# S7 integration-test fixture — python-snap7 [python-snap7](https://github.com/gijzelaerr/python-snap7) `Server` class wrapped in a pinned `python:3.12-slim-bookworm` image. Docker is the only supported launch path — a fresh clone needs Docker Desktop and nothing else. | File | Purpose | |---|---| | [`Dockerfile`](Dockerfile) | `python:3.12-slim-bookworm` + `python-snap7>=2.0` + the server shim + the profile JSONs | | [`docker-compose.yml`](docker-compose.yml) | One service per profile; currently only `s7_1500` | | [`server.py`](server.py) | Same Python shim the native fallback uses — copy kept in the build context | | [`profiles/*.json`](profiles/) | Area-seed definitions (DB1 / MB layouts with typed seeds) | ## Run From the repo root: ```powershell docker compose -f tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests\Docker\docker-compose.yml --profile s7_1500 up ``` Detached + stop: ```powershell docker compose -f tests\...\Docker\docker-compose.yml --profile s7_1500 up -d docker compose -f tests\...\Docker\docker-compose.yml --profile s7_1500 down ``` ### ⚠️ Editing a profile requires `--build` `Dockerfile` **COPYs `profiles/` into the image**, so the seeds are baked in at build time — they are not bind-mounted. A plain `up -d`, and even `up -d --force-recreate`, reuses the existing `otopcua-python-snap7:1.0` image and silently keeps serving the OLD seeds. After editing a profile JSON: ```bash docker compose --profile s7_1500 up -d --build --force-recreate ``` Confirm it took: `docker logs otopcua-python-snap7-s7_1500` prints `seeded DB1 size=1024 seeds=` at startup — check `` matches the seed count you just wrote. This is the fastest way to tell a stale image from a bad address. On the shared Docker host the deployment mirror at `/opt/otopcua-s7/` is **root-owned**, so a plain `rsync` fails with `status 23` and leaves the old files in place while still printing the file list. Push with: ```bash rsync -av --rsync-path="sudo rsync" \ tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ \ dohertj2@10.100.0.35:/opt/otopcua-s7/ ``` ## Endpoint - Default: `localhost:1102` (non-privileged; sidesteps Windows Firewall prompt + Linux's root-required bind on port 102). - Override with `S7_SIM_ENDPOINT` to point at a real S7 CPU on `:102`. - The driver's S7DriverOptions.Port flows through S7netplus's 5-arg `Plc(CpuType, host, port, rack, slot)` ctor so the non-standard port works end-to-end. ## Run the integration tests In a separate shell with the container up: ```powershell cd C:\Users\dohertj2\Desktop\lmxopcua dotnet test tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests ``` `Snap7ServerFixture` probes `localhost:1102` at collection init + records a `SkipReason` when unreachable, so tests stay green on a fresh clone without Docker running. ## What's encoded in `profiles/s7_1500.json` DB1 (1024 bytes) + MB (256 bytes) with typed seeds at known offsets: | Address | Type | Seed | Purpose | |---|---|---|---| | `DB1.DBW0` | u16 | `4242` | read-back probe | | `DB1.DBW10` | i16 | `-12345` | smoke i16 read | | `DB1.DBD20` | i32 | `1234567890` | smoke i32 read | | `DB1.DBD30` | f32 | `3.14159` | smoke f32 read (big-endian) | | `DB1.DBX50.3` | bool | `true` | smoke bool read at bit 3 | | `DB1.DBW100` | u16 | `0` | scratch for write-then-read | | `DB1.STRING[200]` | S7 STRING | `"Hello"` | S7 STRING read | | `MW0` | u16 | `1` | `S7ProbeOptions.ProbeAddress` default | Seed types supported: `u8`, `i8`, `u16`, `i16`, `u32`, `i32`, `f32`, `bool` (with `"bit": 0..7`), `ascii` (S7 STRING). ### Span-planner gate seeds (offsets 300+, `S7_1500SpanReadTests`) These exist to give `S7ReadSpanPlanner` a layout with a **known** partition under the shipped 16-byte-gap / 220-byte-span defaults — the offsets are the test, so moving one changes what the gate proves. | Address | Type | Seed | Role in the partition | |---|---|---|---| | `DB1.DBW300` | u16 | `51001` | cluster A — merges with the four below into ONE 300..320 span | | `DB1.DBW302` | i16 | `-21001` | cluster A (gap 0) | | `DB1.DBD304` | i32 | `305419896` | cluster A (gap 0) | | `DB1.DBX310.5` | bool | `true` | cluster A (gap 2) | | `DB1.DBD316` | f32 | `2.7182817` | cluster A (gap 5); seals the span at 20 bytes | | `DB1.DBW400` | u16 | `40201` | cluster B — 80 bytes on, so the gap budget forces a SECOND span | | `DB1.DBW402` | u16 | `40202` | cluster B's second member (keeps it off the `PrefersPerTagRead` demotion) | | `DB1.DBW500` | u16 | `60001` | isolated ⇒ demoted single-member span ⇒ multi-var leftover | | `DB1.DBW600` | i16 | `-32001` | isolated ⇒ multi-var leftover | | `MW10` | u16 | `4097` | multi-var leftover in a **different area** — a block read can't cross `(area, DB)`, multi-var can | Offsets `308`, `311` and `312` carry **poison** (`0xDEAD`, `0x5A`, `0xDEADBEEF`) inside the holes cluster A's span reads through. No tag maps to them; they are there so a mis-computed slice offset returns garbage instead of a zero that could match by luck. Every seed above is distinct and non-zero for the same reason. ## Known limitations From the `snap7.server.Server` docstring upstream: > "Legacy S7 server implementation. Emulates a Siemens S7 PLC for testing > and development purposes. [...] pure Python emulator implementation that > simulates PLC behaviour for protocol compliance testing rather than > full industrial-grade functionality." Not exercised here — needs a lab rig: - S7-1500 Optimized-DB symbolic access - PG / OP / S7-Basic session-type differentiation - PUT/GET-disabled-by-default enforcement See [`docs/drivers/S7-Test-Fixture.md`](../../../docs/drivers/S7-Test-Fixture.md) for the full coverage map. ## References - [python-snap7 GitHub](https://github.com/gijzelaerr/python-snap7) - [`docs/drivers/S7-Test-Fixture.md`](../../../docs/drivers/S7-Test-Fixture.md) — coverage map - [`docs/v2/dev-environment.md`](../../../docs/v2/dev-environment.md) §Docker fixtures