using System.Net.Sockets;
using Xunit;
using Xunit.Sdk;
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests;
///
/// Reachability probe for the ab_server Docker container running in a PCCC
/// plc mode (SLC500 / Micrologix / PLC/5). Same container image
/// the AB CIP integration suite uses — libplctag's ab_server supports both
/// CIP + PCCC families from one binary. Tests skip via
/// / when
/// the port isn't live, so dotnet test stays green on a fresh clone without
/// Docker running.
///
///
/// Env-var overrides:
///
/// - AB_LEGACY_ENDPOINT — host:port of a single PCCC-mode device, pinning
/// every family to it (real-hardware mode, where the family is a property of the device
/// rather than of the port). Unset — the default — each family is reached on its own port on the
/// shared Docker host: 10.100.0.35:44819 slc500, :44820 micrologix,
/// :44821 plc5.
/// - AB_LEGACY_CIP_PATH — routing path appended to the ab://host:port/
/// URI. Defaults to 1,0 (port-1/slot-0 backplane), required by ab_server
/// which rejects unconnected Send_RR_Data with an empty path at the CIP layer
/// before the PCCC dispatcher runs. Real SLC 5/05 / MicroLogix / PLC-5 hardware
/// use an empty path — set AB_LEGACY_CIP_PATH= (empty) when pointing at
/// real hardware.
///
/// Distinct from AB_SERVER_ENDPOINT used by the AB CIP fixture so both can point at different
/// containers simultaneously during a combined test run — which was the stated intent from the start
/// but was not true in practice until 2026-08-01, because every ab_server across both fixtures
/// defaulted to :44818.
///
public sealed class AbLegacyServerFixture : IAsyncLifetime
{
private const string EndpointEnvVar = "AB_LEGACY_ENDPOINT";
private const string CipPathEnvVar = "AB_LEGACY_CIP_PATH";
/// Standard EtherNet/IP port. PCCC-over-CIP rides on the same port as
/// native CIP; the differentiator is the --plc flag ab_server was started
/// with, not a different TCP listener.
public const int DefaultPort = 44818;
///
/// ab_server rejects unconnected Send_RR_Data with an empty CIP routing path
/// at the CIP layer — the PCCC dispatcher never runs. 1,0 is the generic
/// port-1/slot-0 backplane path; any well-formed path passes the gate. Real
/// hardware (SLC 5/05 / MicroLogix / PLC-5) uses an empty path because there's
/// no backplane to cross, so point AB_LEGACY_CIP_PATH= (empty) at real
/// hardware to exercise the authentic wire semantics.
///
public const string DefaultCipPath = "1,0";
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
// off this VM's 127.0.0.1 on 2026-04-28 alongside the rest of the Docker-host move.
// Override via AB_LEGACY_ENDPOINT to point at a real PLC or a locally-running container.
/// Gets the server host address.
public string Host { get; } = "10.100.0.35";
///
/// The port every family shares when AB_LEGACY_ENDPOINT pins one, or
/// . Prefer — against the Docker fixture each
/// family listens on its own port and this value addresses none of them.
///
public int Port { get; } = DefaultPort;
/// True when AB_LEGACY_ENDPOINT pinned a single endpoint (real-hardware mode).
public bool EndpointPinned { get; }
///
/// The port to reach 's simulator on: the family's own port against the
/// Docker fixture, or the pinned endpoint's port when AB_LEGACY_ENDPOINT is set.
///
/// The family profile under test.
/// The TCP port.
public int PortFor(AbLegacyServerProfile profile)
{
ArgumentNullException.ThrowIfNull(profile);
return EndpointPinned ? Port : profile.Port;
}
///
/// Why 's simulator cannot be reached, or null when it can.
///
///
/// ⚠️ Per-family, not per-suite (2026-08-01). Every family used to share :44818, so
/// this could only ever answer "is some ab_server up" — and the AB CIP fixture's ControlLogix
/// container answers there too. The probe therefore reported reachable, the suite declined to
/// skip, and SLC500-mode PCCC ran against a ControlLogix and failed at the wire. A reachability
/// check that cannot tell one simulator from another is not a skip gate; it is a coin flip that
/// reports its result as a test failure.
///
/// The family profile under test.
/// A skip reason, or .
public string? SkipReasonFor(AbLegacyServerProfile profile)
{
ArgumentNullException.ThrowIfNull(profile);
var port = PortFor(profile);
if (TcpProbe(Host, port)) return null;
return EndpointPinned
? $"AB Legacy PCCC endpoint at {Host}:{port} ({EndpointEnvVar}) not reachable within 2 s."
: $"AB Legacy {profile.ComposeProfile} simulator at {Host}:{port} not reachable within 2 s. "
+ $"Start it (docker compose -f Docker/docker-compose.yml --profile {profile.ComposeProfile} "
+ $"up -d), attach real hardware, or override {EndpointEnvVar}.";
}
/// CIP routing path portion of the device URI (after the / separator).
/// May be empty when targeting real hardware; non-empty against ab_server.
public string CipPath { get; } = DefaultCipPath;
/// Initializes the AB Legacy server fixture by reading environment overrides.
public AbLegacyServerFixture()
{
if (Environment.GetEnvironmentVariable(EndpointEnvVar) is { Length: > 0 } raw)
{
var parts = raw.Split(':', 2);
Host = parts[0];
if (parts.Length == 2 && int.TryParse(parts[1], out var p)) Port = p;
EndpointPinned = true;
}
// Empty override is intentional (real hardware); treat `null` as "not set, use
// default" but preserve an explicit empty-string override.
var cipOverride = Environment.GetEnvironmentVariable(CipPathEnvVar);
if (cipOverride is not null) CipPath = cipOverride;
}
/// Initializes the fixture asynchronously.
public ValueTask InitializeAsync() => ValueTask.CompletedTask;
/// Disposes the fixture asynchronously.
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
///
/// Used by +
/// during test-class construction — gates whether the test runs at all. Duplicates the
/// fixture logic because attribute ctors fire before the collection fixture instance
/// exists.
///
public static bool IsServerAvailable()
{
var raw = Environment.GetEnvironmentVariable(EndpointEnvVar);
if (raw is { Length: > 0 })
{
var parts = raw.Split(':', 2);
var pinned = parts.Length == 2 && int.TryParse(parts[1], out var p) ? p : DefaultPort;
return TcpProbe(parts[0], pinned);
}
// ANY family's simulator being up runs the class; each test then skips itself on its own port
// via SkipReasonFor. Gating the whole class on one family would skip the other two whenever it
// happened to be down, which reads as coverage that ran.
return KnownProfiles.All.Any(profile => TcpProbe("10.100.0.35", profile.Port));
}
private static bool TcpProbe(string host, int port)
{
try
{
using var client = new TcpClient();
var task = client.ConnectAsync(host, port);
return task.Wait(TimeSpan.FromSeconds(2)) && client.Connected;
}
catch { return false; }
}
}
///
/// Per-family marker for the PCCC-mode compose profile a given test targets. The
/// compose file (Docker/docker-compose.yml) is the canonical source of truth
/// for which --plc mode + tags each family seeds; this record just ties a
/// family enum to its compose-profile name + operator-facing notes.
///
/// The PCCC family.
/// The compose profile name that starts this family's container.
///
/// The family's own host port. Each family gets one so all three run together, and alongside the
/// AB CIP fixture on :44818. Overridden wholesale by AB_LEGACY_ENDPOINT (real hardware,
/// where there is one device and the family is a property of it, not of the port).
///
/// Operator-facing description of what the family's container seeds.
public sealed record AbLegacyServerProfile(
AbLegacyPlcFamily Family,
string ComposeProfile,
int Port,
string Notes);
/// Canonical profiles covering every PCCC family the driver supports.
///
/// The Port values must match Docker/docker-compose.yml's host-side mappings.
///
public static class KnownProfiles
{
public static readonly AbLegacyServerProfile Slc500 = new(
Family: AbLegacyPlcFamily.Slc500,
ComposeProfile: "slc500",
Port: 44819,
Notes: "SLC 500 / 5/05 family. ab_server SLC500 mode covers N/F/B/L files.");
public static readonly AbLegacyServerProfile MicroLogix = new(
Family: AbLegacyPlcFamily.MicroLogix,
ComposeProfile: "micrologix",
Port: 44820,
Notes: "MicroLogix 1000 / 1100 / 1400. Shares N/F/B file-type coverage with SLC500; ST (ASCII strings) included.");
public static readonly AbLegacyServerProfile Plc5 = new(
Family: AbLegacyPlcFamily.Plc5,
ComposeProfile: "plc5",
Port: 44821,
Notes: "PLC-5 family. ab_server PLC/5 mode covers N/F/B; per-family quirks on ST / timer file layouts unit-tested only.");
/// Gets all known profiles.
public static IReadOnlyList All { get; } =
[Slc500, MicroLogix, Plc5];
/// Gets the profile for the specified PLC family.
/// The PLC family.
public static AbLegacyServerProfile ForFamily(AbLegacyPlcFamily family) =>
All.FirstOrDefault(p => p.Family == family)
?? throw new ArgumentOutOfRangeException(nameof(family), family, "No integration profile for this family.");
}
[Xunit.CollectionDefinition(Name)]
public sealed class AbLegacyServerCollection : Xunit.ICollectionFixture
{
public const string Name = "AbLegacyServer";
}
///
/// [Fact]-equivalent that skips when the PCCC endpoint isn't reachable.
/// See for the exact skip semantics.
///
public sealed class AbLegacyFactAttribute : FactAttribute
{
/// Initializes the attribute, skipping the test if the server is unavailable.
public AbLegacyFactAttribute()
{
if (!AbLegacyServerFixture.IsServerAvailable())
Skip = "AB Legacy PCCC endpoint not reachable. Start the Docker fixture " +
"(docker compose -f Docker/docker-compose.yml --profile slc500 up -d) " +
"or point AB_LEGACY_ENDPOINT at real hardware.";
}
}
///
/// [Theory]-equivalent with the same gate as .
///
public sealed class AbLegacyTheoryAttribute : TheoryAttribute
{
/// Initializes the attribute, skipping the test if the server is unavailable.
public AbLegacyTheoryAttribute()
{
if (!AbLegacyServerFixture.IsServerAvailable())
Skip = "AB Legacy PCCC endpoint not reachable. Start the Docker fixture " +
"(docker compose -f Docker/docker-compose.yml --profile slc500 up -d) " +
"or point AB_LEGACY_ENDPOINT at real hardware.";
}
}