using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli.Commands;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli.Tests;
///
/// Covers the --value string → CLR type parser inside
/// . This is the piece that guards against
/// locale surprises (e.g. comma-as-decimal-separator on PL locales), so all numeric
/// paths assert the invariant-culture path.
///
[Trait("Category", "Unit")]
public sealed class WriteCommandParseValueTests
{
[Theory]
[InlineData("true", true)]
[InlineData("false", false)]
[InlineData("1", true)]
[InlineData("0", false)]
[InlineData("YES", true)]
[InlineData("No", false)]
[InlineData("on", true)]
[InlineData("off", false)]
public void ParseValue_Bool_accepts_common_aliases(string raw, bool expected)
{
WriteCommand.ParseValue(raw, ModbusDataType.Bool).ShouldBe(expected);
}
[Fact]
public void ParseValue_Bool_rejects_unknown_strings()
{
Should.Throw(
() => WriteCommand.ParseValue("maybe", ModbusDataType.Bool));
}
[Fact]
public void ParseValue_Int16_parses_positive_and_negative()
{
WriteCommand.ParseValue("-32768", ModbusDataType.Int16).ShouldBe((short)-32768);
WriteCommand.ParseValue("32767", ModbusDataType.Int16).ShouldBe((short)32767);
}
[Fact]
public void ParseValue_UInt16_and_Bcd16_both_yield_ushort()
{
WriteCommand.ParseValue("65535", ModbusDataType.UInt16).ShouldBeOfType();
WriteCommand.ParseValue("65535", ModbusDataType.Bcd16).ShouldBeOfType();
}
[Fact]
public void ParseValue_Float32_uses_invariant_culture_period_as_decimal_separator()
{
WriteCommand.ParseValue("3.14", ModbusDataType.Float32).ShouldBe(3.14f);
}
[Fact]
public void ParseValue_Float64_handles_larger_precision()
{
var result = WriteCommand.ParseValue("2.718281828", ModbusDataType.Float64);
result.ShouldBeOfType();
((double)result).ShouldBe(2.718281828d, 0.0000001d);
}
[Fact]
public void ParseValue_String_returns_raw_string_unmodified()
{
WriteCommand.ParseValue("hello world", ModbusDataType.String).ShouldBe("hello world");
}
[Fact]
public void ParseValue_BitInRegister_accepts_bool_aliases()
{
WriteCommand.ParseValue("true", ModbusDataType.BitInRegister).ShouldBe(true);
WriteCommand.ParseValue("0", ModbusDataType.BitInRegister).ShouldBe(false);
}
[Fact]
public void ParseValue_Int32_parses_negative_max()
{
WriteCommand.ParseValue("-2147483648", ModbusDataType.Int32).ShouldBe(int.MinValue);
}
[Fact]
public void ParseValue_rejects_non_numeric_for_numeric_types()
{
Should.Throw(
() => WriteCommand.ParseValue("not-a-number", ModbusDataType.Int32));
}
}