# FOCAS Driver Getting-started guide for the FANUC FOCAS2 driver. This is the short path — for the exhaustive per-node mapping read [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md), for the test-harness map read [FOCAS-Test-Fixture.md](FOCAS-Test-Fixture.md). ## What it talks to FANUC CNCs (0i-D / 0i-F / 0i-MF / 0i-TF / 16i / 30i / 31i / 32i / Power Motion i) over the proprietary FOCAS2 protocol on TCP port 8193. The wire is spoken directly by the pure-managed [`Focas.Wire`](https://github.com/Ladder99/focas-mock) client — no Fwlib64.dll, no P/Invoke, no out-of-process isolation needed. OtOpcUa is **read-only** against FOCAS; all reads go over the native wire protocol using the documented command IDs. Writes return `BadNotWritable` by design. > **Equipment tags are forced read-only (R2-11, migration note).** The equipment-tag parser > (`FocasEquipmentTagParser`) now hard-codes `Writable: false` regardless of any authored > `"writable": true` — previously such a tag advertised a writable node whose write always failed at > the wire with `BadNotWritable`; now it fails one step earlier at the driver seam (same family of Bad > status, no successful operation changes). The AdminUI FOCAS editor shows the Writable checkbox > disabled/unchecked, and the deploy gate warns when a config requests `writable:true`. Additionally, > equipment-tag references now run the same capability-matrix pre-flight authored tags get: a reference > whose address violates the device series' matrix fails to resolve (`BadNodeIdUnknown`) instead of > reaching the wire. Honour `writable` here once PMC writes ship in the wire client. > **PDU version (v3 / FANUC 30i/31i).** The wire client **accepts inbound PDU versions `{1, 3}`** > (`FocasWireProtocol`) while still emitting v1 on requests. Older controls + the docker mock answer > v1; modern controls (Makino Pro 5 / FANUC **31i-B**) answer v3. **Validated live against a real > 31i-B (`10.201.31.5`) 2026-06-25:** sysinfo, axis/spindle names, dynamic positions/feed/spindle, > program/mode, **macros**, **timers** (8-byte payload is little-endian {minute, msec}), **PMC range** > (request widened to the data-type byte width), **servo meters** (8-byte LOADELM stride + names from > the 0x0089 block), and **alarms** all read correctly. Several *decode* errors that survived that > validation (because they decode without failing — just wrongly) were later corrected from the > sister ignitionoee driver's live work on the same family of controls; see > [Wire decode corrections (2026-10)](#wire-decode-corrections-2026-10). The driver `cnc_rddynamic2` poll is 1-based. **`cnc_rdparam` is unsupported on this > control** — every request-framing variant returns `EW_FUNC` (likely a wrong v3 command id; needs a > reference FWLIB trace). The Test-Connect probe now runs a real wire session (initiate + cnc_statinfo) > instead of a bare TCP check. Full finding, captured wire bytes, validation results, and analysis: > [`docs/plans/2026-06-25-focas-pdu-v3-30i-b-support.md`](../plans/2026-06-25-focas-pdu-v3-30i-b-support.md) > + [`…-implementation-plan.md`](../plans/2026-06-25-focas-pdu-v3-implementation-plan.md). > Capture tools: `scripts/focas/capture-initiate.py`, `scripts/focas/capture-v3.py`. ## Project split | Project | Target | Role | |---------|--------|------| | `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS/` | net10.0 | In-process driver — hosts `WireFocasClient` which speaks FOCAS2 over TCP directly | Previous `Driver.FOCAS.Host` / `Driver.FOCAS.Shared` Tier-C split has been retired — the managed wire client removes the native-crash blast radius that justified the out-of-process service. ## Minimum deployment Register the driver instance in the main server's `appsettings.json`. No separate service, no DLL deployment, no shared-secret handshake: ```jsonc "Drivers": { "focas-cnc-1": { "Type": "FOCAS", "Config": { "Backend": "wire", "Devices": [ { "HostAddress": "focas://10.20.30.40:8193", "Series": "ThirtyOne_i" } ], "Tags": [ { "Name": "Mode", "DeviceHostAddress": "focas://10.20.30.40:8193", "Address": "PARAM:3402", "DataType": "Int32", "Writable": false }, { "Name": "SpndLoad", "DeviceHostAddress": "focas://10.20.30.40:8193", "Address": "MACRO:500", "DataType": "Float64", "Writable": false } ] } } } ``` The main server opens two TCP sockets per configured device and speaks the FOCAS2 binary protocol directly. No local privileged components, no platform bitness constraint — the driver runs on every host OtOpcUa runs on. ## Address forms | Form | Example | Meaning | |------|---------|---------| | `X0.0` / `R100` / `R100.3` | PMC bit or byte | Letter + number; optional `.bit` for bit access | | `PARAM:1815` / `PARAM:1815/0` | CNC parameter | Number + optional axis index | | `MACRO:500` | Custom macro variable | System / user macro variable number | | `FIXED:Identity/SeriesNumber` | Fixed-tree field | A path into the [fixed node tree](#fixed-node-tree) — read-only | PMC letters are series-gated by `FocasCapabilityMatrix.PmcLetters`; the 16i accepts `X Y F G R D` (F/G are the CNC-to-PMC / PMC-to-CNC handshake groups its ladders use, #265 — reads only, FOCAS stays read-only), while `M C E A K T` remain 0i-F / 30i-family. The first three name a location the driver asks the CNC for on demand. `FIXED:` does not: it names a field of the per-device fixed-tree snapshot the driver's own poll loop already maintains, so a `FIXED:` read issues no wire traffic. It exists because the fixed tree is the only part of the FOCAS surface with no address of its own, and v3 publishes nodes only for authored tags — so without a form to author, the fixed tree could not be published at all. **An address never carries the device.** A tag's device comes from its raw-tag Device row; an address that also named a host would be a second, conflicting routing channel. This is worth stating because it is exactly what went wrong in [#540](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/540): browse leaves advertised `{deviceHost}/{path}` as their reference, the browse-commit wrote that into the address, and every committed tag read `BadNodeIdUnknown` forever. Addresses are validated against the per-device `Series` at `InitializeAsync` — a config referencing a number outside the documented range for that series fails at load time with an error message naming the limit. See [`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) for the authoritative range table. (`FIXED:` paths have no numeric range to check; a path the machine does not expose reads `BadNodeIdUnknown`.) An address the parser cannot read is rejected **when you author it** — by the `/raw` tag modal, and by the deploy-time inspector for config arriving via CSV import or the API. It is not a warning you can deploy past into a driver that skips the tag at startup. ## Backend selection The driver picks its client from `Config.Backend`: | Value | Client | Use it for | |-------|--------|------------| | `wire` (default) | `WireFocasClient` | Production — pure-managed FOCAS2 over TCP | | `unimplemented` / `none` / `stub` | `UnimplementedFocasClientFactory` | Scaffolding a DriverInstance row before the CNC endpoint is reachable | **Fail-fast on `unimplemented` / `none` / `stub`:** a driver instance configured with any of these backends now **faults immediately at `InitializeAsync`** with a clear error message rather than reporting healthy and then failing on the first read/write/subscribe. The driver moves to `Faulted` state and the error is visible on the Admin UI driver-status panel. This is intentional — an operator who forgets to switch to `"wire"` before deploying to production sees a driver fault at startup, not a phantom-healthy driver that silently rejects every request. Previous backends (`fwlib`, `fwlib32`, `ipc`) have been retired along with `Driver.FOCAS.Host` and the Fwlib P/Invoke path. Configs that still reference them will throw at startup with a message pointing here. ## Capability surface | Capability | Wire path | Notes | |------------|-----------|-------| | `IReadable` | `ReadAsync` → `cnc_rdpmcrng` / `cnc_rdparam` / `cnc_rdmacro` | One TCP request/response per read; `Focas.Wire` serializes requests on socket 2 internally | | `IWritable` | returns `BadNotWritable` | OtOpcUa is read-only against FOCAS by design — no `cnc_wrparam` / `pmc_wrpmcrng` / `cnc_wrmacro` path is implemented, and none will be (policy: the stranded write/unlock backlog items #268–#271 are won't-do; a write path on a production CNC is a safety decision, not a feature gap) | | `ITagDiscovery` | `DiscoverAsync` | Emits `FOCAS/{device}/{tag}` folders per configured device | | `ISubscribable` | polled via shared `PollGroupEngine` | FOCAS has no push model — subscriptions turn into per-tag polling groups | | `IHostConnectivityProbe` | periodic `cnc_rdcncstat` | Probe cadence is `Probe.Interval`; transitions fire `OnHostStatusChanged` | | `IPerCallHostResolver` | lookup in `_tagsByName` | Each call routes to the device of the referenced tag | | `IAlarmSource` | polled `cnc_rdalmmsg2` via `FocasAlarmProjection` | Opt-in — set `AlarmProjection.Enabled=true`; diffs `(AlarmNumber, Type)` between ticks | Ack is a no-op — FANUC clears alarms on its own once the underlying condition resolves, so `AcknowledgeAsync` swallows the batch rather than surfacing `BadNotSupported`. ## Fixed node tree Enable a pre-defined hierarchy of CNC nodes populated automatically from `cnc_sysinfo` + `cnc_rdaxisname` + `cnc_rddynamic2` + related FWLIB calls, so operators get an out-of-the-box view of identity / axes / program / timers without declaring per-address tags. ```jsonc "Config": { "Devices": [ ... ], "Tags": [ ... ], "FixedTree": { "Enabled": true, "PollInterval": "00:00:00.250", // fast — per-axis dynamic reads "ProgramPollInterval": "00:00:01", // medium — program + mode changes "TimerPollInterval": "00:00:30" // slow — cumulative counters } } ``` `Enabled` defaults to **false** so an upgrade does not grow nodes on configs that never asked for them. You do not have to set it to use the tree: **authoring any `FIXED:` tag arms the poll loop by itself**, because committing those tags already says you want it. The flag remains the way to publish the tree without authoring anything (and the browser turns it on for the duration of a browse). ### Authoring fixed-tree tags Browse the device (`/raw` → device → **Browse device…**, or the tag modal's **Browse machine**) and commit the leaves you want. Each leaf carries its own `FIXED:` address, so the commit produces working tags with no editing. The manual composer next to the browser covers PMC / `PARAM:` / `MACRO:` only — fixed-tree paths are discovered from the machine, not composed from parts. Two caveats worth knowing before you browse: - **A CNC that reports duplicate sibling names is disambiguated automatically** (#548): every member of a collision set gets a 1-based occurrence suffix in slot order (`Axes/AA_1/`, `Axes/AA_2/`), each reading its own axis, while unique names stay bare (`Axes/Y/`). ⚠️ The Makino that motivated #548 does **not** in fact report duplicates — its axes are `AA6` and `AA7`, and the wire layer used to read only 2 of each 4-byte name record. Since the name-record fix those axes publish as `Axes/AA6/` and `Axes/AA7/`; tags committed against `Axes/AA_1/…` / `Axes/AA_2/…` on such a machine must be re-browsed and re-committed. The bare name of a duplicate set deliberately does not resolve: a tag authored against `Axes/AA/…` on such a machine reads `BadNodeIdUnknown` rather than one arbitrary axis's data. The suffix counts occurrences of the *same* name, so adding an unrelated axis never renames an existing pair — but if the collision-set membership itself changes (a third `AA` appears, or one of two is removed), the segments change on the next browse, and previously committed tags on the old segments read Bad until re-committed. The same rule covers spindles. - **Values are dated from the last answered poll, not from the read.** If a CNC stops answering, its fixed-tree values go `BadCommunicationError` rather than continuing to serve the last snapshot as `Good`; the budget is eight poll cadences, floored at 30 s. What gets populated (all under `FOCAS/{deviceHostAddress}/`, addressed as `FIXED:{subtree}/{field}`): | Subtree | Nodes | Source call | |---------|-------|-------------| | `Identity/` | `SeriesNumber`, `Version`, `MaxAxes`, `CncType`, `MtType`, `AxisCount` | `cnc_sysinfo` once at bootstrap | | `Axes/{name}/` | `AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`, `ServoLoad` — one folder per discovered axis | `cnc_rdaxisname` once + `cnc_rddynamic2` + `cnc_rdsvmeter` per tick | | `Axes/FeedRate/Actual`, `Axes/SpindleSpeed/Actual` | Current feed + spindle RPM | `cnc_rddynamic2` | | `Spindle/{name}/` | `Load` (Float64, % of rated load), `MotorSpeedPct` (Float64, % of maximum speed) — one folder per discovered spindle | `cnc_rdspdlname` once + `cnc_rdspmeter` type 0 + type 1 per tick | | `Program/` | `Name` (filename), `ONumber`, `Number`, `MainNumber`, `Sequence`, `BlockCount` — a field the CNC did not report (refused sub-read, payload without an O-number) reads `BadNoData`, never `0` | `cnc_exeprgname2` + `cnc_rdblkcount` + cached `cnc_rddynamic2` | | `OperationMode/` | `Mode` (int), `ModeText` ("AUTO", "MDI", "EDIT", …) | `cnc_rdopmode` | | `Status/` | `Auto`, `Run`, `Motion`, `Mstb`, `Emergency`, `Alarm`, `Edit`, `TmMode` (raw FANUC codes, Int32) + `RunText` ("RESET", "STOP", "HOLD", "START", "MSTR") — see [CNC status flags](#cnc-status-flags-status) | `cnc_statinfo` (polled on `ProgramPollInterval`) | | `Timers/` | `PowerOnSeconds`, `OperatingSeconds`, `CuttingSeconds`, `CycleSeconds` | `cnc_rdtimer` × 4 | ### CNC status flags (`Status/`) `cnc_statinfo` (the `ODBST` block) is exposed as read-only `FIXED:Status/` nodes (#257). Values are the control's raw codes, published verbatim as Int32 so a client sees exactly what the CNC reported: | Field | Codes | |---|---| | `Run` | 0 RESET, 1 STOP, 2 HOLD, 3 START, 4 MSTR (`RunText` is the label) | | `Auto` | operation mode (0 MDI, 1 MEM, 3 EDIT, 4 HND, 5 JOG, … — control-dependent) | | `Motion` | 0 none, 1 axis motion, 2 dwell | | `Mstb` | 0 idle, 1 executing an M/S/T/B function | | `Emergency` | 0 not, 1 emergency stop, 2 reset | | `Alarm` | 0 none, 1 alarm, … (battery-low etc. are control-dependent) | | `Edit`, `TmMode` | program-edit state; T/M mode | Author one the same way as any fixed-tree tag — `FIXED:Status/Run` (Int32), `FIXED:Status/RunText` (String). Like `Program/`, the subtree is gated on a bootstrap probe: a control that refuses `cnc_statinfo` gets no `Status/` nodes and the rest of the tree is unaffected. Reads are served from the poll snapshot, so they issue no wire traffic and go `BadCommunicationError` once the device has stopped answering. ### Per-series node suppression The driver probes each optional call once at bootstrap. If the target CNC returns `EW_FUNC` / `EW_NOOPT` / `EW_VERSION` on the wire, the corresponding subtree is **not emitted** — the operator doesn't see nodes that will only ever return `BadDeviceFailure`. Capability suppression covers `Spindle/`, `Program/` + `OperationMode/`, `Status/`, `Timers/`, and per-axis `ServoLoad` independently. Identity + `Axes/*` position reads (which every Fanuc CNC supports) are always emitted. Position values (`AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`) are published as `Float64` in engineering units. **Each `cnc_rddynamic2` position block carries its own scale** — `[i32 raw][u16 base][u16 exponent]`, value = `raw / base^exponent` (a real 31i-B reports base 10 / exponent 4: `2801574` → `280.1574` mm) — and the driver always applies it. A block that describes no usable position (the `0xFFFF` vacant-slot marker, a base other than 2 or 10, an exponent > 18) publishes `BadNoData` on that node alone. `PositionDecimalPlaces` (per device, default `0`) is now only the **fallback for a block that carries no scale** (a 4-byte payload, e.g. an older simulator): such a position is divided by `10^PositionDecimalPlaces`. Negative values are clamped to `0`. ```jsonc "Devices": [ { "HostAddress": "focas://10.20.30.40:8193", "Series": "ThirtyOne_i", "PositionDecimalPlaces": 3 // only used if the CNC's blocks carry no scale } ] ``` There is no `cnc_getfigure` read: the `0x00D3` command the driver used to send is not a FOCAS wire command (a real 31i-B refuses it with `rc=1`), so on hardware every axis had silently fallen back to `PositionDecimalPlaces` and published raw counts. **Still hand-authored**: `PARAM:6711`, `MACRO:500`, `R100` etc. — specific numbers whose meaning is MTB-specific, and which no browse can discover. Those go under the device folder alongside the fixed subtree. ### Parts count (`PARAM:6711`) There is deliberately **no** dedicated parts-count node (#258): the count is an ordinary CNC parameter, so it is already readable as a hand-authored `PARAM:` tag (Int32), and a fixed `Parts/` subtree would hard-code parameter numbers that are control- and MTB-specific. On the standard FANUC 0i / 16i / 30i parameter map: | Address | Parameter | Meaning | |---|---|---| | `PARAM:6711` | No. 6711 | Number of parts machined (resets with the operator's clear) | | `PARAM:6712` | No. 6712 | Total number of parts machined (cumulative) | | `PARAM:6713` | No. 6713 | Number of parts required (the target) | The count-up trigger (which M code or cycle end increments it) is set by No. 6710 and bit 0 of No. 6700, so confirm in the machine's parameter manual that the counter is actually enabled and that 6711–6713 mean what the MTB says they mean before relying on them. Cycle time per part is not provided; the `Timers/` subtree exposes `CycleSeconds` and a client can difference it across a `PARAM:6711` change. ## PMC range coalescing A poll batch that reads several nearby PMC tags used to issue one `pmc_rdpmcrng` per tag. The driver now merges tags of the same PMC letter and width that sit close together into **one** range read and slices each tag's value out of the result (#266). Single, isolated PMC tags — the common "one tag per area" case — are read exactly as before. ```jsonc "PmcCoalesce": { "Enabled": true, // default "MaxSpanBytes": 128, // hard cap on one merged range "MaxGapBytes": 8 // bytes nobody asked for tolerated between two merged tags; 0 = only strictly adjacent } ``` Rules worth knowing: - Tags merge only within the same letter and width class (Bit and Byte are one class; Word, Long, Float, Double are separate). A multi-byte tag joins a range only when its offset from the range start is a multiple of its width, because the CNC splits a range into width-sized slots from the start. - **Spare gap bytes must be valid PMC addresses.** A gap that crosses a hole in the CNC's PMC map makes the CNC refuse the whole range. That is handled, not fatal: a refused range is remembered per device and its tags are read **individually**, each with its own true status (a refusal is never stamped onto healthy members). If that happens routinely, lower `MaxGapBytes` (0 disables gap-spanning entirely) or set `Enabled` to `false`. - A transport failure or timeout on the merged read fails every member with `BadCommunicationError` and does **not** retry per tag — the link is down, so per-tag retries would only multiply timeouts. - Read-only: this changes `pmc_rdpmcrng` reads only; nothing here can write. The config key lives in the driver `Config` JSON. The AdminUI typed form does not yet surface it (an unknown key edited through that form is dropped), so set it in the raw config. ## Alarm projection Alarm surfacing is **disabled by default** because the polling cost is wasted on sites that don't consume CNC alarms. Opt in per driver instance: ```jsonc "Config": { "Devices": [ ... ], "Tags": [ ... ], "AlarmProjection": { "Enabled": true, "PollInterval": "00:00:02" } } ``` Every alarm transition fires `OnAlarmEvent` with: - `SourceNodeId` = the device host address (FOCAS has no per-node alarm model; the CNC exposes a single flat active-alarm list per session) - `ConditionId` = `"{host}#{Type}:{AlarmNumber}"` - `AlarmType` = projected from FANUC's `ALM_TYPE_*` (e.g. `Overtravel`, `Servo`, `Parameter`, `MacroAlarm`) - `Severity` = Overtravel / Servo / PulseCode → `Critical`; Parameter / Macro → `Medium`; everything else → `High` Cleared alarms fire a second event with `" (cleared)"` appended to the message so downstream consumers can ignore the clear if they only care about raises. ## Handle recycling FANUC CNCs have a finite FWLIB handle pool (~5–10 concurrent connections) and certain series have documented handle-leak bugs that manifest after long uptime. The driver can proactively close + reopen each device's session on a cadence to release its slot back to the pool: ```jsonc "Config": { "Devices": [ ... ], "HandleRecycle": { "Enabled": true, "Interval": "01:00:00" } } ``` Disabled by default — a healthy CNC + driver doesn't need it. Enable when field experience shows handle exhaustion. Typical tuning: 30 min for sites running multiple OtOpcUa instances against the same CNC (they share the pool); 6 h for a single-client deployment. Reads / writes during recycle simply wait for the reconnect rather than failing — worst case, an operator sees a brief read latency spike once per cadence. ## Testing - **Unit tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests/` cover the driver surface via `FakeFocasClient`. Includes the alarm-projection raise / clear diffing tests. - **Integration tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.IntegrationTests/` hold the Docker simulator scaffold (`OTOPCUA_FOCAS_SIM_ENDPOINT=host:port`; they skip when it is absent; `Series/WireBackendStatusAndPmcTests` covers `Status/` and PMC coalescing against the mock's `statinfo` and `pmc` state); see [`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md) for what the simulator emits vs. real CNC behaviour. - **E2E script** — `scripts/e2e/test-focas.ps1` stages Host + Proxy + a real CNC (or the simulator) and exercises connect → read → write → subscribe round-trips. See [`docs/drivers/FOCAS-Test-Fixture.md`](FOCAS-Test-Fixture.md) for the coverage map. ## Troubleshooting | Symptom | Likely cause | Fix | |---------|--------------|-----| | Driver faults immediately at startup with "unimplemented" in the error | `Backend` is `"unimplemented"` / `"none"` / `"stub"` | Change `Backend` to `"wire"` and supply the real CNC endpoint in `Devices[]` | | `BadCommunicationError` on every read | CNC unreachable on TCP:8193 | Check firewall / LAN reachability; FOCAS Ethernet option must be licensed on the CNC side | | Every read returns `BadNotWritable` on writes | Expected — OtOpcUa is read-only against FOCAS | If you actually need writes, open a feature request — the driver's managed wire client doesn't expose the write commands | | `BadOutOfRange` on reads for a macro/parameter | Config address outside the declared `Series` range | Check `docs/v2/focas-version-matrix.md` — either fix the address or widen the `Series` | | Alarm events never fire | `AlarmProjection.Enabled` left at default (false) | Set it to `true` in the driver config | | Axis position values seem 1000× too large | The CNC's position blocks carry no scale (older control / simulator) and `PositionDecimalPlaces` is not set | Add `"PositionDecimalPlaces": 3` (or the MTB-specific value) to the device entry in `Devices[]`. A real 30i/31i carries the scale in each block and needs no setting | | A fixed-tree node or `MACRO:` tag reads `BadNoData` | The CNC answered but described no value — a vacant macro variable, an undescribable position/meter record, a program field it did not report | Check the address on the control; this is the control's answer, not a comms fault | | An integer-typed `MACRO:` tag reads `BadTypeMismatch` | The macro holds a fractional value (e.g. `148.5`) | Author the tag as `Float64`, or point it at a whole-valued variable — a fraction is never truncated into an integer tag | ## Wire decode corrections (2026-10) Each of these decoded without ever failing — just wrongly — so live validation that only checked "the read succeeds" passed them. All were found by the sister **ignitionoee** FOCAS driver against a real Makino 31i-B (Z-34184, series G431) and ported here with its captured payloads as test fixtures (`tests/.../Driver.FOCAS.Tests/Fixtures/v3/`). Client-visible changes are marked ⚠️. | What | Before | Now | |------|--------|-----| | `cnc_rdmacro` decimal | read at payload offset 4 — a constant `10` length field — so `#500 = 1.0` published `0.01` | `dec_val` at offset 6; `mantissa / 10^dec`. Vacant variable → `BadNoData`; fractional value on an integer tag → `BadTypeMismatch`; integer tags receive the exact whole value | | Axis positions | scaled by `cnc_getfigure` (0x00D3), which does not exist — on hardware: raw counts | scaled by each block's own `base^exponent`; undescribable block → `BadNoData` | | Axis / spindle names | first 2 of 4 record bytes — `AA6`/`AA7` collapsed to `AA` | whole record up to the first NUL (residue after it discarded) — ⚠️ `Axes/AA_1`→`Axes/AA6` on such a machine | | `ServoLoad` | `value / 10^base` (offset 4 is the base, 10) — always ~0 | `value / base^exponent`, a direct percentage | | `Spindle/{n}/Load` | raw meter count, Int32 (`9155`) | ⚠️ Float64 % of rated load (`55.9`): the meter is a 1/16384 fraction of full scale | | `Spindle/{n}/MaxRpm` | the type-1 meter read once at bootstrap and served as a "max RPM" | ⚠️ **renamed `MotorSpeedPct`**, Float64 % of maximum speed, polled every tick | | Program `ONumber` / `Name` / `BlockCount` / `Mode` | defaulted to `0` / `""` when not reported (Mode `0` = MDI) | `BadNoData` | Not ported (and why): the ignitionoee `RunState` run-word decode and fault debounce (this driver publishes no run-state — `cnc_statinfo` is used only as the connectivity probe); `cnc_rdparam3` (0x008D) and its echo guard (this driver never sends 0x008D — the real 31i-B answers it with 264-byte records that are not a parameter read); the IODBPSD-offset and Fanuc-real `FLOAT` re-interpretation of `cnc_rdparam` (no successful `cnc_rdparam` capture exists on either side — the reference 31i-B refuses it with `EW_FUNC`, which already reads `BadNotSupported` here); and the all-axes multi-block `cnc_rddynamic2` batching (a latency optimisation, not a correctness fix). ## Further reading - [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md) — full OPC UA node mapping, pre-defined tag set, per-API notes - [`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) — per-series macro / parameter / PMC range table - [`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md) — captured FOCAS2 wire semantics (magic prefix, handshake, command-id table) - [upstream `Focas.Wire`](https://github.com/Ladder99/focas-mock/tree/main/dotnet/Focas.Wire) — the managed client implementation OtOpcUa consumes as a NuGet dependency