-- Modbus e2e smoke seed — v3 schema (Raw tree: DriverInstance → Device → Tag; UNS by reference). -- -- Idempotent — DELETE-and-recreate of one cluster's worth of Modbus test config: -- * 1 ServerCluster ('modbus-smoke') + ClusterNode ('modbus-smoke-node') + SqlLogin credential -- * 1 Modbus DriverInstance at the cluster root (RawFolderId NULL) -- * 1 Device carrying the pymodbus endpoint in DeviceConfig -- * 1 Tag at HR[200]:UInt16 under the device (HR[100] is auto-increment in standard.json, -- unusable as a write target — the e2e script uses HR[200] for that reason) -- * 1 UnsArea/UnsLine/Equipment + a UnsTagReference projecting the raw tag into UNS -- -- v3 changes vs. the pre-v2 original: the ConfigGeneration/GenerationId/Namespace model and the -- sp_PublishGeneration publish step are gone (deploy is a C# ControlPlane operation now); the -- connection endpoint moved from DriverConfig into the Device's DeviceConfig. -- -- Usage: -- sqlcmd -S "10.100.0.35,14330" -d -U sa -P "" -i scripts/smoke/seed-modbus-smoke.sql SET NOCOUNT ON; SET XACT_ABORT ON; SET QUOTED_IDENTIFIER ON; SET ANSI_NULLS ON; DECLARE @ClusterId nvarchar(64) = 'modbus-smoke'; DECLARE @NodeId nvarchar(64) = 'modbus-smoke-node'; DECLARE @DrvId nvarchar(64) = 'modbus-smoke-drv'; DECLARE @DevId nvarchar(64) = 'modbus-smoke-dev'; DECLARE @AreaId nvarchar(64) = 'modbus-smoke-area'; DECLARE @LineId nvarchar(64) = 'modbus-smoke-line'; DECLARE @EqId nvarchar(64) = 'modbus-smoke-eq'; DECLARE @EqUuid uniqueidentifier = '72BD5A10-72BD-45A1-B72B-D5A1072BD5A1'; DECLARE @TagHr200 nvarchar(64) = 'modbus-smoke-tag-hr200'; DECLARE @RefId nvarchar(64) = 'modbus-smoke-ref-hr200'; BEGIN TRAN; -- Clean prior smoke state (child rows first). DELETE FROM dbo.UnsTagReference WHERE UnsTagReferenceId = @RefId; DELETE FROM dbo.Tag WHERE TagId = @TagHr200; DELETE FROM dbo.Equipment WHERE EquipmentId = @EqId; DELETE FROM dbo.UnsLine WHERE UnsLineId = @LineId; DELETE FROM dbo.UnsArea WHERE UnsAreaId = @AreaId; DELETE FROM dbo.Device WHERE DeviceId = @DevId; DELETE FROM dbo.DriverInstance WHERE DriverInstanceId = @DrvId; DELETE FROM dbo.ClusterNodeCredential WHERE NodeId = @NodeId; DELETE FROM dbo.ClusterNode WHERE NodeId = @NodeId; DELETE FROM dbo.ServerCluster WHERE ClusterId = @ClusterId; -- `UX_ClusterNodeCredential_Value` is a unique index on (Kind, Value) WHERE Enabled=1, so the -- `sa` login can only bind to one node at a time. Drop any prior smoke binding first. DELETE FROM dbo.ClusterNodeCredential WHERE Kind = 'SqlLogin' AND Value = 'sa'; -- 1. Cluster + Node + credential binding. INSERT dbo.ServerCluster(ClusterId, Name, Enterprise, Site, NodeCount, RedundancyMode, Enabled, CreatedBy) VALUES (@ClusterId, 'Modbus Smoke', 'zb', 'lab', 1, 'None', 1, 'modbus-smoke'); INSERT dbo.ClusterNode(NodeId, ClusterId, Host, OpcUaPort, DashboardPort, ApplicationUri, ServiceLevelBase, Enabled, CreatedBy) VALUES (@NodeId, @ClusterId, 'localhost', 4840, 15050, 'urn:OtOpcUa:modbus-smoke-node', 200, 1, 'modbus-smoke'); INSERT dbo.ClusterNodeCredential(NodeId, Kind, Value, Enabled, CreatedBy) VALUES (@NodeId, 'SqlLogin', 'sa', 1, 'modbus-smoke'); -- 2. Modbus DriverInstance at the cluster root (RawFolderId NULL). DriverConfig keeps protocol/ -- channel settings only — the endpoint (Host/Port/UnitId) now lives in the Device's DeviceConfig. INSERT dbo.DriverInstance(DriverInstanceId, ClusterId, RawFolderId, Name, DriverType, DriverConfig, Enabled) VALUES (@DrvId, @ClusterId, NULL, 'pymodbus-smoke', 'Modbus', N'{ "TimeoutMs": 2000, "AutoReconnect": true, "Probe": { "Enabled": true, "IntervalMs": 5000, "TimeoutMs": 2000, "ProbeAddress": 0 } }', 1); -- 3. Device — endpoint. DeviceConfig shape finalized against reworked options in Wave B (WP5). INSERT dbo.Device(DeviceId, DriverInstanceId, Name, Enabled, DeviceConfig) VALUES (@DevId, @DrvId, 'plc', 1, N'{ "Host": "127.0.0.1", "Port": 5020, "UnitId": 1 }'); -- 4. Raw tag under the device (identity = RawPath; TagConfig carries the driver address only). INSERT dbo.Tag(TagId, DeviceId, TagGroupId, Name, DataType, AccessLevel, WriteIdempotent, TagConfig) VALUES (@TagHr200, @DevId, NULL, 'HR200', 'UInt16', 'ReadWrite', 1, N'{ "region": "HoldingRegisters", "address": 200, "dataType": "UInt16", "writable": true }'); -- 5. UNS hierarchy + a reference projecting the raw tag into the equipment. INSERT dbo.UnsArea(UnsAreaId, ClusterId, Name) VALUES (@AreaId, @ClusterId, 'lab-floor'); INSERT dbo.UnsLine(UnsLineId, UnsAreaId, Name) VALUES (@LineId, @AreaId, 'modbus-line'); INSERT dbo.Equipment(EquipmentId, EquipmentUuid, UnsLineId, Name, MachineCode, Enabled) VALUES (@EqId, @EqUuid, @LineId, 'modbus-sim', 'modbus-001', 1); INSERT dbo.UnsTagReference(UnsTagReferenceId, EquipmentId, TagId, SortOrder) VALUES (@RefId, @EqId, @TagHr200, 0); COMMIT; PRINT ''; PRINT 'Modbus smoke seed complete (v3 schema).'; PRINT ' Cluster: ' + @ClusterId + ' Node: ' + @NodeId; PRINT ''; PRINT 'Next steps:'; PRINT ' 1. Set Server appsettings Node:NodeId = "modbus-smoke-node" / Node:ClusterId = "modbus-smoke"'; PRINT ' 2. docker compose -f tests/.../Modbus.IntegrationTests/Docker/docker-compose.yml --profile standard up -d'; PRINT ' 3. dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Server'; PRINT ' 4. Deploy the config via the AdminUI/ControlPlane, then ./scripts/e2e/test-modbus.ps1';