/// Live gate for the read-batching layer: the block-read pass
/// (16-byte gap / 220-byte span defaults) and the multi-var leftover pass, both exercised against
/// the real python-snap7 S7-1500 fixture rather than a fake. The span defaults were chosen
/// analytically and the multi-var batching shipped with unit coverage only; this suite is what
/// proves they behave on real S7comm wire.
///
///
///
/// Live-gate record. Run 2026-08-17 against 10.100.0.35:1102
/// (otopcua-python-snap7-s7_1500, profile Docker/profiles/s7_1500.json):
/// PASSED — 3 tests, 0 failed, 0 skipped. Grouped batch collapsed 10 tags to 3 wire
/// requests (2 block reads + 1 three-item multi-var) and matched the ungrouped 10-request
/// batch value-for-value and type-for-type. No behavioural difference between the planner's
/// analytic model and real wire was found.
///
///
/// Re-run the same day against the same endpoint after the fixture gained its TM0 / CT0
/// areas: PASSED — 4 passed, 0 failed, 1 skipped (the device number-addressing test,
/// see below). The Timer/Counter batch was served by 4 requests for 7 tags: one DB1 span,
/// one 3-item multi-var carrying only the scalars, and one 2-byte area read apiece for
/// T0 (decoded 456.0 s from S5TIME 0x2456) and C0 (decoded count 4711).
///
///
/// What the layout buys. The ten tags are positioned so the planner's rules produce a
/// known, non-trivial partition rather than one that would pass by accident:
///
///
///
/// Cluster A (DB1.DBW300 … DB1.DBD316) — five tags whose largest hole is 5
/// bytes, so all five merge into ONE 20-byte span under the 16-byte gap budget. The
/// holes are seeded with poison (0xDEAD, 0xDEADBEEF) so a mis-computed
/// slice offset yields garbage rather than a zero that could coincidentally match.
///
///
/// Cluster B (DB1.DBW400 + DB1.DBW402) — 80 bytes past cluster A, so
/// the gap budget is what forces a SECOND span instead of one merged read. Two members
/// keep it clear of the PrefersPerTagRead demotion, so it is a real block read.
///
///
/// Leftovers (DB1.DBW500, DB1.DBW600, MW10) — each isolated
/// enough to form its own single-member span, each therefore demoted by
/// PrefersPerTagRead, and three of them is past MultiVarReadMinItems — so
/// they ride ONE multi-var request. MW10 is deliberately in a different area:
/// a block read can never merge across (area, DB), and the multi-var pass can,
/// so its presence in the single request is what pins that property live.
///
///
///
/// Timer / Counter ARE covered here now. The fixture profile grew TM0 + CT0 (64
/// bytes each = 32 device cells), so
/// pins the planner's
/// per-tag exclusion against real wire rather than a fake: a Timer and a Counter batched
/// alongside three multi-var-eligible scalars each take their own area-typed
/// ReadBytes round-trip, and the one multi-var request the scalars share carries
/// neither of them. Two independent guards produce that — the planner rejects them on AREA
/// (their offsets are device numbers, not byte addresses) and the multi-var pass on
/// IsBufferType.
///
///
/// ⚠️ Fixture limitation — only device 0 is addressable. Live-probed 2026-08-17:
/// snap7's server resolves the TM/CT request address as a BIT address (it serves byte
/// addr >> 3 of the area) where S7.Net — and a real S7 CPU — put the device
/// NUMBER in that field. Measured directly: ReadBytes(Timer, db 0, start 5, count 2)
/// returns TM bytes 0..1, and it takes start 80 (= 10 × 8) to reach the timer seeded
/// at TM byte 10. Device 0 is the single fixed point of the two conventions
/// (0 >> 3 == 2 × 0 == 0), so it is the only device this fixture can pin a
/// VALUE for, and that is what the mixed batch uses. The spec-correct 2 × N cells
/// are seeded too and
/// asserts
/// them — skipped unless S7_TIMER_NUMBER_ADDRESSING=1 declares the endpoint a real
/// CPU. The device-number offset arithmetic itself stays unit-covered
/// (S7ScalarBlockTests, S7SpanReadParityTests).
///
///
/// Why a counting factory rather than logs. The driver emits no log on a successful
/// grouped read, so the only honest way to assert the wire shape is to observe the calls.
/// decorates the REAL , so the
/// shipped S7PlcAdapter (and its S7OperationDeadline ceiling) stays on the
/// wire — the gate measures production's path, not a re-implementation of it.
///
///
[Collection(Snap7ServerCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "S7_1500")]
public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
{
///
/// Verifies the grouped batch returns exactly what reading every tag individually returns —
/// same values, same boxed CLR types, all Good.
///
///
/// Boxed equality is the assertion on purpose: the three paths decode through different code
/// (block slicing, S7.Net.ParseBytes via multi-var, and the per-address read), and a
/// path that returned the right number as the wrong CLR type would be a real defect that a
/// numeric-tolerance comparison would hide.
///
[Fact]
public async Task Grouped_batch_matches_ungrouped_reads_value_for_value()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var grouped = await ReadBatchAsync(SpanLayout.DefaultGapBytes, "s7-span-on");
var ungrouped = await ReadBatchAsync(SpanLayout.GroupingDisabled, "s7-span-off");
grouped.Snapshots.Count.ShouldBe(SpanLayout.TagNames.Count);
ungrouped.Snapshots.Count.ShouldBe(SpanLayout.TagNames.Count);
for (var i = 0; i < SpanLayout.TagNames.Count; i++)
{
var name = SpanLayout.TagNames[i];
grouped.Snapshots[i].StatusCode.ShouldBe(0u, $"grouped read of '{name}' must be Good");
ungrouped.Snapshots[i].StatusCode.ShouldBe(0u, $"ungrouped read of '{name}' must be Good");
grouped.Snapshots[i].Value.ShouldBe(
ungrouped.Snapshots[i].Value,
$"'{name}' must decode identically whichever path served it");
}
}
///
/// Verifies the grouped batch decodes the fixture's seeded values — so both paths agreeing
/// cannot mean "both wrong the same way".
///
///
/// Every seed is distinct and non-zero (the #536 trap: a zero-valued source proves nothing,
/// because a read that returned nothing at all would also read as zero). Distinctness matters
/// independently: two tags sharing a value would let a swapped slice offset pass.
///
[Fact]
public async Task Grouped_batch_decodes_the_seeded_values()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var grouped = await ReadBatchAsync(SpanLayout.DefaultGapBytes, "s7-span-seeds");
var byName = SpanLayout.TagNames
.Select((n, i) => (n, grouped.Snapshots[i]))
.ToDictionary(x => x.n, x => x.Item2);
foreach (var (name, snapshot) in byName)
snapshot.StatusCode.ShouldBe(0u, $"'{name}' must be Good");
// Cluster A — the five members of the single merged span.
byName["SpanA_U16"].Value.ShouldBe((ushort)51001);
byName["SpanA_I16"].Value.ShouldBe((short)-21001);
byName["SpanA_I32"].Value.ShouldBe(305419896);
byName["SpanA_Bool"].Value.ShouldBe(true);
Convert.ToSingle(byName["SpanA_F32"].Value).ShouldBe(2.7182817f, tolerance: 0.000001f);
// Cluster B — the second span.
byName["SpanB_U16a"].Value.ShouldBe((ushort)40201);
byName["SpanB_U16b"].Value.ShouldBe((ushort)40202);
// The multi-var leftovers, including the one in a different area.
byName["Lone_U16"].Value.ShouldBe((ushort)60001);
byName["Lone_I16"].Value.ShouldBe((short)-32001);
byName["Lone_MkU16"].Value.ShouldBe((ushort)4097);
}
///
/// Verifies the wire shape the batching actually produces against a live PLC: ten tags served
/// by three requests with grouping on, ten with it off.
///
///
/// This is the half of the gate that a value-parity test cannot cover — a driver that quietly
/// fell back to per-tag reads for every tag would pass parity perfectly while delivering none
/// of the round-trip saving the feature exists for. The off-case is asserted too, because
/// SpanReadMaxGapBytes < 0 is documented to restore the pre-grouping wire shape
/// EXACTLY, and "exactly" is a claim about requests, not values.
///
[Fact]
public async Task Grouping_collapses_ten_tags_to_three_wire_requests()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var grouped = await ReadBatchAsync(SpanLayout.DefaultGapBytes, "s7-span-shape-on");
grouped.Counters.BlockReads.ShouldBe(2,
"cluster A merges into one span and cluster B into a second; the gap budget separates them");
grouped.Counters.MultiVarReads.ShouldBe(1,
"the three demoted single-member spans are past MultiVarReadMinItems, so they share one request");
grouped.Counters.MultiVarItems.ShouldBe(3,
"all three leftovers ride that request — including MW10, which no block read could have joined");
grouped.Counters.AddressReads.ShouldBe(0,
"nothing in this batch should reach the per-tag path once both grouping passes have run");
grouped.Counters.TotalReadRequests.ShouldBe(3);
var ungrouped = await ReadBatchAsync(SpanLayout.GroupingDisabled, "s7-span-shape-off");
ungrouped.Counters.AddressReads.ShouldBe(SpanLayout.TagNames.Count,
"grouping off must restore one per-address read per tag");
ungrouped.Counters.BlockReads.ShouldBe(0);
ungrouped.Counters.MultiVarReads.ShouldBe(0,
"the multi-var pass rides the SAME switch as the span pass — disabling grouping must disable both");
ungrouped.Counters.TotalReadRequests.ShouldBe(SpanLayout.TagNames.Count);
}
///
/// Live pin for the planner's Timer/Counter exclusion: batched alongside three
/// multi-var-eligible scalars, a Timer and a Counter each take their own area-typed block
/// read and neither ever appears as an item of the multi-var request the scalars share.
///
///
///
/// The unit suite pins this against a fake (S7SpanReadParityTests
/// Timer_and_counter_leftovers_never_enter_a_multi_var_request); what only a live
/// run can add is that the excluded reads are ones a PLC actually answers — a driver
/// that put a Timer into a multi-var request would fault the WHOLE chunk on real wire,
/// taking the three innocent scalars down with it into the per-tag fallback. So the
/// scalars' values and the single 3-item request are asserted here too: they are the
/// evidence the exclusion is what kept the batch intact.
///
///
/// The Timer/Counter values are asserted at device 0 only — see the type remarks
/// for why this fixture cannot address any other device.
///
///
[Fact]
public async Task Timer_and_counter_tags_never_enter_a_multi_var_request()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var (snapshots, counters) = await ReadBatchAsync(
TimerCounterLayout.BuildOptions(sim.Host, sim.Port, TimerCounterLayout.MixedBatch),
TimerCounterLayout.Names(TimerCounterLayout.MixedBatch),
"s7-timer-counter");
var byName = TimerCounterLayout.Names(TimerCounterLayout.MixedBatch)
.Select((n, i) => (n, snapshots[i]))
.ToDictionary(x => x.n, x => x.Item2);
foreach (var (name, snapshot) in byName)
snapshot.StatusCode.ShouldBe(0u, $"'{name}' must be Good");
// (a) Correct decode off real wire. A Timer surfaces as the S5TIME word's duration in
// seconds (double) and a Counter as the raw count (int) — two different areas, two
// different values, two different CLR types, so a read that reached the wrong area or
// decoded through the wrong arm cannot pass.
byName["TC_Timer"].Value.ShouldBe(TimerCounterLayout.Device0TimerSeconds);
byName["TC_Counter"].Value.ShouldBe(TimerCounterLayout.Device0CounterCount);
// The co-batched scalars still decode to their own seeds — the exclusion protected them.
byName["TC_SpanB_U16a"].Value.ShouldBe((ushort)40201);
byName["TC_SpanB_U16b"].Value.ShouldBe((ushort)40202);
byName["TC_Lone_U16"].Value.ShouldBe((ushort)60001);
byName["TC_Lone_I16"].Value.ShouldBe((short)-32001);
byName["TC_Lone_Mk"].Value.ShouldBe((ushort)4097);
// (b) The wire shape. This is the pin: not one multi-var item carries a Timer or Counter.
counters.MultiVarReads.ShouldBe(1,
"the three isolated narrow scalars are past MultiVarReadMinItems, so they share one request");
counters.MultiVarItems.ShouldBe(3,
"exactly the three scalars — a Timer or Counter joining them would make this 4 or 5");
counters.MultiVarItemAreas.ShouldNotContain(S7NetDataType.Timer,
"a Timer must never be expressed as a multi-var item: its per-tag path decodes the S5TIME " +
"word itself and does not go through S7.Net's ParseBytes at all");
counters.MultiVarItemAreas.ShouldNotContain(S7NetDataType.Counter,
"a Counter must never be expressed as a multi-var item — same reason, plus its per-tag " +
"decode surfaces int where S7.Net's own Counter.FromByteArray returns ushort");
// …and they arrive instead as their own area-typed block reads, two bytes apiece (one
// S5TIME / counter word), with the device number in the start field. Asserting the shape
// rather than just the count is what distinguishes "excluded to a block read" from
// "excluded to the per-address string path", which is a different wire request entirely.
counters.BlockReadShapes.ShouldContain((S7NetDataType.Timer, 0, TimerCounterLayout.Device0, 2));
counters.BlockReadShapes.ShouldContain((S7NetDataType.Counter, 0, TimerCounterLayout.Device0, 2));
counters.BlockReadShapes.ShouldContain((S7NetDataType.DataBlock, 1, 400, 4),
"the two adjacent DB1 words still merge into one span, so this batch is a real three-way split");
counters.BlockReads.ShouldBe(3, "one span + one Timer + one Counter");
counters.AddressReads.ShouldBe(0,
"the Timer/Counter exclusion routes to the block-read seam, never to the per-address path");
}
///
/// Verifies a Timer and a Counter at NON-zero device numbers decode their seeded values —
/// the assertion the shared fixture cannot serve.
///
///
/// Skipped unless S7_TIMER_NUMBER_ADDRESSING=1 declares the endpoint a device
/// number-addressing CPU, because python-snap7's server is not one: it resolves the TM/CT
/// request address as a bit address, so T5 reads TM byte 0 rather than TM byte 10
/// (measured 2026-08-17 — see the type remarks). Set the variable alongside
/// S7_SIM_ENDPOINT when pointing this suite at a real S7 CPU seeded to match
/// Docker/profiles/s7_1500.json's TM/CT areas.
///
[Fact]
public async Task Timer_and_counter_decode_the_seeded_values_at_their_device_numbers()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (Environment.GetEnvironmentVariable(TimerCounterLayout.RealCpuEnvVar) != "1")
{
Assert.Skip(
$"python-snap7's server resolves a TM/CT request address as a BIT address (byte = addr>>3), " +
$"not as a device number, so only device 0 is reachable on the fixture. " +
$"Set {TimerCounterLayout.RealCpuEnvVar}=1 (with S7_SIM_ENDPOINT pointing at a real S7 CPU " +
$"seeded like Docker/profiles/s7_1500.json) to run this.");
}
var (snapshots, _) = await ReadBatchAsync(
TimerCounterLayout.BuildOptions(sim.Host, sim.Port, TimerCounterLayout.DeviceNumbered),
TimerCounterLayout.Names(TimerCounterLayout.DeviceNumbered),
"s7-timer-counter-devnum");
snapshots[0].StatusCode.ShouldBe(0u, "'TC_Timer5' must be Good");
snapshots[1].StatusCode.ShouldBe(0u, "'TC_Counter7' must be Good");
snapshots[0].Value.ShouldBe(12.3d, "T5 holds S5TIME 0x1123 — base 0.1 s, BCD 123");
snapshots[1].Value.ShouldBe(31337, "C7 holds the raw count word 31337");
}
/// Reads the whole span layout once through a freshly-built driver and reports the wire shape.
/// The span budget: the shipped default, or a negative value to disable grouping.
/// Instance id, distinct per call so log lines stay attributable.
/// The batch's snapshots plus the wire-call counts observed for the read itself.
private Task<(IReadOnlyList Snapshots, CountingPlcFactory Counters)>
ReadBatchAsync(int maxGapBytes, string driverInstanceId)
=> ReadBatchAsync(
SpanLayout.BuildOptions(sim.Host, sim.Port, maxGapBytes), SpanLayout.TagNames, driverInstanceId);
/// Reads one batch through a freshly-built driver and reports the wire shape.
/// Driver options carrying the layout's raw tags and span budget.
/// The references to read, in the order the driver is asked for them.
/// Instance id, distinct per call so log lines stay attributable.
/// The batch's snapshots plus the wire-call counts observed for the read itself.
private static async Task<(IReadOnlyList Snapshots, CountingPlcFactory Counters)>
ReadBatchAsync(S7DriverOptions options, IReadOnlyList tagNames, string driverInstanceId)
{
var counters = new CountingPlcFactory(new S7PlcFactory());
await using var drv = new S7Driver(options, driverInstanceId, counters);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
// Initialization may open the connection and probe; only the batch's own wire calls are the
// subject here, so the counters start from zero at the read.
counters.Reset();
var snapshots = await drv.ReadAsync(tagNames, TestContext.Current.CancellationToken);
return (snapshots, counters);
}
///
/// The tag layout under test, positioned against the shipped 16-byte gap / 220-byte span
/// defaults so the planner produces a known partition. Addresses map 1:1 to the seed offsets
/// in Docker/profiles/s7_1500.json, so a seed drift there surfaces here as a value
/// mismatch rather than a mystery failure.
///
private static class SpanLayout
{
/// The shipped gap budget — the value this gate exists to validate.
public const int DefaultGapBytes = S7DriverOptions.DefaultSpanReadMaxGapBytes;
/// Any negative gap disables BOTH grouping passes; the documented off switch.
public const int GroupingDisabled = -1;
private static readonly S7TagDefinition[] Definitions =
[
// Cluster A: holes of 0, 0, 2 and 5 bytes — all inside the 16-byte budget, so these five
// merge into one 300..320 span (20 bytes, far under the 220-byte ceiling).
new("SpanA_U16", "DB1.DBW300", S7DataType.UInt16),
new("SpanA_I16", "DB1.DBW302", S7DataType.Int16),
new("SpanA_I32", "DB1.DBD304", S7DataType.Int32),
new("SpanA_Bool", "DB1.DBX310.5", S7DataType.Bool),
new("SpanA_F32", "DB1.DBD316", S7DataType.Float32),
// Cluster B: 80 bytes past cluster A's end, so the budget forces a second span. Two
// members, so PrefersPerTagRead cannot demote it to the per-tag path.
new("SpanB_U16a", "DB1.DBW400", S7DataType.UInt16),
new("SpanB_U16b", "DB1.DBW402", S7DataType.UInt16),
// Leftovers: each far enough from every neighbour to form a single-member span, hence
// demoted, hence batched by the multi-var pass. MW10 is in another area entirely.
new("Lone_U16", "DB1.DBW500", S7DataType.UInt16),
new("Lone_I16", "DB1.DBW600", S7DataType.Int16),
new("Lone_MkU16", "MW10", S7DataType.UInt16),
];
/// The batch's references, in the order the driver is asked for them.
public static readonly IReadOnlyList TagNames = [.. Definitions.Select(d => d.Name)];
/// Builds driver options for the layout at the requested span budget.
/// The fixture hostname or IP address.
/// The fixture port.
/// Span gap budget; negative disables grouping.
/// The driver options.
public static S7DriverOptions BuildOptions(string host, int port, int maxGapBytes) => new()
{
Host = host,
Port = port,
CpuType = S7CpuType.S71500,
Rack = 0,
Slot = 0,
Timeout = TimeSpan.FromSeconds(5),
// Same reasoning as the smoke profile: a background probe would race these reads for the
// connection gate and would also pollute the wire-shape counts this suite asserts on.
Probe = new S7ProbeOptions { Enabled = false },
SpanReadMaxGapBytes = maxGapBytes,
SpanReadMaxSpanBytes = S7DriverOptions.DefaultSpanReadMaxSpanBytes,
RawTags = S7RawTags.Entries(Definitions),
};
}
///
/// The Timer/Counter layouts. Two sets: a mixed batch that provokes all three read shapes at
/// once (block span, multi-var, per-tag Timer/Counter), and a device-numbered pair only a
/// real CPU can serve. Addresses map 1:1 to the TM0 / CT0 seeds in
/// Docker/profiles/s7_1500.json.
///
private static class TimerCounterLayout
{
/// Declares the endpoint a real S7 CPU, which addresses TM/CT by device number.
public const string RealCpuEnvVar = "S7_TIMER_NUMBER_ADDRESSING";
///
/// The one device number snap7's bit-address resolution and a CPU's device-number
/// resolution both land on: 0 >> 3 == 2 × 0 == 0.
///
public const int Device0 = 0;
/// T0's seed 0x2456 — S5TIME base 2 (×1 s) over BCD 456.
public const double Device0TimerSeconds = 456.0d;
/// C0's seed — the raw big-endian count word.
public const int Device0CounterCount = 4711;
///
/// A Timer and a Counter batched with scalars laid out to produce every other read shape:
/// two adjacent DB1 words (one merged span) and three isolated narrow scalars, one of
/// them in another area (one 3-item multi-var request).
///
public static readonly S7TagDefinition[] MixedBatch =
[
new("TC_SpanB_U16a", "DB1.DBW400", S7DataType.UInt16),
new("TC_SpanB_U16b", "DB1.DBW402", S7DataType.UInt16),
new("TC_Lone_U16", "DB1.DBW500", S7DataType.UInt16),
new("TC_Lone_I16", "DB1.DBW600", S7DataType.Int16),
new("TC_Lone_Mk", "MW10", S7DataType.UInt16),
// Timer tags are typed Float64 (decoded to seconds) and Counter tags Int32 (decoded to
// a count) — the init guard rejects any other typing. Writable:false is mandatory, not
// stylistic: S7TagDefinition defaults Writable to TRUE and the same guard rejects a
// writable Timer/Counter outright (they are read-only this phase).
new("TC_Timer", "T0", S7DataType.Float64, Writable: false),
new("TC_Counter", "C0", S7DataType.Int32, Writable: false),
];
/// The non-zero device numbers, reachable only from a device number-addressing CPU.
public static readonly S7TagDefinition[] DeviceNumbered =
[
new("TC_Timer5", "T5", S7DataType.Float64, Writable: false),
new("TC_Counter7", "C7", S7DataType.Int32, Writable: false),
];
/// The batch's references, in the order the driver is asked for them.
/// The definition set.
/// The tag names.
public static IReadOnlyList Names(IReadOnlyList defs)
=> [.. defs.Select(d => d.Name)];
/// Builds driver options for one definition set at the shipped span budget.
/// The fixture hostname or IP address.
/// The fixture port.
/// The definition set.
/// The driver options.
public static S7DriverOptions BuildOptions(string host, int port, S7TagDefinition[] defs) => new()
{
Host = host,
Port = port,
CpuType = S7CpuType.S71500,
Rack = 0,
Slot = 0,
Timeout = TimeSpan.FromSeconds(5),
// As in SpanLayout: a background probe would race the read for the connection gate and
// pollute the wire-shape counts.
Probe = new S7ProbeOptions { Enabled = false },
SpanReadMaxGapBytes = SpanLayout.DefaultGapBytes,
SpanReadMaxSpanBytes = S7DriverOptions.DefaultSpanReadMaxSpanBytes,
RawTags = S7RawTags.Entries(defs),
};
}
///
/// decorator that counts the read calls the driver makes, so a
/// test can assert the wire shape rather than infer it. Delegates to the real factory, so
/// every counted call is the one production would have issued.
///
///
/// Not thread-safe, by design. Every ReadBatchAsync builds its own factory and
/// the driver serialises all wire calls on its _gate, so nothing here is ever touched
/// concurrently today. A future caller that shared one factory across parallel reads would
/// silently corrupt the counts and shape lists rather than fail loudly — give it a lock, or
/// a factory per batch, before doing that.
///
/// The factory producing the real connection.
private sealed class CountingPlcFactory(IS7PlcFactory inner) : IS7PlcFactory
{
private readonly List<(S7NetDataType Area, int Db, int Start, int Count)> _blockReadShapes = [];
private readonly List _multiVarItemAreas = [];
/// Block reads issued — one per planned span.
public int BlockReads { get; private set; }
///
/// The (area, DB, start, count) of every block read, in issue order. Counting
/// alone cannot tell a Timer's own 2-byte area read from a span's — the shape can.
///
public IReadOnlyList<(S7NetDataType Area, int Db, int Start, int Count)> BlockReadShapes
=> _blockReadShapes;
///
/// The area of every item carried by every multi-var request. A Timer or Counter
/// appearing here is the exact defect the planner's exclusion exists to prevent.
///
public IReadOnlyList MultiVarItemAreas => _multiVarItemAreas;
/// Multi-var requests issued — one per leftover chunk.
public int MultiVarReads { get; private set; }
/// Items carried across all multi-var requests.
public int MultiVarItems { get; private set; }
/// Per-address reads issued — the unchanged per-tag path.
public int AddressReads { get; private set; }
/// Total read round-trips, whichever shape they took.
public int TotalReadRequests => BlockReads + MultiVarReads + AddressReads;
/// Zeroes the counters, so a batch can be measured without initialization's calls.
public void Reset()
{
BlockReads = 0;
MultiVarReads = 0;
MultiVarItems = 0;
AddressReads = 0;
_blockReadShapes.Clear();
_multiVarItemAreas.Clear();
}
///
public IS7Plc Create(S7CpuType cpuType, string host, int port, short rack, short slot, TimeSpan timeout)
=> new CountingPlc(inner.Create(cpuType, host, port, rack, slot, timeout), this);
private void CountBlockRead(S7NetDataType area, int db, int start, int count)
{
BlockReads++;
_blockReadShapes.Add((area, db, start, count));
}
private void CountMultiVarRead(IReadOnlyList? items)
{
MultiVarReads++;
MultiVarItems += items?.Count ?? 0;
if (items is null) return;
foreach (var item in items) _multiVarItemAreas.Add(item.DataType);
}
private void CountAddressRead() => AddressReads++;
/// Counting pass-through over one real connection.
/// The real connection.
/// The factory holding the counters.
private sealed class CountingPlc(IS7Plc inner, CountingPlcFactory owner) : IS7Plc
{
///
public bool IsConnected => inner.IsConnected;
///
public Task OpenAsync(CancellationToken cancellationToken) => inner.OpenAsync(cancellationToken);
///
public void Close() => inner.Close();
///
public Task