namespace ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests.S7_1500;
///
/// Driver-side configuration matching what Docker/profiles/s7_1500.json seeds
/// into the simulator's DB1 + MB areas. Tag names here become the full references
/// the smoke tests read/write against; addresses map 1:1 to the JSON profile's
/// seed offsets so a seed drift in the JSON surfaces as a driver-side read
/// mismatch, not a mystery test failure.
///
public static class S7_1500Profile
{
public const string ProbeTag = "ProbeProbeWord";
public const int ProbeSeedValue = 4242;
public const string SmokeI16Tag = "SmokeI16";
public const short SmokeI16SeedValue = -12345;
public const string SmokeI32Tag = "SmokeI32";
public const int SmokeI32SeedValue = 1234567890;
public const string SmokeF32Tag = "SmokeF32";
public const float SmokeF32SeedValue = 3.14159f;
public const string SmokeBoolTag = "SmokeBool";
public const string WriteScratchTag = "WriteScratch";
/// Builds the S7 driver options for the S7-1500 integration tests.
/// The hostname or IP address of the S7 PLC.
/// The port number for the S7 PLC connection.
public static S7DriverOptions BuildOptions(string host, int port) => new()
{
Host = host,
Port = port,
CpuType = S7CpuType.S71500,
Rack = 0,
Slot = 0,
Timeout = TimeSpan.FromSeconds(5),
// Disable the probe loop — the integration tests run their own reads +
// a background probe would race with them for the S7netplus mailbox
// gate, injecting flakiness that has nothing to do with the code
// under test.
Probe = new S7ProbeOptions { Enabled = false },
Tags =
[
new S7TagDefinition(ProbeTag, "DB1.DBW0", S7DataType.UInt16),
new S7TagDefinition(SmokeI16Tag, "DB1.DBW10", S7DataType.Int16),
new S7TagDefinition(SmokeI32Tag, "DB1.DBD20", S7DataType.Int32),
new S7TagDefinition(SmokeF32Tag, "DB1.DBD30", S7DataType.Float32),
new S7TagDefinition(SmokeBoolTag, "DB1.DBX50.3", S7DataType.Bool),
new S7TagDefinition(WriteScratchTag, "DB1.DBW100", S7DataType.UInt16),
],
};
}