Document the shared OPC UA endpoint rewrite (driver + AdminUI browser) #814
Reference in New Issue
Block a user
Delete Branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
#806 moved the advertised-URL host/port rewrite into OpcUaEndpointUrlRewriter (Driver.OpcUaClient.Contracts) + OpcUaEndpointSelection (Driver.OpcUaClient.Session), used by the runtime driver and the AdminUI browser. docs/plans/2026-05-28-driver-browsers-design.md and docs/drivers/OpcUaClient.md don't mention it.
Document that both keep the operator-configured host and port and the advertised path for opc.tcp, that certificate validation and policy/mode selection are unchanged, and how to run the NAT tests (see the NAT fixture follow-up).
Done on master (
88c05cc0).docs/drivers/OpcUaClient.md,docs/plans/2026-05-28-driver-browsers-design.mdanddocs/Client.CLI.mddocument the single shared rewriter (driver, AdminUI browser, CLI/UI): for opc.tcp the configured host+port win and the advertised path is kept; policy/mode selection and certificate validation are unchanged; how to run the NAT tests against the #813 fixture.