# logix-read-dint-array16.hex # client : libplctag 1.5.2 (libplctag.NET wrapper; libplctag.NativeImport 1.0.41, native core 2.6.0) # server : otopcua-ab-server:libplctag-release (ab_server from libplctag v2.7.0 + patches 0001/0002) # profile: controllogix # tag : protocol=ab_eip&gateway=10.100.0.35:44818&path=1,0&plc=controllogix&name=TestArray&elem_count=16 # session: logix-read-dint-array16 (captured 2026-10-07, scripts/ab-capture/capture.sh) # frames : Two connected 0x52 exchanges for 16 DINT elements (Initialize read + explicit Read). Seeded first (client write ... dintseq): element i (0-based) = ((i+1) << 24) | (i+1), i.e. 0x01000001, 0x02000002 ... 0x10000010. > 70002A00F43B6DB3000000000000000000000000000000000000000001000200A1000400A07474F5B100160001005206910954657374417272617900100000000000 < 70005C00F43B6DB3000000000000000000000000000000000000000001000200A1000400943EDA10B10048000100D2000000C4000100000102000002030000030400000405000005060000060700000708000008090000090A00000A0B00000B0C00000C0D00000D0E00000E0F00000F10000010 > 70002A00F43B6DB3000000000000000000000000000000000000000001000200A1000400A07474F5B100160002005206910954657374417272617900100000000000 < 70005C00F43B6DB3000000000000000000000000000000000000000001000200A1000400943EDA10B10048000200D2000000C4000100000102000002030000030400000405000005060000060700000708000008090000090A00000A0B00000B0C00000C0D00000D0E00000E0F00000F10000010