Files
lmxopcua/tests
Joseph Doherty 854c3bcfec Phase 6.1 Stream D — LiteDB generation-sealed config cache + ResilientConfigReader + UsingStaleConfig flag
Closes Stream D per docs/v2/implementation/phase-6-1-resilience-and-observability.md.

New Configuration.LocalCache types (alongside the existing single-file
LiteDbConfigCache):

- GenerationSealedCache — file-per-generation sealed snapshots per decision
  #148. Each SealAsync writes <cache-root>/<clusterId>/<generationId>.db as a
  read-only LiteDB file, then atomically publishes the CURRENT pointer via
  temp-file + File.Replace. Prior-generation files stay on disk for audit.
  Mixed-generation reads are structurally impossible: ReadCurrentAsync opens
  the single file named by CURRENT. Corruption of the pointer or the sealed
  file raises GenerationCacheUnavailableException — fails closed, never falls
  back silently to an older generation. TryGetCurrentGenerationId returns the
  pointer value or null for diagnostics.

- StaleConfigFlag — thread-safe (Volatile.Read/Write) bool. MarkStale when a
  read fell back to the cache; MarkFresh when a central-DB read succeeded.
  Surfaced on /healthz body and Admin /hosts (Stream C wiring already in
  place).

- ResilientConfigReader — wraps a central-DB fetch function with the Stream
  D.2 pipeline: timeout 2 s → retry N× jittered (skipped when retryCount=0) →
  fallback to the sealed cache. Toggles StaleConfigFlag per outcome. Read path
  only — the write path is expected to bypass this wrapper and fail hard on
  DB outage so inconsistent writes never land. Cancellation passes through
  and is NOT retried.

Configuration.csproj:
- Polly.Core 8.6.6 + Microsoft.Extensions.Logging.Abstractions added.

Tests (17 new, all pass):
- GenerationSealedCacheTests (10): first-boot-no-snapshot throws
  GenerationCacheUnavailableException (D.4 scenario C), seal-then-read round
  trip, sealed file is ReadOnly on disk, pointer advances to latest, prior
  generation file preserved, corrupt sealed file fails closed, missing sealed
  file fails closed, corrupt pointer fails closed (D.4 scenario B), same
  generation sealed twice is idempotent, independent clusters don't
  interfere.
- ResilientConfigReaderTests (4): central-DB success returns value + marks
  fresh; central-DB failure exhausts retries + falls back to cache + marks
  stale (D.4 scenario A); central-DB + cache both unavailable throws;
  cancellation not retried.
- StaleConfigFlagTests (3): default is fresh; toggles; concurrent writes
  converge.

Full solution dotnet test: 1033 passing (baseline 906, +127 net across Phase
6.1 Streams A/B/C/D). Pre-existing Client.CLI Subscribe flake unchanged.

Integration into Configuration read paths (DriverInstance enumeration,
LdapGroupRoleMapping fetches, etc.) + the sp_PublishGeneration hook that
writes sealed files lands in the Phase 6.1 Stream E / Admin-refresh PR where
the DB integration surfaces are already touched. Existing LiteDbConfigCache
continues serving its single-file role for the NodeBootstrap path.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 08:33:32 -04:00
..
Phase 3 PR 28 — Admin UI cert-trust management page. New /certificates route (FleetAdmin-only) surfaces the OPC UA server's PKI store rejected + trusted certs and gives operators Trust / Delete / Revoke actions so rejected client certs can be promoted without touching disk. CertTrustService reads $PkiStoreRoot/{rejected,trusted}/certs/*.der files directly via X509CertificateLoader — no Opc.Ua dependency in the Admin project, which keeps the Admin host runnable on a machine that doesn't have the full Server install locally (only needs the shared PKI directory reachable; typical deployment has Admin + Server side-by-side on the same box and PkiStoreRoot defaults match so a plain-vanilla install needs no override). CertTrustOptions bound from the Admin's 'CertTrust:PkiStoreRoot' section, default %ProgramData%\OtOpcUa\pki (matches OpcUaServerOptions.PkiStoreRoot default). Trust action moves the .der from rejected/certs/ to trusted/certs/ via File.Move(overwrite:true) — idempotent, tolerates a concurrent operator doing the same move. Delete wipes the file. Revoke removes from trusted/certs/ (Opc.Ua re-reads the Directory store on each new client handshake, so no explicit reload signal is needed; operators retry the rejected connection after trusting). Thumbprint matching is case-insensitive because X509Certificate2.Thumbprint is upper-case hex but operators copy-paste from logs that sometimes lowercase it. Malformed files in the store are logged + skipped — a single bad .der can't take the whole management page offline. Missing store directories produce empty lists rather than exceptions so a pristine install (Server never run yet, no rejected/trusted dirs yet) doesn't crash the page.
2026-04-18 14:37:55 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
Phase 3 PR 76 -- OPC UA Client IHistoryProvider (HistoryRead passthrough). Driver now implements IHistoryProvider (Raw + Processed + AtTime); ReadEventsAsync deliberately inherits the interface default that throws NotSupportedException. ExecuteHistoryReadAsync is the shared wire path: parses the fullReference to NodeId, builds a HistoryReadValueIdCollection with one entry, calls Session.HistoryReadAsync(RequestHeader, ExtensionObject<details>, TimestampsToReturn.Both, releaseContinuationPoints:false, nodesToRead, ct), unwraps r.HistoryData ExtensionObject into the samples list, passes ContinuationPoint through. Each DataValue's upstream StatusCode + SourceTimestamp + ServerTimestamp preserved verbatim per driver-specs.md \u00A78 cascading-quality rule -- this matters especially for historical data where an interpolated / uncertain-quality sample must surface its true severity downstream, not a sanitized Good. SourceTimestamp=DateTime.MinValue guards map to null so downstream clients see 'source unknown' rather than an epoch-zero misread. ReadRawAsync builds ReadRawModifiedDetails with IsReadModified=false (raw, not modified-history), StartTime/EndTime, NumValuesPerNode=maxValuesPerNode, ReturnBounds=false (clients that want bounds request them via continuation handling). ReadProcessedAsync builds ReadProcessedDetails with ProcessingInterval in ms + AggregateType wrapping a single NodeId from MapAggregateToNodeId. MapAggregateToNodeId switches on HistoryAggregateType {Average, Minimum, Maximum, Total, Count} to the standard Part 13 ObjectIds.AggregateFunction_* NodeId -- future aggregate-type additions fail the switch with ArgumentOutOfRangeException so they can't silently slip through with a null NodeId and an opaque server-side BadAggregateNotSupported. ReadAtTimeAsync builds ReadAtTimeDetails with ReqTimes + UseSimpleBounds=true (returns boundary samples when an exact timestamp has no value -- the OPC UA Part 11 default). Malformed NodeId short-circuits to empty result without touching the wire, matching the ReadAsync / WriteAsync pattern. ReadEventsAsync stays at the interface-default NotSupportedException: the OPC UA call path (HistoryReadAsync with ReadEventDetails + EventFilter) needs an EventFilter SelectClauses spec which the current IHistoryProvider.ReadEventsAsync signature doesn't carry. Adding that would be an IHistoryProvider interface widening; out of scope for PR 76. Callers see BadHistoryOperationUnsupported on the OPC UA client which is the documented fallback. Name disambiguation: Core.Abstractions.HistoryReadResult and Opc.Ua.HistoryReadResult both exist; used fully-qualified Core.Abstractions.HistoryReadResult in return types + factory expressions. Shutdown unchanged -- history reads don't create persistent server-side resources, so no cleanup needed beyond the existing Session.CloseAsync. Unit tests (OpcUaClientHistoryTests, 7 facts): MapAggregateToNodeId theory covers all 5 aggregates; MapAggregateToNodeId_rejects_invalid_enum (defense against future enum addition silently passing through); Read{Raw,Processed,AtTime}Async_without_initialize_throws (RequireSession path); ReadEventsAsync_throws_NotSupportedException (locks in the intentional inheritance of the default). 78/78 OpcUaClient.Tests pass (67 prior + 11 new, -4 on the alarm suite moved into the events count). dotnet build clean. Final OPC UA Client capability surface: IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable + IHostConnectivityProbe + IAlarmSource + IHistoryProvider -- 8 of 8 possible capabilities. Driver is feature-complete per driver-specs.md \u00A78.
2026-04-19 02:13:22 -04:00