Joseph Doherty 02fccbc762 Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
Three substantive issues caught + fixed during the validation pass:
1. pymodbus rejects unknown keys at device-list / setup level. My PR 43 commit had `_layout_note`, `_uint16_layout`, `_bits_layout`, `_write_note` device-level JSON-comment fields that crashed pymodbus startup with `INVALID key in setup`. Removed all device-level _* fields. Inline `_quirk` keys WITHIN individual register entries are tolerated by pymodbus 3.13.0 — kept those in dl205.json since they document the byte math per quirk and the README + git history aren't enough context for a hand-author reading raw integer values. Documented the constraint in the top-level _comment of each profile.
2. pymodbus rejects sweeping `write` ranges that include any cell not assigned a type. My initial standard.json had `write: [[0, 2047]]` but only seeded HR[0..31] + HR[100] + HR[200..209] + bits[1024..1109] — pymodbus blew up on cell 32 (gap between HR[31] and HR[100]). Fixed by listing per-block write ranges that exactly mirror the seeded ranges. Same fix in dl205.json (was `[[0, 16383]]`).
3. pymodbus simulator stores all 4 standard Modbus tables in ONE underlying cell array — each cell can only be typed once (BITS or UINT16, not both). My initial standard.json had `bits[0..31]` AND `uint16[0..31]` overlapping at the same addresses; pymodbus crashed with `ERROR "uint16" <Cell> used`. Fixed by relocating coils to address 1024+, well clear of the uint16 entries at 0..209. Documented the layout constraint in the standard.json top-level _comment.
Substantive driver bug fixed: ModbusTcpTransport.ConnectAsync was using `new TcpClient()` (default constructor — dual-stack, IPv6 first) then `ConnectAsync(host, port)` with the user's hostname. .NET's TcpClient default-resolves "localhost" to ::1 first, fails to connect to pymodbus (which binds 0.0.0.0 IPv4-only), and only then retries IPv4 — the failure surfaces as the entire ConnectAsync timeout (2s by default) before the IPv4 attempt even starts. PR 30's smoke test silently SKIPPED because the fixture's TCP probe hit the same dual-stack ordering and timed out. Both fixed: ModbusSimulatorFixture probe now resolves Dns.GetHostAddresses, prefers AddressFamily.InterNetwork, dials IPv4 explicitly. ModbusTcpTransport does the same — resolves first, prefers IPv4, falls back to whatever Dns returns (handles IPv6-only hosts in the future). This is a real production-readiness fix because most Modbus PLCs are IPv4-only — a generic dual-stack TcpClient would burn the entire connect timeout against any IPv4-only PLC, masquerading as a connection failure when the PLC is actually fine.
Smoke-test address shifted HR[100] -> HR[200]. Standard.json's HR[100] is the auto-incrementing register that drives subscribe-and-receive tests, so write-then-read against it would race the increment. HR[200] is the first cell of a writable scratch range present in BOTH simulator profiles. DL205Profile.cs xml-doc updated to explain the shift; tag name "DL205_Smoke_HReg100" -> "Smoke_HReg200" + smoke test references updated. dl205.json gains a matching scratch HR[200..209] range so the smoke test runs identically against either profile.
Validation matrix:
- standard.json boot: clean (TCP 5020 listening within ~3s of pymodbus.simulator launch).
- dl205.json boot: clean.
- pymodbus client direct FC06 to HR[200]=1234 + FC03 read: round-trip OK.
- raw-bytes PowerShell TcpClient FC06 + 12-byte response: matches FC06 spec (echo of address + value).
- DL205SmokeTest against standard.json: 1/1 pass (was failing as 'BadInternalError' due to the dual-stack timeout + tag-name typo — both fixed).
- DL205SmokeTest against dl205.json: 1/1 pass.
- Modbus.Tests Unit suite: 52/52 pass — dual-stack transport fix is non-breaking.
- Solution build clean.
Memory + future-PR setup: pymodbus install + activation pattern is now bullet-pointed at the top of Pymodbus/README.md so future PRs (the per-quirk DL205_<behavior> tests in PR 44+) don't have to repeat the trial-and-error of getting the simulator + integration tests cooperating. The three bugs above are documented inline in the JSON profiles + ModbusTcpTransport so they don't bite again.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 21:14:02 -04:00
..
Phase 3 PR 34 — Host-status publisher (Server) + /hosts drill-down page (Admin). Closes LMX follow-up #7 by wiring together the data layer from PR 33. Server.HostStatusPublisher is a BackgroundService that walks every driver registered in DriverHost every 10 seconds, skips drivers that don't implement IHostConnectivityProbe, calls GetHostStatuses() on each probe-capable driver, and upserts one DriverHostStatus row per (NodeId, DriverInstanceId, HostName) into the central config DB. Upsert path: SingleOrDefaultAsync on the composite PK; if no row exists, Add a new one; if a row exists, LastSeenUtc advances unconditionally (heartbeat) and State + StateChangedUtc update only on transitions so Admin UI can distinguish 'still reporting, still Running' from 'freshly transitioned to Running'. MapState translates Core.Abstractions.HostState to Configuration.Enums.DriverHostState (intentional duplicate enum — Configuration project stays free of driver-runtime deps per PR 33's choice). If a driver's GetHostStatuses throws, log warning and skip that driver this tick — never take down the Server on a publisher failure. If the DB is unreachable, log warning + retry next heartbeat (no buffering — next tick's current-state snapshot is more useful than replaying stale transitions after a long outage). 2-second startup delay so NodeBootstrap's RegisterAsync calls land before the first publish tick, then tick runs immediately so a freshly-started Server surfaces its host topology in the Admin UI without waiting a full interval.
2026-04-18 15:51:55 -04:00
Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
2026-04-18 08:00:36 -04:00
Phase 2 PR 14 — alarm subsystem wire-up. Per IsAlarm=true attribute (PR 9 added the discovery flag), GalaxyAlarmTracker in Backend/Alarms/ advises the four Galaxy alarm-state attributes: .InAlarm (boolean alarm active), .Priority (int severity), .DescAttrName (human-readable description), .Acked (boolean acknowledged). Runs the OPC UA Part 9 alarm lifecycle state machine simplified for the Galaxy AlarmExtension model and raises AlarmTransition events on transitions operators must react to — Active (InAlarm false→true, default Unacknowledged), Acknowledged (Acked false→true while InAlarm still true), Inactive (InAlarm true→false). MxAccessGalaxyBackend instantiates the tracker in its constructor with delegate-based subscribe/unsubscribe/write pointers to MxAccessClient, hooks TransitionRaised to forward each transition through the existing OnAlarmEvent IPC event that PR 4 ConnectionSink wires into MessageKind.AlarmEvent frames — no new contract messages required since GalaxyAlarmEvent already exists in Shared.Contracts. Field mapping: EventId = fresh Guid.ToString('N') per transition, ObjectTagName = alarm attribute full reference, AlarmName = alarm attribute full reference, Severity = tracked Priority, StateTransition = 'Active'|'Acknowledged'|'Inactive', Message = DescAttrName or tag fallback, UtcUnixMs = transition time. DiscoverAsync caches every IsAlarm=true attribute's full reference (tag.attribute) into _discoveredAlarmTags (ConcurrentBag cleared-then-filled on every re-Discover to track Galaxy redeploys). SubscribeAlarmsAsync iterates the cache and advises each via GalaxyAlarmTracker.TrackAsync; best-effort per-alarm — a subscribe failure on one alarm doesn't abort the whole call since operators prefer partial alarm coverage to none. Tracker is internally idempotent on repeat Track calls (second invocation for same alarm tag is a no-op; already-subscribed check short-circuits before the 4 MXAccess sub calls). Subscribe-failure rollback inside TrackAsync removes the alarm state + unadvises any of the 4 that did succeed so a partial advise can't leak a phantom tracking entry. AcknowledgeAlarmAsync routes to tracker.AcknowledgeAsync which writes the operator comment to <tag>.AckMsg via MxAccessClient.WriteAsync — writes use the existing MXAccess OnWriteComplete TCS-by-handle path (PR 4 Medium 4) so a runtime-refused ack bubbles up as Success=false rather than false-positive. State-machine quirks preserved from v1: (1) initial Acked=true on subscribe does NOT fire Acknowledged (alarm at rest, pre-acknowledged — default state is Acked=true so the first subscribe callback is a no-op transition), (2) Acked false→true only fires Acknowledged when InAlarm is currently true (acking a latched-inactive alarm is not a user-visible transition), (3) Active transition clears the Acked flag in-state so the next Acked callback correctly fires Acknowledged (v1 had this buried in the ConditionState logic; we track it on the AlarmState struct directly). Priority value handled as int/short/long via type pattern match with int.MaxValue guard — Galaxy attribute category returns varying CLR types (Int32 is canonical but some older templates use Int16), and a long overflow cast to int would silently corrupt the severity. Dispose cascade in MxAccessGalaxyBackend.Dispose: alarm-tracker unsubscribe→dispose, probe-manager unsubscribe→dispose, mx.ConnectionStateChanged detach, historian dispose — same discipline PR 6 / PR 8 / PR 13 established so dangling invocation-list refs don't survive a backend recycle. #pragma warning disable CS0067 around OnAlarmEvent removed since the event is now raised. Tests (9 new, GalaxyAlarmTrackerTests): four-attribute subscribe per alarm, idempotent repeat-track, InAlarm false→true fires Active with Priority + Desc, InAlarm true→false fires Inactive, Acked false→true while InAlarm fires Acknowledged, Acked transition while InAlarm=false does not fire, AckMsg write path carries the comment, snapshot reports latest four fields, foreign probe callback for a non-tracked tag is silently dropped. Full Galaxy.Host.Tests Unit suite 84 pass / 0 fail (9 new alarm + 12 PR 13 probe + 21 PR 12 quality + 42 pre-existing). Galaxy.Host builds clean (0/0). Branches off phase-2-pr13-runtime-probe so the MxAccessGalaxyBackend constructor/Dispose chain gets the probe-manager + alarm-tracker wire-up in a coherent order; fast-forwards if PR 13 merges first.
2026-04-18 07:34:13 -04:00
Phase 2 PR 11 — HistoryReadEvents IPC (alarm history). New Shared.Contracts messages HistoryReadEventsRequest/Response + GalaxyHistoricalEvent DTO (MessageKind 0x66/0x67). IGalaxyBackend gains HistoryReadEventsAsync, Stub/DbBacked return canonical pending error, MxAccessGalaxyBackend delegates to _historian.ReadEventsAsync (ported in PR 5) and maps HistorianEventDto → GalaxyHistoricalEvent — Guid.ToString() for EventId wire shape, DateTime → Unix ms for both EventTime (when the event fired in the process) and ReceivedTime (when the Historian persisted it), DisplayText + Severity pass through. SourceName is string? — null means 'all sources' (passed straight through to HistorianDataSource.ReadEventsAsync which adds the AddEventFilter('Source', Equal, ...) only when non-null). Distinct from the live GalaxyAlarmEvent type because historical rows carry both timestamps and lack StateTransition (Historian logs instantaneous events, not the OPC UA Part 9 alarm lifecycle; translating to OPC UA event lifecycle is the alarm-subsystem's job). Guards: null historian → Historian-disabled error; SDK exception → Success=false with message chained. Tests (3 new): disabled-error when historian null, maps HistorianEventDto with full field set (Id/Source/EventTime/ReceivedTime/DisplayText/Severity=900) to GalaxyHistoricalEvent, null SourceName passes through unchanged (verifies the 'all sources' contract). Galaxy.Host.Tests Unit suite 34 pass / 0 fail. Galaxy.Host builds clean. Branches off phase-2-pr10-history-attime since both extend the MessageKind enum; fast-forwards if PR 10 merges first.
2026-04-18 07:08:16 -04:00