Files
lmxopcua/_p54.json
Joseph Doherty 10c724b5b6 Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
2026-04-18 22:57:03 -04:00

2 lines
1.5 KiB
JSON

{"title":"Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research doc","body":"## Summary\n\nAdds `docs/v2/s7.md` (485 lines) covering Siemens SIMATIC S7 family Modbus TCP behavior. Mirrors the `docs/v2/dl205.md` template for future per-quirk implementation PRs.\n\n## Key findings for the implementation track\n\n- **No fixed memory map** — every S7 Modbus server is user-wired via `MB_SERVER`/`MODBUSCP`/`MODBUSPN` library blocks. Driver must accept per-site config, not assume a vendor layout.\n- **MB_SERVER requires non-optimized DBs** (STATUS `0x8383` if optimized). Most common field bug.\n- **Word order default = ABCD** (opposite of DL260). Driver's S7 profile default must be `ByteOrder.BigEndian`, not `WordSwap`.\n- **One port per MB_SERVER instance** — multi-client requires parallel FBs on 503/504/… Most clients assume port 502 multiplexes (wrong on S7).\n- **CP 343-1 Lean is server-only**, requires the `2XV9450-1MB00` license.\n- **FC20/21/22/23/43 all return Illegal Function** on every S7 variant — driver must not attempt FC23 bulk-read optimization for S7.\n- **STOP-mode behavior non-deterministic** across firmware bands — treat both read/write STOP-mode responses as unavailable.\n\nTwo items flagged as unconfirmed rumour (V2.0+ float byte-order claim, STOP-mode caching location).\n\nNo code, no tests — implementation lands in PRs 56+.\n\n## Test plan\n- [x] Doc renders as markdown\n- [x] 31 citations present\n- [x] Section structure matches dl205.md template","head":"phase-3-pr54-s7-research-doc","base":"v2"}