# lmxopcua#800 / #883: ScriptWorker isolation re-run on windev (2026-11-12) **Result: the repository's `Install-ScriptWorkerIsolation.ps1` (fixed for #883) passes on both Windows PowerShell 5.1 and PowerShell 7 against a real `OtOpcUaHost` service.** This re-runs only the step that failed in [`../2026-11-12-windev/RESULTS.md`](../2026-11-12-windev/RESULTS.md) (step 3, ScriptWorker). Steps 1, 2, 4 and 5 are in that record. ## What was run - **Node:** windev (`DESKTOP-6JL3KKO`), now 16 vCPUs, elevated SSH session, PowerShell 7.6.10 and Windows PowerShell 5.1.19041. Timings are not comparable to the first run. - **Candidate:** master `da948e5f` (SDK 2: `Opc.Ua.Core` 2.0.1.2), self-contained win-x64, built on macOS. `OtOpcUa.Host.exe` `934a749f446c724579806cbbf36d7a12690a0a5bb9f97b5e39b9502a43c9087a`; `script-worker\ZB.MOM.WW.OtOpcUa.ScriptWorker.exe` `c2a2a56d3d91916daba72bd4d69e3ded5cad309121ae9ca00d4e8a3fe9aaae12`. Manifests: `manifest-candidate-*.txt`, matched file-for-file on the box (probe, seeder and baseline CLI matched the first run's manifests). The install scripts are the repo tree's. - **Install:** `Install-Services.ps1 -Roles driver -ServiceAccount 'NT SERVICE\OtOpcUaHost'` from the candidate tree (`Prepare -PrepareFrom candidate`), task-only ports 18800 / 14841 / 18801, anonymous and auto-accept off, Sign + SignAndEncrypt. - **Starts:** c0 (creates PKI/LocalDb), c1 (seeded, no isolation), c3, c4, c5 (isolation on, `Scripting__Runner=OutOfProcess`). The application certificate was `A5A8238BB21874C381EA46294F2D21AF072EF1C0` at every start. ## Installer cycles (`isolation-install-sN.json`, `isolation-uninstall-sN.json`) | Label | Script version | Apply host | Re-apply | Second re-apply | Uninstall | Second uninstall | |---|---|---|---|---|---|---| | s1 | #883 patch only | pwsh 7 | 5.1: 7/7 unchanged | pwsh: 7/7 unchanged | pwsh: 6 changed | 5.1: 6/6 unchanged | | s2 | #883 patch only | **5.1** | pwsh: **AnchorService changed** | 5.1: 7/7 unchanged | 5.1: 6 changed | pwsh: 6/6 unchanged | | s3 | **final** | **5.1** | pwsh: 7/7 unchanged | 5.1: 7/7 unchanged | 5.1: 6 changed | pwsh: 6/6 unchanged | | s4 | **final** | pwsh 7 | 5.1: 7/7 unchanged | pwsh: 7/7 unchanged | pwsh: 6 changed | 5.1: 6/6 unchanged | `-WhatIf` on both hosts exited 0 and changed nothing in every cycle. **Second defect found by s2 (fixed in the same commit).** The #883 patch made both hosts work, but an apply from Windows PowerShell 5.1 was not idempotent: `AnchorService` reported `changed` on every re-run. Windows PowerShell 5.1 passes the literal quotes in `binPath= "C:\...\ZB.MOM.WW.OtOpcUa.ScriptWorker.exe"` to `sc.exe` with legacy quoting, which stored the path unquoted (a path with spaces, such as `C:\Program Files\OtOpcUa`, is worse). The step compares the quoted form, so it rewrote the service each time. The installer now runs `sc.exe create|config` through `Invoke-OtOpcUaSc`, which builds the command line explicitly and behaves the same on both hosts. s3/s4 are with the fix, and `Test-ScriptWorkerIsolation.Windows.ps1` asserts the stored path (`windows-test-results.txt`). ## State after apply (s1, #794 step 4) - `OtOpcUaScriptWorker`: START_TYPE 4 DISABLED, SERVICE_START_NAME `NT SERVICE\OtOpcUaScriptWorker`, SID `S-1-5-80-1846135827-3903057317-1998105452-3938448374-3023753135` (matches #794). - ``: protected, SYSTEM, Administrators and `NT SERVICE\OtOpcUaHost` full control, no Users; `\pe` adds `NT SERVICE\OtOpcUaScriptWorker:(OI)(CI)(M)`. - Install root: `NT SERVICE\OtOpcUaScriptWorker:(OI)(CI)(DENY)(S,RD)`; `script-worker\`: `(OI)(CI)(RX)`. - Firewall `OtOpcUa-ScriptWorker-BlockOutbound`: Outbound / Block / Any profile, program the worker exe. - Host service environment gained exactly `Scripting__Worker__Identity` and `Scripting__Worker__PeCacheDir` (plus the gate's `Scripting__Runner=OutOfProcess`); every other entry was kept. After uninstall the environment and the install-root ACL are back to their pre-install state. ## Runtime under the real service (`isolation-verify-c3/c4/c5.json`) | Start | Isolation applied by | Ready | ServiceLevel | Worker | Pipe, elevated admin | `script-runner` | Stop | Strict-peer/API-key matrix + CLIs | |---|---|---|---|---|---|---|---|---| | c3 | pwsh 7 (s1) | 15 s | 255 | 1 child of the host, owner `NT SERVICE\OtOpcUaHost`, `restricted=True`, 1 privilege | denied (`UnauthorizedAccessException`) | Healthy, PE cache on, 1 `pe\` entry | 1.8 s, exit 0, no worker left | 14 cases + 3 CLI reads pass | | c4 | 5.1 (s2) | 15 s | 255 | same | denied | same | 1.8 s | same | | c5 | 5.1 (s3, final script) | 15 s | 255 | same | denied | same | 1.8 s | same | - The window-station grant works under a real service session (coreclr loaded; no `ERROR_DLL_INIT_FAILED`). - The out-of-process virtual tag read 800 Good in the probe at every isolation start. - 0 occurrences of any task secret in the rolling logs, the selflog or the Application event log (`stop-*.json`); the evidence folder was scanned against every task secret before it was copied off (0 hits). - `compare-c0-c1-c3-c4-c5.json`: the certificate is identical at every start; c3, c4 and c5 have identical PKI digests and node environment digests (c0 -> c1 differ by the trust copies and the rejected-client entries; c3 onwards adds the isolation ACE and entries). - Not exercised: dropped-packet firewall logging (#794 step 5, QA only). ## Standalone Windows test `scripts/install/tests/Test-ScriptWorkerIsolation.Windows.ps1` (new for #883): apply, re-apply, uninstall twice against scratch names and a stand-in host service. It failed on 5.1 before the second fix and passes 24/24 on 5.1 and on pwsh 7 (`windows-test-results.txt`). ## Cleanup - The `OtOpcUaHost` service (`sc.exe delete`), the anchor, the firewall rule, `C:\OtOpcUa800` and the uploaded scripts are removed; `%LOCALAPPDATA%\OtOpcUaClient` is restored; firewall rule count 876; MxAccessGw Running with `:5130/health/ready` 200; OtOpcUaWonderwareHistorian untouched (Running). `Uninstall-Services.ps1` was not used. - **Residual:** the virtual-account profile `C:\Windows\ServiceProfiles\OtOpcUaHost` (`S-1-5-80-3928861625-3486739760-3962757976-1980707066-3667558059`) was already loaded when this run started (after the reboot) and is still loaded now that the service is gone: `Remove-CimInstance` retried for about 2 minutes fails with "being used by another process" and `reg unload` is refused. It cannot be removed without a reboot of windev.