using System.Net.Sockets;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
///
/// Concrete Modbus TCP transport. Wraps a single and serializes
/// requests so at most one transaction is in-flight at a time — Modbus servers typically
/// support concurrent transactions, but the single-flight model keeps the wire trace
/// easy to diagnose and avoids interleaved-response correlation bugs.
///
///
///
/// Survives mid-transaction socket drops: when a send/read fails with a socket-level
/// error (, , )
/// the transport disposes the dead socket, reconnects, and retries the PDU exactly
/// once. Deliberately limited to a single retry — further failures bubble up so the
/// driver's health surface reflects the real state instead of masking a dead PLC.
///
///
/// Why this matters for DL205/DL260: the AutomationDirect H2-ECOM100 does NOT send
/// TCP keepalives per docs/v2/dl205.md §behavioral-oddities, so any NAT/firewall
/// between the gateway and PLC can silently close an idle socket after 2-5 minutes.
/// Also enables OS-level SO_KEEPALIVE so the driver's own side detects a stuck
/// socket in reasonable time even when the application is mostly idle.
///
///
public sealed class ModbusTcpTransport : IModbusTransport
{
private readonly string _host;
private readonly int _port;
private readonly TimeSpan _timeout;
private readonly bool _autoReconnect;
private readonly SemaphoreSlim _gate = new(1, 1);
private TcpClient? _client;
private NetworkStream? _stream;
private ushort _nextTx;
private bool _disposed;
public ModbusTcpTransport(string host, int port, TimeSpan timeout, bool autoReconnect = true)
{
_host = host;
_port = port;
_timeout = timeout;
_autoReconnect = autoReconnect;
}
public async Task ConnectAsync(CancellationToken ct)
{
// Resolve the host explicitly + prefer IPv4. .NET's TcpClient default-constructor is
// dual-stack (IPv6 first, fallback to IPv4) — but most Modbus TCP devices (PLCs and
// simulators like pymodbus) bind 0.0.0.0 only, so the IPv6 attempt times out and we
// burn the entire ConnectAsync budget before even trying IPv4. Resolving first +
// dialing the IPv4 address directly sidesteps that.
var addresses = await System.Net.Dns.GetHostAddressesAsync(_host, ct).ConfigureAwait(false);
var ipv4 = System.Linq.Enumerable.FirstOrDefault(addresses,
a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork);
var target = ipv4 ?? (addresses.Length > 0 ? addresses[0] : System.Net.IPAddress.Loopback);
_client = new TcpClient(target.AddressFamily);
EnableKeepAlive(_client);
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
cts.CancelAfter(_timeout);
await _client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
_stream = _client.GetStream();
}
///
/// Enable SO_KEEPALIVE with aggressive probe timing. DL205/DL260 doesn't send keepalives
/// itself; having the OS probe the socket every ~30s lets the driver notice a dead PLC
/// or broken NAT path long before the default 2-hour Windows idle timeout fires.
/// Non-fatal if the underlying OS rejects the option (some older Linux / container
/// sandboxes don't expose the fine-grained timing levers — the driver still works,
/// application-level probe still detects problems).
///
private static void EnableKeepAlive(TcpClient client)
{
try
{
client.Client.SetSocketOption(SocketOptionLevel.Socket, SocketOptionName.KeepAlive, true);
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveTime, 30);
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveInterval, 10);
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveRetryCount, 3);
}
catch { /* best-effort; older OSes may not expose the granular knobs */ }
}
public async Task SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
{
if (_disposed) throw new ObjectDisposedException(nameof(ModbusTcpTransport));
if (_stream is null) throw new InvalidOperationException("Transport not connected");
await _gate.WaitAsync(ct).ConfigureAwait(false);
try
{
try
{
return await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
}
catch (Exception ex) when (_autoReconnect && IsSocketLevelFailure(ex))
{
// Mid-transaction drop: tear down the dead socket, reconnect, resend. Single
// retry — if it fails again, let it propagate so health/status reflect reality.
await TearDownAsync().ConfigureAwait(false);
await ConnectAsync(ct).ConfigureAwait(false);
return await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
}
}
finally
{
_gate.Release();
}
}
private async Task SendOnceAsync(byte unitId, byte[] pdu, CancellationToken ct)
{
if (_stream is null) throw new InvalidOperationException("Transport not connected");
var txId = ++_nextTx;
// MBAP: [TxId(2)][Proto=0(2)][Length(2)][UnitId(1)] + PDU
var adu = new byte[7 + pdu.Length];
adu[0] = (byte)(txId >> 8);
adu[1] = (byte)(txId & 0xFF);
// protocol id already zero
var len = (ushort)(1 + pdu.Length); // unit id + pdu
adu[4] = (byte)(len >> 8);
adu[5] = (byte)(len & 0xFF);
adu[6] = unitId;
Buffer.BlockCopy(pdu, 0, adu, 7, pdu.Length);
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
cts.CancelAfter(_timeout);
await _stream.WriteAsync(adu.AsMemory(), cts.Token).ConfigureAwait(false);
await _stream.FlushAsync(cts.Token).ConfigureAwait(false);
var header = new byte[7];
await ReadExactlyAsync(_stream, header, cts.Token).ConfigureAwait(false);
var respTxId = (ushort)((header[0] << 8) | header[1]);
if (respTxId != txId)
throw new InvalidDataException($"Modbus TxId mismatch: expected {txId} got {respTxId}");
var respLen = (ushort)((header[4] << 8) | header[5]);
if (respLen < 1) throw new InvalidDataException($"Modbus response length too small: {respLen}");
var respPdu = new byte[respLen - 1];
await ReadExactlyAsync(_stream, respPdu, cts.Token).ConfigureAwait(false);
// Exception PDU: function code has high bit set.
if ((respPdu[0] & 0x80) != 0)
{
var fc = (byte)(respPdu[0] & 0x7F);
var ex = respPdu[1];
throw new ModbusException(fc, ex, $"Modbus exception fc={fc} code={ex}");
}
return respPdu;
}
///
/// Distinguish socket-layer failures (eligible for reconnect-and-retry) from
/// protocol-layer failures (must propagate — retrying the same PDU won't help if the
/// PLC just returned exception 02 Illegal Data Address).
///
private static bool IsSocketLevelFailure(Exception ex) =>
ex is EndOfStreamException
|| ex is IOException
|| ex is SocketException
|| ex is ObjectDisposedException;
private async Task TearDownAsync()
{
try { if (_stream is not null) await _stream.DisposeAsync().ConfigureAwait(false); }
catch { /* best-effort */ }
_stream = null;
try { _client?.Dispose(); } catch { }
_client = null;
}
private static async Task ReadExactlyAsync(Stream s, byte[] buf, CancellationToken ct)
{
var read = 0;
while (read < buf.Length)
{
var n = await s.ReadAsync(buf.AsMemory(read), ct).ConfigureAwait(false);
if (n == 0) throw new EndOfStreamException("Modbus socket closed mid-response");
read += n;
}
}
public async ValueTask DisposeAsync()
{
if (_disposed) return;
_disposed = true;
try
{
if (_stream is not null) await _stream.DisposeAsync().ConfigureAwait(false);
}
catch { /* best-effort */ }
_client?.Dispose();
_gate.Dispose();
}
}