using Opc.Ua;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Commands;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Tests.Fakes;
namespace ZB.MOM.WW.OtOpcUa.Client.CLI.Tests;
public class ReadCommandTests
{
/// Verifies that execute prints the read value.
[Fact]
public async Task Execute_PrintsReadValue()
{
var sourceTime = new DateTime(2025, 6, 15, 10, 30, 0, DateTimeKind.Utc);
var serverTime = new DateTime(2025, 6, 15, 10, 30, 1, DateTimeKind.Utc);
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(
new Variant("Hello"),
StatusCodes.Good,
sourceTime,
serverTime)
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
var output = TestConsoleHelper.GetOutput(console);
output.ShouldContain("Node: ns=2;s=TestNode");
output.ShouldContain("Value: Hello");
output.ShouldContain("Status:");
output.ShouldContain("Source Time:");
output.ShouldContain("Server Time:");
}
/// Verifies that execute calls read value with correct node ID.
[Fact]
public async Task Execute_CallsReadValueWithCorrectNodeId()
{
var fakeService = new FakeOpcUaClientService();
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=MyVariable"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
fakeService.ReadNodeIds.Count.ShouldBe(1);
fakeService.ReadNodeIds[0].Identifier.ShouldBe("MyVariable");
}
/// Verifies that execute disconnects in finally.
[Fact]
public async Task Execute_DisconnectsInFinally()
{
var fakeService = new FakeOpcUaClientService();
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
fakeService.DisconnectCalled.ShouldBeTrue();
fakeService.DisposeCalled.ShouldBeTrue();
}
/// Verifies that execute disconnects even on read error.
[Fact]
public async Task Execute_DisconnectsEvenOnReadError()
{
var fakeService = new FakeOpcUaClientService
{
ReadException = new InvalidOperationException("Read failed")
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await Should.ThrowAsync(async () => await command.ExecuteAsync(console));
fakeService.DisconnectCalled.ShouldBeTrue();
fakeService.DisposeCalled.ShouldBeTrue();
}
}