using System.Buffers.Binary;
using System.Text;
namespace ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests.Simulator;
/// How a simulated family answers the R_RI selectors the driver reads.
public enum SimSelectorBehaviour
{
/// Every read selector answers (the iTNC 530 shape, hardware-captured).
All,
///
/// The TNC 640 observation (pyLSV2 docs/protocol.rst "Differences between different control versions",
/// NC 340590 10 SP2): 27/28/51 and 30–34 refuse T_ER_UNKNOWN_TELE (22); 25/26 need DNC; 24 serves the
/// program without DNC but with block number 0.
///
TncObserved,
///
/// Core telemetry only (22–26). pyLSV2's own suite asserts overrides/axes/exec state on every control but gates
/// tool (51) and error messages (27/28) to iTNC (tests/test_read_info.py), and its protocol table marks them
/// "no" on CNCpilot — so 27/28/51 and the iTNC lifetime timers 30–34 are refused 22 here. A conservative
/// assumption, not an observation, for the families pyLSV2 records nothing about.
///
CoreOnly,
}
/// One simulated HEIDENHAIN control family.
/// Test display name.
/// The R_VR model field.
/// The R_VR NC software field.
/// The family the driver must classify it as.
/// Which R_RI selectors answer.
/// True to send the 5-field R_VR (model, NC, PLC, SPLC, options).
/// Where the profile's strings come from.
public sealed record ControlProfile(
string Name, string Model, string Nc, HeidenhainControlFamily Family, SimSelectorBehaviour Selectors,
bool FiveFieldVersion, string Source)
{
public override string ToString() => Name;
}
///
/// Per-family simulator profiles. Model/NC strings come from the pyLSV2 (MIT) README "Programming Stations" and
/// "Machines" tables and dat_cls.py:VersionInfo; the iTNC 530 one from our own hardware record
/// (docs/drivers/evidence/heidenhain-live-2026-11-11.md). The R_VR field count follows pyLSV2 (MIT)
/// client.py:_read_version, which accepts exactly 4 or 5 NUL-separated fields on every family — which family
/// sends which shape is not recorded, so the 5-field variant is exercised on more than one family.
///
public static class ControlProfiles
{
public static readonly ControlProfile ITnc530 = new("iTNC 530", "iTNC530", "340490 04 SP10",
HeidenhainControlFamily.ITnc530, SimSelectorBehaviour.All, false, "hardware: Hermle59 2026-11-11");
public static readonly ControlProfile ITnc530Spaced = new("iTNC 530 (spaced)", "iTNC 530", "606420 03 SP4",
HeidenhainControlFamily.ITnc530, SimSelectorBehaviour.All, true, "pyLSV2 dat_cls.py strips spaces before classifying");
public static readonly ControlProfile Tnc640 = new("TNC 640", "TNC640", "340590 10 SP2",
HeidenhainControlFamily.Tnc, SimSelectorBehaviour.TncObserved, false, "pyLSV2 docs/protocol.rst + README");
public static readonly ControlProfile Tnc620 = new("TNC 620", "TNC620", "817605 04 SP1",
HeidenhainControlFamily.Tnc, SimSelectorBehaviour.TncObserved, true, "pyLSV2 README Machines");
public static readonly ControlProfile Tnc320 = new("TNC 320", "TNC320", "340554 04 SP1",
HeidenhainControlFamily.Tnc, SimSelectorBehaviour.TncObserved, false, "pyLSV2 README Programming Stations");
public static readonly ControlProfile Tnc128 = new("TNC 128", "TNC 128", "771841 01",
HeidenhainControlFamily.Tnc, SimSelectorBehaviour.TncObserved, false, "pyLSV2 dat_cls.py prefix only (NC string illustrative)");
public static readonly ControlProfile Tnc7 = new("TNC7", "TNC7", "817625 17",
HeidenhainControlFamily.Tnc7, SimSelectorBehaviour.CoreOnly, true, "pyLSV2 README Programming Stations");
public static readonly ControlProfile CncPilot640 = new("CNC PILOT 640", "CNCpilot640", "1230521 03 SP1",
HeidenhainControlFamily.Lathe, SimSelectorBehaviour.CoreOnly, false, "pyLSV2 README Programming Stations");
public static readonly ControlProfile ManualPlus620 = new("MANUALplus 620", "MANUALplus620", "634130 02 SP7",
HeidenhainControlFamily.Lathe, SimSelectorBehaviour.CoreOnly, false, "pyLSV2 README Programming Stations");
public static readonly ControlProfile MillPlus = new("MillPlus IT V600", "MillPlusIT V600", "538956 03 SP15",
HeidenhainControlFamily.MillPlus, SimSelectorBehaviour.CoreOnly, false, "pyLSV2 README Programming Stations");
public static readonly ControlProfile Tnc430 = new("TNC 430 (legacy)", "TNC 430", "280476 21",
HeidenhainControlFamily.LegacyTnc, SimSelectorBehaviour.CoreOnly, false, "no pyLSV2 rule (it reports UNKNOWN); illustrative");
public static readonly ControlProfile Unrecognised = new("Unrecognised", "Anilam 6000i", "000000 00",
HeidenhainControlFamily.Unknown, SimSelectorBehaviour.CoreOnly, false, "pyLSV2 ControlType.UNKNOWN");
public static IReadOnlyList All { get; } =
[ITnc530, ITnc530Spaced, Tnc640, Tnc620, Tnc320, Tnc128, Tnc7, CncPilot640, ManualPlus620, MillPlus, Tnc430, Unrecognised];
/// The R_VR reply for a profile.
public static byte[] VersionReply(ControlProfile p) => Encoding.Latin1.GetBytes(p.FiveFieldVersion
? $"{p.Model}\0{p.Nc}\0PLC1\0SPLC1\0%0000111100000111\0"
: $"{p.Model}\0{p.Nc}\0PLC1\0%0000111100000111\0");
/// A simulated control speaking the profile. DataPaths["/x"] is populated for every family, so a gate — not the simulator — is what keeps non-iTNC DATA off the wire.
public static SimulatedControl Build(ControlProfile p)
{
var dnc = 0;
var c = new SimulatedControl
{
Version = VersionReply(p),
Login = (role, _) =>
{
if (role == "DNC") Interlocked.Exchange(ref dnc, 1);
return SimReply.Ok("T_OK", []);
},
};
bool Dnc() => Volatile.Read(ref dnc) == 1;
c.Runtime[22] = () => SimReply.Ok("S_RI", [0, 2, .. Encoding.ASCII.GetBytes("1.5\0-2.25\0X\0Z\0")]);
c.Runtime[23] = () => SimulatedControl.U16(4);
c.DataPaths["/x"] = SimReply.Ok("S_DP", [0, 0, 0, 3, 0, 0, 0, 42]);
switch (p.Selectors)
{
case SimSelectorBehaviour.TncObserved:
c.Runtime[24] = () => SimReply.Ok("S_RI", Program(Dnc() ? 5 : 0));
c.Runtime[25] = () => Dnc() ? SimReply.Ok("S_RI", Overrides()) : SimReply.Refuse(23);
c.Runtime[26] = () => Dnc() ? SimulatedControl.U16(7) : SimReply.Refuse(23);
foreach (var s in new[] { 27, 28, 51, 30, 31, 32, 33, 34 }) c.Runtime[s] = () => SimReply.Refuse(22);
break;
case SimSelectorBehaviour.CoreOnly:
c.Runtime[24] = () => SimReply.Ok("S_RI", Program(5));
c.Runtime[25] = () => SimReply.Ok("S_RI", Overrides());
c.Runtime[26] = () => SimulatedControl.U16(7);
foreach (var s in new[] { 27, 28, 51, 30, 31, 32, 33, 34 }) c.Runtime[s] = () => SimReply.Refuse(22);
break;
default:
c.Runtime[24] = () => SimReply.Ok("S_RI", Program(5));
c.Runtime[25] = () => SimReply.Ok("S_RI", Overrides());
c.Runtime[26] = () => SimulatedControl.U16(7);
c.Runtime[27] = () => SimReply.Ok("S_RI", Alarm());
c.Runtime[28] = () => SimReply.Refuse(57);
c.Runtime[51] = () => SimReply.Ok("S_RI", new byte[24]);
for (var s = 30; s <= 34; s++) c.Runtime[s] = () => SimReply.Ok("S_RI", [0, 0, 1, 0]);
break;
}
return c;
}
private static byte[] Program(int line)
{
var b = new byte[4];
BinaryPrimitives.WriteUInt32BigEndian(b, (uint)line);
return [.. b, .. "TNC:\\nc_prog\\a.h\0TNC:\\nc_prog\\a.h\0"u8.ToArray()];
}
private static byte[] Overrides()
{
var b = new byte[12];
BinaryPrimitives.WriteUInt32BigEndian(b, 10000);
BinaryPrimitives.WriteUInt32BigEndian(b.AsSpan(4), 9000);
BinaryPrimitives.WriteUInt32BigEndian(b.AsSpan(8), 5000);
return b;
}