using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Host.Domain;
namespace ZB.MOM.WW.OtOpcUa.Tests.Domain
{
public class SecurityClassificationMapperTests
{
///
/// Verifies that Galaxy classifications intended for operator and engineering writes remain writable through OPC UA.
///
/// The Galaxy security classification value being evaluated for write access.
/// The expected writable result for the supplied Galaxy classification.
[Theory]
[InlineData(0, true)] // FreeAccess
[InlineData(1, true)] // Operate
[InlineData(4, true)] // Tune
[InlineData(5, true)] // Configure
public void Writable_SecurityLevels(int classification, bool expected)
{
SecurityClassificationMapper.IsWritable(classification).ShouldBe(expected);
}
///
/// Verifies that secured or view-only Galaxy classifications are exposed as read-only attributes.
///
/// The Galaxy security classification value expected to block writes.
/// The expected writable result for the supplied read-only Galaxy classification.
[Theory]
[InlineData(2, false)] // SecuredWrite
[InlineData(3, false)] // VerifiedWrite
[InlineData(6, false)] // ViewOnly
public void ReadOnly_SecurityLevels(int classification, bool expected)
{
SecurityClassificationMapper.IsWritable(classification).ShouldBe(expected);
}
///
/// Verifies that unknown security classifications do not accidentally block writes for unmapped Galaxy values.
///
///
/// An unmapped Galaxy security classification value that should fall back to writable
/// behavior.
///
[Theory]
[InlineData(-1)]
[InlineData(7)]
[InlineData(99)]
public void Unknown_Values_DefaultToWritable(int classification)
{
SecurityClassificationMapper.IsWritable(classification).ShouldBeTrue();
}
}
}