project src/MxGateway.Server -- --apikey-path .local/api-key.txt -
Start OtOpcUa server with Galaxy driver instance configured:
sc start OtOpcUa -
Browse via Client CLI:
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- ` browse -u opc.tcp://localhost:4840 -r -d 3 -
Read a known Galaxy tag (e.g. a deployed
$UserDefinedobject attribute):dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- ` read -u opc.tcp://localhost:4840 -n "ns=2;s=<tag_name.AttributeName>" -
Subscribe and verify live updates:
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- ` subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=<tag_name.AttributeName>" -i 1000
Pass criterion
- Browse returns a non-empty node tree mirroring the Galaxy hierarchy.
- Read returns
Goodquality with a non-null value. - Subscribe receives at least one data-change notification within 5 s (or within the configured publishing interval).
- No
BadNoCommunicationorBadTimeouterrors in the server log.
Record: Galaxy version, deployed object count, OtOpcUa git SHA.
G7 — FOCAS live-CNC smoke (task #54)
Requires: real FANUC CNC with Ethernet option, accessible on TCP port 8193 from the dev box; CNC series known (e.g. 0i-F, 30i-B).
See docs/plans/live-hardware-validation-runbooks.md §FOCAS for the full
runbook.
Pass criterion
WireFocasClientopens a FOCAS2 session (cnc_allclibhndl3succeeds).- Identity nodes (
Identity/SeriesNumber,Identity/MaxAxes) return non-null values matching the physical control panel display. - At least one axis position (
Axes/X/AbsolutePositionor similar) returnsGoodquality with a plausible double value. - Subscribe on a polled tag delivers at least three updates within 5 s.
- No
EW_SOCKET(-1) orEW_HANDLE(-7) errors in the server log during a 2-minute soak.
Record: CNC series, firmware version, test date, OtOpcUa git SHA.
G8 — OPC UA Conformance Test Tool (CTT) pass
Requires: OPC Foundation OPC UA Compliance Test Tool (CTT) or the open-source UA Compliance Test Tool installed on the client machine; live OtOpcUa server endpoint.
Recommended minimum profile set
Attribute ReadAttribute WriteBrowseSubscription(DataChange)Server-side monitoringSecurity — None profile(if server configured withSecurity:Profiles=[None])
Procedure
- Launch CTT. Add server endpoint:
opc.tcp://localhost:4840. - Run the profile set above.
- Capture the CTT report HTML/XML.
Pass criterion
All mandatory test cases in each profile: PASS or NOT APPLICABLE.
Zero mandatory failures. Advisory failures may be documented with rationale (e.g. optional capability not implemented).
Record: CTT version, profile set, OtOpcUa git SHA, report artifact.
G9 — Non-transparent redundancy cutover with production client
See docs/plans/phase-6-3-redundancy-interop-plan.md for the full runbook.
Minimum acceptable result: one complete pass of the A-block (UaExpert OPC UA signal verification) plus scenario B2 (UaExpert failover on Primary kill).
Ignition 8.3 is the recommended production client per decision #85. If Ignition is not available on the lab machine, UaExpert is accepted for v2 GA.
Record: client name + version, OtOpcUa git SHA, test date.
Gate summary table
| Gate | Command / Procedure | Pass criterion | Owner |
|---|---|---|---|
| G1 | pwsh ./scripts/compliance/phase-6-all.ps1 |
Exit 0, no [FAIL] |
Dev |
| G2 | dotnet test ZB.MOM.WW.OtOpcUa.slnx |
>= 1159 passing, <= 1 failure | Dev |
| G3 | Audit PR list in release-readiness.md | All blockers show CLOSED | Dev |
| G4 | Audit driver table | All 8 drivers listed as shipped | Dev |
| G5 | Run deployment checklist doc | All items checked; Fleet Admin signs off | Fleet Admin |
| G6 | Browse/read/subscribe against live Galaxy | Good quality, non-empty tree | Dev (dev box) |
| G7 | FOCAS CNC smoke — see live-hardware runbook | Session open, Good quality reads | Dev + lab hardware |
| G8 | CTT profile run against live endpoint | Zero mandatory failures | Dev + CTT tool |
| G9 | Redundancy cutover runbook | A-block + B2 pass with >= 1 client | Dev + two instances |