# Scope: Equipment-Namespace Materialization in the Live Deploy Path > **STATUS UPDATE 2026-06-07 — WS-1/2/4 (structure) and WS-3a (VirtualTag live values) are DONE.** > The structure milestone shipped on `master` (`febe462..9a67ebc`). **WS-3a — live values via VirtualTags** > shipped on branch `feat/equipment-namespace-live-values` (plan: > [`2026-06-07-equipment-namespace-live-values.md`](2026-06-07-equipment-namespace-live-values.md)). > Verified live in docker-dev: galaxy mirror **396/396 Good**, and the company-shape Equipment namespace > carries **live Good values** via VirtualTags — every company signal backed by a real galaxy source > (396 of 1036; the other 640 cite synthetic refs the company UNS model invented beyond the 396 real > galaxy attributes). Restart-safe (bootstrap restore re-serves Good, no re-deploy). WS-3b (OpcUaClient > driver route) was **not** taken (the VirtualTag route was chosen). WS-5 (tests) done throughout. **Status:** WS-1/2/4 + WS-3a DONE (2026-06-07); WS-3b not pursued **Date:** 2026-06-06 **Author:** investigation while building the Northwind UNS overlay (see `scadaproj/otopcua-uns-loader/`) **Depends on:** the driver value-streaming fixes already on `master` (`c1ce583`, `b1b3f3f`) --- ## 1. One-paragraph summary OtOpcUa can build a **SystemPlatform** namespace (the Galaxy mirror) into the live OPC UA address space with streaming values, but it **cannot do the same for an `Equipment`-kind namespace**. The canonical UNS (`Enterprise/Site/Area/Line/Equipment/Signal`) that an Equipment namespace represents only ever materialises its **skeleton** (Area/Line/Equipment *folders*); the **signals under equipment** (`Tag`, `VirtualTag`, `ScriptedAlarm` rows) never appear, because the component that turns those rows into OPC UA variables — `EquipmentNodeWalker` — is **fully built and unit-tested but never invoked in production**, and the live rebuild path doesn't carry the data it needs. This document scopes the work to finish that pipeline. --- ## 2. What works vs. what doesn't (verified 2026-06-06) **Works — SystemPlatform / Galaxy mirror (reference implementation):** A deploy materialises one folder per Galaxy object and one variable per `Tag` row, and the driver streams live values into them. Verified live: 396 tags across 40 machines, all `Good`, on `opc.tcp://localhost:4840`. Path: `OpcUaPublishActor.HandleRebuild` → `Phase7Applier.MaterialiseHierarchy` + `Phase7Applier.MaterialiseGalaxyTags`, and values via the `DriverHostActor` SubscribeBulk pass (`b1b3f3f`). **Doesn't work — Equipment namespace:** Deploying an `Equipment` namespace + a `UnsArea`/`UnsLine`/`Equipment` + one `VirtualTag` produced: ``` Phase7Applier: hierarchy materialised (areas=1, lines=1, equipment=1) ← folders only ``` …and the equipment node had **zero child variables** — the VirtualTag never materialised. There was no equipment-tag/virtual-tag log line at all. --- ## 3. Root cause (precise) Three gaps, in order of how fundamental they are: ### 3.1 `EquipmentNodeWalker` is built + tested but never wired (the core gap) - `src/Core/ZB.MOM.WW.OtOpcUa.Core/OpcUa/EquipmentNodeWalker.cs` — `Walk(IAddressSpaceBuilder, EquipmentNamespaceContent)` materialises every `Equipment` row as a folder and every Equipment-bound `Tag` / `VirtualTag` / `ScriptedAlarm` as a variable (NodeId = `DriverAttributeInfo.FullName`, i.e. the tag's `TagConfig.FullName`; VirtualTag uses its `VirtualTagId`). - **The only call sites are in `tests/Core/.../EquipmentNodeWalkerTests.cs`.** Nothing in `src` ever calls `EquipmentNodeWalker.Walk`, and nothing builds its input record `EquipmentNamespaceContent` (the record exists; no producer exists). - The live rebuild — `src/Server/.../Runtime/OpcUa/OpcUaPublishActor.cs:HandleRebuild` — calls `MaterialiseHierarchy` (the Area/Line/Equipment *folders*) and `MaterialiseGalaxyTags` (SystemPlatform only). It never calls `EquipmentNodeWalker`. - `OtOpcUaNodeManager` references `EquipmentNodeWalker` only in a header comment — not in `CreateAddressSpace`. ### 3.2 The deployment composition/artifact drops equipment signals - `Phase7CompositionResult` (`src/Server/.../OpcUaServer/Phase7Composer.cs`) carries `UnsAreas`, `UnsLines`, `EquipmentNodes` *(EquipmentId, DisplayName, UnsLineId — no tags)*, `DriverInstancePlans`, `ScriptedAlarmPlans`, `GalaxyTags`. **There is no equipment-tag or virtual-tag list.** - `DeploymentArtifact.ParseComposition` (`src/Server/.../Runtime/Drivers/DeploymentArtifact.cs`) reads the artifact's `Tags` array but **`BuildGalaxyTagPlans` explicitly skips any tag with a non-null `EquipmentId`** (line ~176). So even though equipment tags are serialised into the artifact, the composition the node consumes throws them away. So even if `EquipmentNodeWalker` were wired into `HandleRebuild`, it would have no equipment-tag data to walk. ### 3.3 No value source for Equipment-namespace signals Equipment signals can be valued two ways; **neither is currently wired**: - **Driver-sourced `Tag` (e.g. an OPC UA Client remap of the Galaxy mirror):** the **OpcUaClient driver has no factory registration** — `DriverFactoryBootstrap.Register` (`src/Server/.../Host/Drivers/DriverFactoryBootstrap.cs`) wires AbCip/AbLegacy/FOCAS/Galaxy/ Modbus/S7/TwinCAT but **not OpcUaClient**, so an `OpcUaClient` `DriverInstance` silently stubs → no values. (The driver itself, `IDriver,ITagDiscovery,IReadable,IWritable,ISubscribable,…`, exists and is otherwise complete; only the factory `Register` is missing.) - **`VirtualTag` (script mirrors a live tag):** the `DependencyMuxActor` + a real `IVirtualTagEvaluator` are registered (`Runtime/ServiceCollectionExtensions.cs:100`, `Host/Program.cs:102`), and driver values now reach the mux (`DriverHostActor.ForwardToMux`, `b1b3f3f`). But `VirtualTagContext.GetTag` reads from a per-evaluation cache fed by an `ITagUpstreamSource`, and **no concrete `ITagUpstreamSource` is registered in the Host** — and it is unverified whether a `VirtualTag` in an `Equipment` namespace can resolve a tag that lives in the `SystemPlatform` namespace (cross-namespace `ctx.GetTag("/TestMachine_001/…")`). --- ## 4. Goal / acceptance criteria A deploy that includes an `Equipment`-kind namespace results in, on `opc.tcp://…:4840`: 1. **Structure:** browsable `…////` for every `UnsArea`/`UnsLine`/ `Equipment`/`Tag`(+`VirtualTag`,`ScriptedAlarm`) row — folders **browse-named by their friendly `Name`**, not their logical Id (see §6.4). 2. **Values:** each signal carries a live `Good` value (driver-sourced and/or VirtualTag-derived). 3. **Reload-safe:** survives a node restart with no re-deploy (must run on the `RestoreApplied` bootstrap path added in `b1b3f3f`, not just on a fresh apply). 4. **Verifiable headlessly:** the `scadaproj/otopcua-uns-loader` tool's `verify` passes against the company-shape namespace (extend it to browse the Equipment tree). --- ## 5. Workstreams ### WS-1 — Carry equipment signals through the composition (foundational) Extend `Phase7CompositionResult` with equipment `Tag`/`VirtualTag`/`ScriptedAlarm` plans (or reuse `EquipmentNamespaceContent`), populate them in `Phase7Composer.Compose`, serialise them in the deployment artifact, and parse them in `DeploymentArtifact.ParseComposition` (stop discarding `EquipmentId != null` tags). **Risk: medium** (touches composer + artifact format + planner; needs a format-compat story for already-sealed artifacts). **Effort: ~1–2 days.** ### WS-2 — Materialise equipment signals in the live rebuild (wire the existing component) In `OpcUaPublishActor.HandleRebuild`, after `MaterialiseHierarchy`, build `EquipmentNamespaceContent` from the composition and call the already-tested `EquipmentNodeWalker.Walk`. Make it idempotent and diff-aware to match the existing Galaxy-tag pass. **Risk: low–medium** (component is tested; this is wiring + an idempotency pass). **Effort: ~0.5–1 day.** ### WS-3 — Value path (pick one or both; see §6.1) - **3a VirtualTag route:** register a concrete `ITagUpstreamSource` in the Host that bridges the `DependencyMuxActor`'s tag values into the VirtualTag read-cache; confirm/enable cross-namespace `ctx.GetTag` resolution (Equipment VirtualTag reading a SystemPlatform mirror tag) and the dependency-graph re-evaluation trigger. **Risk: high** (cross-namespace resolution + dependency tracking are unproven end-to-end). **Effort: ~2–3 days.** - **3b OpcUaClient route:** write+register `OpcUaClientDriverFactoryExtensions.Register` and add it to `DriverFactoryBootstrap.Register`; extend the SubscribeBulk pass to also subscribe Equipment-namespace `Tag` refs (`TagConfig.FullName`; NodeId == FullName, so the existing `ForwardToMux` value routing already applies — a ~30-line generalisation prototyped and reverted this session); decide the self-referential endpoint topology (a MAIN driver node OPC-UA-clienting into its own `:4840` Galaxy mirror, vs a second cluster). **Risk: high** (unfinished driver + self-loop topology). **Effort: ~2–4 days.** ### WS-4 — Browse-name fix (cosmetic but required for a usable shape) Today the UNS folder browse name is the logical **Id** (observed `nw-area-filling`), not the friendly `Name` (`filling`). Confirm whether `Phase7Applier.MaterialiseHierarchy` / `EquipmentNode.DisplayName` should use `UnsArea.Name`/`UnsLine.Name`/`Equipment.Name` for the BrowseName (keeping the Id as the NodeId). **Risk: low.** **Effort: ~0.5 day.** ### WS-5 — Tests + headless verification Unit: composer carries equipment signals; `HandleRebuild` materialises them; round-trip artifact parse. Integration: a docker-dev deploy of a small Equipment namespace browses + reads `Good`. Extend `otopcua-uns-loader verify` to assert the Equipment tree. **Effort: ~1 day.** --- ## 6. Design decisions / open questions 1. **VirtualTag (3a) vs OpcUaClient (3b) for live values.** VirtualTags reuse the live Galaxy mirror in-process (no second OPC UA session) but lean on unproven cross-namespace script resolution; OpcUaClient is the documented "remote-equipment → UNS" pattern but needs an unfinished driver factory and a self-referential session. **Recommendation:** prototype 3a first (smaller surface, no new driver), fall back to 3b if cross-namespace resolution proves intractable. A structure-only milestone (WS-1/2/4, no values) is independently shippable. 2. **Cross-namespace `ctx.GetTag`.** Does an Equipment-namespace VirtualTag resolve a SystemPlatform Galaxy tag by browse path (`/TestMachine_001/TestChangingInt`) or by reference (`TestMachine_001.TestChangingInt`)? Determines the script-authoring contract. Must be settled before WS-3a. 3. **Artifact format compatibility.** Adding equipment signals to the artifact changes its shape; ensure older sealed artifacts still parse (the parser is tolerant today — keep it so). 4. **Browse-name source** (WS-4) — `Name` vs `Id`. Picking `Name` makes the company shape readable; confirm nothing keys off the Id-as-BrowseName. --- ## 7. Recommended sequencing 1. **WS-1 + WS-2 + WS-4 (structure-only):** Equipment namespaces browse the real `…/area/line/equipment/signal` shape with `BadWaitingForInitialData` leaves. Independently shippable; de-risks the composition/materialisation half. 2. **WS-3a (VirtualTag values):** lights the structure up by mirroring the live Galaxy tags. 3. **WS-3b (OpcUaClient driver):** only if a true remote-equipment driver path is wanted beyond the Galaxy mirror. 4. **WS-5** throughout. **Rough total:** structure-only ≈ 2–3.5 days; +VirtualTag values ≈ +2–3 days. ## 8. Out of scope - Authoring the company UNS rows (the `scadaproj/otopcua-uns-loader` tool already generates them from `company-uns.json`). - Any change to the SystemPlatform/Galaxy path, which works. - The AdminUI UNS editor. ## 9. Key references - Works (reference): `OpcUaPublishActor.HandleRebuild` + `Phase7Applier.MaterialiseGalaxyTags`; SubscribeBulk in `DriverHostActor` (commits `c1ce583`, `b1b3f3f`). - Built-but-unwired: `Core/OpcUa/EquipmentNodeWalker.cs` (+ `EquipmentNamespaceContent`), tested only by `EquipmentNodeWalkerTests.cs`. - Composition gap: `OpcUaServer/Phase7Composer.cs` (`Phase7CompositionResult`), `Runtime/Drivers/DeploymentArtifact.cs` (`BuildGalaxyTagPlans` skips `EquipmentId != null`). - Value gaps: `Host/Drivers/DriverFactoryBootstrap.cs` (no OpcUaClient registration); `Core.VirtualTags/ITagUpstreamSource.cs` (no Host registration found). - The consuming tool + the company model: `scadaproj/otopcua-uns-loader/`, `scadaproj/company-uns.json`.