@@ -37,7 +37,7 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
private CancellationTokenSource? _probeCts;
|
||||
private readonly ModbusDriverOptions _options = options;
|
||||
private readonly Func<ModbusDriverOptions, IModbusTransport> _transportFactory =
|
||||
transportFactory ?? (o => new ModbusTcpTransport(o.Host, o.Port, o.Timeout));
|
||||
transportFactory ?? (o => new ModbusTcpTransport(o.Host, o.Port, o.Timeout, o.AutoReconnect));
|
||||
|
||||
private IModbusTransport? _transport;
|
||||
private DriverHealth _health = new(DriverState.Unknown, null, null);
|
||||
@@ -141,9 +141,16 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
results[i] = new DataValueSnapshot(value, 0u, now, now);
|
||||
_health = new DriverHealth(DriverState.Healthy, now, null);
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, MapModbusExceptionToStatus(mex.ExceptionCode), null, now);
|
||||
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, mex.Message);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, StatusBadInternalError, null, now);
|
||||
// Non-Modbus-layer failure: socket dropped, timeout, malformed response. Surface
|
||||
// as communication error so callers can distinguish it from tag-level faults.
|
||||
results[i] = new DataValueSnapshot(null, StatusBadCommunicationError, null, now);
|
||||
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, ex.Message);
|
||||
}
|
||||
}
|
||||
@@ -238,6 +245,10 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
await WriteOneAsync(transport, tag, w.Value, cancellationToken).ConfigureAwait(false);
|
||||
results[i] = new WriteResult(0u);
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
{
|
||||
results[i] = new WriteResult(MapModbusExceptionToStatus(mex.ExceptionCode));
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadInternalError);
|
||||
@@ -686,6 +697,31 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
private const uint StatusBadInternalError = 0x80020000u;
|
||||
private const uint StatusBadNodeIdUnknown = 0x80340000u;
|
||||
private const uint StatusBadNotWritable = 0x803B0000u;
|
||||
private const uint StatusBadOutOfRange = 0x803C0000u;
|
||||
private const uint StatusBadNotSupported = 0x803D0000u;
|
||||
private const uint StatusBadDeviceFailure = 0x80550000u;
|
||||
private const uint StatusBadCommunicationError = 0x80050000u;
|
||||
|
||||
/// <summary>
|
||||
/// Map a server-returned Modbus exception code to the most informative OPC UA
|
||||
/// StatusCode. Keeps the driver's outward-facing status surface aligned with what a
|
||||
/// Modbus engineer would expect when reading the spec: exception 02 (Illegal Data
|
||||
/// Address) surfaces as BadOutOfRange so clients can distinguish "tag wrong" from
|
||||
/// generic BadInternalError, exception 04 (Server Failure) as BadDeviceFailure so
|
||||
/// operators see a CPU-mode problem rather than a driver bug, etc. Per
|
||||
/// <c>docs/v2/dl205.md</c>, DL205/DL260 returns only codes 01-04 — no proprietary
|
||||
/// extensions.
|
||||
/// </summary>
|
||||
internal static uint MapModbusExceptionToStatus(byte exceptionCode) => exceptionCode switch
|
||||
{
|
||||
0x01 => StatusBadNotSupported, // Illegal Function — FC not in supported list
|
||||
0x02 => StatusBadOutOfRange, // Illegal Data Address — register outside mapped range
|
||||
0x03 => StatusBadOutOfRange, // Illegal Data Value — quantity over per-FC cap
|
||||
0x04 => StatusBadDeviceFailure, // Server Failure — CPU in PROGRAM mode during protected write
|
||||
0x05 or 0x06 => StatusBadDeviceFailure, // Acknowledge / Server Busy — long-running op / busy
|
||||
0x0A or 0x0B => StatusBadCommunicationError, // Gateway path unavailable / target failed to respond
|
||||
_ => StatusBadInternalError,
|
||||
};
|
||||
|
||||
public void Dispose() => DisposeAsync().AsTask().GetAwaiter().GetResult();
|
||||
public async ValueTask DisposeAsync()
|
||||
|
||||
@@ -45,6 +45,17 @@ public sealed class ModbusDriverOptions
|
||||
/// by shortening the tag's <c>StringLength</c> or splitting it into multiple tags).
|
||||
/// </summary>
|
||||
public ushort MaxRegistersPerWrite { get; init; } = 123;
|
||||
|
||||
/// <summary>
|
||||
/// When <c>true</c> (default) the built-in <see cref="ModbusTcpTransport"/> detects
|
||||
/// mid-transaction socket failures (<see cref="System.IO.EndOfStreamException"/>,
|
||||
/// <see cref="System.Net.Sockets.SocketException"/>) and transparently reconnects +
|
||||
/// retries the PDU exactly once. Required for DL205/DL260 because the H2-ECOM100
|
||||
/// does not send TCP keepalives — intermediate NAT / firewall devices silently close
|
||||
/// idle sockets and the first send after the drop would otherwise surface as a
|
||||
/// connection error to the caller even though the PLC is up.
|
||||
/// </summary>
|
||||
public bool AutoReconnect { get; init; } = true;
|
||||
}
|
||||
|
||||
public sealed class ModbusProbeOptions
|
||||
|
||||
@@ -8,22 +8,40 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
/// support concurrent transactions, but the single-flight model keeps the wire trace
|
||||
/// easy to diagnose and avoids interleaved-response correlation bugs.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// Survives mid-transaction socket drops: when a send/read fails with a socket-level
|
||||
/// error (<see cref="IOException"/>, <see cref="SocketException"/>, <see cref="EndOfStreamException"/>)
|
||||
/// the transport disposes the dead socket, reconnects, and retries the PDU exactly
|
||||
/// once. Deliberately limited to a single retry — further failures bubble up so the
|
||||
/// driver's health surface reflects the real state instead of masking a dead PLC.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// Why this matters for DL205/DL260: the AutomationDirect H2-ECOM100 does NOT send
|
||||
/// TCP keepalives per <c>docs/v2/dl205.md</c> §behavioral-oddities, so any NAT/firewall
|
||||
/// between the gateway and PLC can silently close an idle socket after 2-5 minutes.
|
||||
/// Also enables OS-level <c>SO_KEEPALIVE</c> so the driver's own side detects a stuck
|
||||
/// socket in reasonable time even when the application is mostly idle.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public sealed class ModbusTcpTransport : IModbusTransport
|
||||
{
|
||||
private readonly string _host;
|
||||
private readonly int _port;
|
||||
private readonly TimeSpan _timeout;
|
||||
private readonly bool _autoReconnect;
|
||||
private readonly SemaphoreSlim _gate = new(1, 1);
|
||||
private TcpClient? _client;
|
||||
private NetworkStream? _stream;
|
||||
private ushort _nextTx;
|
||||
private bool _disposed;
|
||||
|
||||
public ModbusTcpTransport(string host, int port, TimeSpan timeout)
|
||||
public ModbusTcpTransport(string host, int port, TimeSpan timeout, bool autoReconnect = true)
|
||||
{
|
||||
_host = host;
|
||||
_port = port;
|
||||
_timeout = timeout;
|
||||
_autoReconnect = autoReconnect;
|
||||
}
|
||||
|
||||
public async Task ConnectAsync(CancellationToken ct)
|
||||
@@ -39,12 +57,34 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
var target = ipv4 ?? (addresses.Length > 0 ? addresses[0] : System.Net.IPAddress.Loopback);
|
||||
|
||||
_client = new TcpClient(target.AddressFamily);
|
||||
EnableKeepAlive(_client);
|
||||
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
cts.CancelAfter(_timeout);
|
||||
await _client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
|
||||
_stream = _client.GetStream();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Enable SO_KEEPALIVE with aggressive probe timing. DL205/DL260 doesn't send keepalives
|
||||
/// itself; having the OS probe the socket every ~30s lets the driver notice a dead PLC
|
||||
/// or broken NAT path long before the default 2-hour Windows idle timeout fires.
|
||||
/// Non-fatal if the underlying OS rejects the option (some older Linux / container
|
||||
/// sandboxes don't expose the fine-grained timing levers — the driver still works,
|
||||
/// application-level probe still detects problems).
|
||||
/// </summary>
|
||||
private static void EnableKeepAlive(TcpClient client)
|
||||
{
|
||||
try
|
||||
{
|
||||
client.Client.SetSocketOption(SocketOptionLevel.Socket, SocketOptionName.KeepAlive, true);
|
||||
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveTime, 30);
|
||||
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveInterval, 10);
|
||||
client.Client.SetSocketOption(SocketOptionLevel.Tcp, SocketOptionName.TcpKeepAliveRetryCount, 3);
|
||||
}
|
||||
catch { /* best-effort; older OSes may not expose the granular knobs */ }
|
||||
}
|
||||
|
||||
public async Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_disposed) throw new ObjectDisposedException(nameof(ModbusTcpTransport));
|
||||
@@ -53,43 +93,18 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
await _gate.WaitAsync(ct).ConfigureAwait(false);
|
||||
try
|
||||
{
|
||||
var txId = ++_nextTx;
|
||||
|
||||
// MBAP: [TxId(2)][Proto=0(2)][Length(2)][UnitId(1)] + PDU
|
||||
var adu = new byte[7 + pdu.Length];
|
||||
adu[0] = (byte)(txId >> 8);
|
||||
adu[1] = (byte)(txId & 0xFF);
|
||||
// protocol id already zero
|
||||
var len = (ushort)(1 + pdu.Length); // unit id + pdu
|
||||
adu[4] = (byte)(len >> 8);
|
||||
adu[5] = (byte)(len & 0xFF);
|
||||
adu[6] = unitId;
|
||||
Buffer.BlockCopy(pdu, 0, adu, 7, pdu.Length);
|
||||
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
cts.CancelAfter(_timeout);
|
||||
await _stream.WriteAsync(adu.AsMemory(), cts.Token).ConfigureAwait(false);
|
||||
await _stream.FlushAsync(cts.Token).ConfigureAwait(false);
|
||||
|
||||
var header = new byte[7];
|
||||
await ReadExactlyAsync(_stream, header, cts.Token).ConfigureAwait(false);
|
||||
var respTxId = (ushort)((header[0] << 8) | header[1]);
|
||||
if (respTxId != txId)
|
||||
throw new InvalidDataException($"Modbus TxId mismatch: expected {txId} got {respTxId}");
|
||||
var respLen = (ushort)((header[4] << 8) | header[5]);
|
||||
if (respLen < 1) throw new InvalidDataException($"Modbus response length too small: {respLen}");
|
||||
var respPdu = new byte[respLen - 1];
|
||||
await ReadExactlyAsync(_stream, respPdu, cts.Token).ConfigureAwait(false);
|
||||
|
||||
// Exception PDU: function code has high bit set.
|
||||
if ((respPdu[0] & 0x80) != 0)
|
||||
try
|
||||
{
|
||||
var fc = (byte)(respPdu[0] & 0x7F);
|
||||
var ex = respPdu[1];
|
||||
throw new ModbusException(fc, ex, $"Modbus exception fc={fc} code={ex}");
|
||||
return await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
|
||||
}
|
||||
catch (Exception ex) when (_autoReconnect && IsSocketLevelFailure(ex))
|
||||
{
|
||||
// Mid-transaction drop: tear down the dead socket, reconnect, resend. Single
|
||||
// retry — if it fails again, let it propagate so health/status reflect reality.
|
||||
await TearDownAsync().ConfigureAwait(false);
|
||||
await ConnectAsync(ct).ConfigureAwait(false);
|
||||
return await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
|
||||
}
|
||||
|
||||
return respPdu;
|
||||
}
|
||||
finally
|
||||
{
|
||||
@@ -97,6 +112,68 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
}
|
||||
}
|
||||
|
||||
private async Task<byte[]> SendOnceAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_stream is null) throw new InvalidOperationException("Transport not connected");
|
||||
var txId = ++_nextTx;
|
||||
|
||||
// MBAP: [TxId(2)][Proto=0(2)][Length(2)][UnitId(1)] + PDU
|
||||
var adu = new byte[7 + pdu.Length];
|
||||
adu[0] = (byte)(txId >> 8);
|
||||
adu[1] = (byte)(txId & 0xFF);
|
||||
// protocol id already zero
|
||||
var len = (ushort)(1 + pdu.Length); // unit id + pdu
|
||||
adu[4] = (byte)(len >> 8);
|
||||
adu[5] = (byte)(len & 0xFF);
|
||||
adu[6] = unitId;
|
||||
Buffer.BlockCopy(pdu, 0, adu, 7, pdu.Length);
|
||||
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
cts.CancelAfter(_timeout);
|
||||
await _stream.WriteAsync(adu.AsMemory(), cts.Token).ConfigureAwait(false);
|
||||
await _stream.FlushAsync(cts.Token).ConfigureAwait(false);
|
||||
|
||||
var header = new byte[7];
|
||||
await ReadExactlyAsync(_stream, header, cts.Token).ConfigureAwait(false);
|
||||
var respTxId = (ushort)((header[0] << 8) | header[1]);
|
||||
if (respTxId != txId)
|
||||
throw new InvalidDataException($"Modbus TxId mismatch: expected {txId} got {respTxId}");
|
||||
var respLen = (ushort)((header[4] << 8) | header[5]);
|
||||
if (respLen < 1) throw new InvalidDataException($"Modbus response length too small: {respLen}");
|
||||
var respPdu = new byte[respLen - 1];
|
||||
await ReadExactlyAsync(_stream, respPdu, cts.Token).ConfigureAwait(false);
|
||||
|
||||
// Exception PDU: function code has high bit set.
|
||||
if ((respPdu[0] & 0x80) != 0)
|
||||
{
|
||||
var fc = (byte)(respPdu[0] & 0x7F);
|
||||
var ex = respPdu[1];
|
||||
throw new ModbusException(fc, ex, $"Modbus exception fc={fc} code={ex}");
|
||||
}
|
||||
|
||||
return respPdu;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Distinguish socket-layer failures (eligible for reconnect-and-retry) from
|
||||
/// protocol-layer failures (must propagate — retrying the same PDU won't help if the
|
||||
/// PLC just returned exception 02 Illegal Data Address).
|
||||
/// </summary>
|
||||
private static bool IsSocketLevelFailure(Exception ex) =>
|
||||
ex is EndOfStreamException
|
||||
|| ex is IOException
|
||||
|| ex is SocketException
|
||||
|| ex is ObjectDisposedException;
|
||||
|
||||
private async Task TearDownAsync()
|
||||
{
|
||||
try { if (_stream is not null) await _stream.DisposeAsync().ConfigureAwait(false); }
|
||||
catch { /* best-effort */ }
|
||||
_stream = null;
|
||||
try { _client?.Dispose(); } catch { }
|
||||
_client = null;
|
||||
}
|
||||
|
||||
private static async Task ReadExactlyAsync(Stream s, byte[] buf, CancellationToken ct)
|
||||
{
|
||||
var read = 0;
|
||||
|
||||
@@ -0,0 +1,53 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies the driver's Modbus-exception → OPC UA StatusCode translation end-to-end
|
||||
/// against the dl205.json pymodbus profile. pymodbus returns exception 02 (Illegal Data
|
||||
/// Address) for reads outside the configured register ranges, matching real DL205/DL260
|
||||
/// firmware behavior per <c>docs/v2/dl205.md</c> §exception-codes. The driver must surface
|
||||
/// that as <c>BadOutOfRange</c> (0x803C0000) — not <c>BadInternalError</c> — so the
|
||||
/// operator sees a tag-config diagnosis instead of a generic driver-fault message.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205ExceptionCodeTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_FC03_at_unmapped_register_returns_BadOutOfRange()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
// Address 16383 is the last cell of hr-size=16384 in dl205.json; address 16384 is
|
||||
// beyond the configured HR range. pymodbus validates and returns exception 02
|
||||
// (Illegal Data Address).
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("Unmapped",
|
||||
ModbusRegion.HoldingRegisters, Address: 16383,
|
||||
DataType: ModbusDataType.UInt16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-exc");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["Unmapped"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x803C0000u,
|
||||
"DL205 returns exception 02 for an FC03 at an unmapped register; driver must translate to BadOutOfRange (not BadInternalError)");
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,88 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// Unit tests for the Modbus-exception-code → OPC UA StatusCode mapping added in PR 52.
|
||||
/// Before PR 52 every server exception + every transport failure collapsed to
|
||||
/// BadInternalError (0x80020000), which made field diagnosis "is this a bad tag or a bad
|
||||
/// driver?" impossible. These tests lock in the translation table documented on
|
||||
/// <see cref="ModbusDriver.MapModbusExceptionToStatus"/>.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class ModbusExceptionMapperTests
|
||||
{
|
||||
[Theory]
|
||||
[InlineData((byte)0x01, 0x803D0000u)] // Illegal Function → BadNotSupported
|
||||
[InlineData((byte)0x02, 0x803C0000u)] // Illegal Data Address → BadOutOfRange
|
||||
[InlineData((byte)0x03, 0x803C0000u)] // Illegal Data Value → BadOutOfRange
|
||||
[InlineData((byte)0x04, 0x80550000u)] // Server Failure → BadDeviceFailure
|
||||
[InlineData((byte)0x05, 0x80550000u)] // Acknowledge (long op) → BadDeviceFailure
|
||||
[InlineData((byte)0x06, 0x80550000u)] // Server Busy → BadDeviceFailure
|
||||
[InlineData((byte)0x0A, 0x80050000u)] // Gateway path unavailable → BadCommunicationError
|
||||
[InlineData((byte)0x0B, 0x80050000u)] // Gateway target failed to respond → BadCommunicationError
|
||||
[InlineData((byte)0xFF, 0x80020000u)] // Unknown code → BadInternalError fallback
|
||||
public void MapModbusExceptionToStatus_returns_informative_status(byte code, uint expected)
|
||||
=> ModbusDriver.MapModbusExceptionToStatus(code).ShouldBe(expected);
|
||||
|
||||
private sealed class ExceptionRaisingTransport(byte exceptionCode) : IModbusTransport
|
||||
{
|
||||
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
=> Task.FromException<byte[]>(new ModbusException(pdu[0], exceptionCode, $"fc={pdu[0]} code={exceptionCode}"));
|
||||
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_surface_exception_02_as_BadOutOfRange_not_BadInternalError()
|
||||
{
|
||||
var transport = new ExceptionRaisingTransport(exceptionCode: 0x02);
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.ReadAsync(["T"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x803C0000u, "FC03 at an unmapped register must bubble out as BadOutOfRange so operators can spot a bad tag config");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Write_surface_exception_04_as_BadDeviceFailure()
|
||||
{
|
||||
var transport = new ExceptionRaisingTransport(exceptionCode: 0x04);
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var writes = await drv.WriteAsync(
|
||||
[new WriteRequest("T", (short)42)],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
writes[0].StatusCode.ShouldBe(0x80550000u, "FC06 returning exception 04 (CPU in PROGRAM mode) maps to BadDeviceFailure");
|
||||
}
|
||||
|
||||
private sealed class NonModbusFailureTransport : IModbusTransport
|
||||
{
|
||||
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
=> Task.FromException<byte[]>(new EndOfStreamException("socket closed mid-response"));
|
||||
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_non_modbus_failure_maps_to_BadCommunicationError_not_BadInternalError()
|
||||
{
|
||||
// Socket drop / timeout / malformed frame → transport-layer failure. Should surface
|
||||
// distinctly from tag-level faults so operators know to check the network, not the config.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => new NonModbusFailureTransport());
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.ReadAsync(["T"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x80050000u);
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,146 @@
|
||||
using System.Net;
|
||||
using System.Net.Sockets;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// Exercises <see cref="ModbusTcpTransport"/> against a real TCP listener that can close
|
||||
/// its socket mid-session on demand. Verifies the PR 53 reconnect-on-drop behavior: after
|
||||
/// the "first" socket is forcibly torn down, the next SendAsync must re-establish the
|
||||
/// connection and complete the PDU without bubbling an error to the caller.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class ModbusTcpReconnectTests
|
||||
{
|
||||
/// <summary>
|
||||
/// Minimal in-process Modbus-TCP stub. Accepts one TCP connection at a time, reads an
|
||||
/// MBAP + PDU, replies with a canned FC03 response echoing the request quantity of
|
||||
/// zeroed bytes, then optionally closes the socket to simulate a NAT/firewall drop.
|
||||
/// </summary>
|
||||
private sealed class FlakeyModbusServer : IAsyncDisposable
|
||||
{
|
||||
private readonly TcpListener _listener;
|
||||
public int Port => ((IPEndPoint)_listener.LocalEndpoint).Port;
|
||||
public int DropAfterNTransactions { get; set; } = int.MaxValue;
|
||||
private readonly CancellationTokenSource _stop = new();
|
||||
private int _txCount;
|
||||
|
||||
public FlakeyModbusServer()
|
||||
{
|
||||
_listener = new TcpListener(IPAddress.Loopback, 0);
|
||||
_listener.Start();
|
||||
_ = Task.Run(AcceptLoopAsync);
|
||||
}
|
||||
|
||||
private async Task AcceptLoopAsync()
|
||||
{
|
||||
while (!_stop.IsCancellationRequested)
|
||||
{
|
||||
TcpClient? client = null;
|
||||
try { client = await _listener.AcceptTcpClientAsync(_stop.Token); }
|
||||
catch { return; }
|
||||
|
||||
_ = Task.Run(() => ServeAsync(client!));
|
||||
}
|
||||
}
|
||||
|
||||
private async Task ServeAsync(TcpClient client)
|
||||
{
|
||||
try
|
||||
{
|
||||
using var _ = client;
|
||||
var stream = client.GetStream();
|
||||
while (!_stop.IsCancellationRequested && client.Connected)
|
||||
{
|
||||
var header = new byte[7];
|
||||
if (!await ReadExactly(stream, header)) return;
|
||||
var len = (ushort)((header[4] << 8) | header[5]);
|
||||
var pdu = new byte[len - 1];
|
||||
if (!await ReadExactly(stream, pdu)) return;
|
||||
|
||||
var fc = pdu[0];
|
||||
var qty = (ushort)((pdu[3] << 8) | pdu[4]);
|
||||
var respPdu = new byte[2 + qty * 2];
|
||||
respPdu[0] = fc;
|
||||
respPdu[1] = (byte)(qty * 2);
|
||||
// data bytes stay 0
|
||||
|
||||
var respLen = (ushort)(1 + respPdu.Length);
|
||||
var adu = new byte[7 + respPdu.Length];
|
||||
adu[0] = header[0]; adu[1] = header[1];
|
||||
adu[4] = (byte)(respLen >> 8); adu[5] = (byte)(respLen & 0xFF);
|
||||
adu[6] = header[6];
|
||||
Buffer.BlockCopy(respPdu, 0, adu, 7, respPdu.Length);
|
||||
await stream.WriteAsync(adu);
|
||||
await stream.FlushAsync();
|
||||
|
||||
_txCount++;
|
||||
if (_txCount >= DropAfterNTransactions)
|
||||
{
|
||||
// Simulate NAT/firewall silent close: slam the socket without a
|
||||
// protocol-level goodbye, which is what DL260 + an intermediate
|
||||
// middlebox would look like from the client's perspective.
|
||||
client.Client.Shutdown(SocketShutdown.Both);
|
||||
client.Close();
|
||||
return;
|
||||
}
|
||||
}
|
||||
}
|
||||
catch { /* best-effort */ }
|
||||
}
|
||||
|
||||
private static async Task<bool> ReadExactly(NetworkStream s, byte[] buf)
|
||||
{
|
||||
var read = 0;
|
||||
while (read < buf.Length)
|
||||
{
|
||||
var n = await s.ReadAsync(buf.AsMemory(read));
|
||||
if (n == 0) return false;
|
||||
read += n;
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
_stop.Cancel();
|
||||
_listener.Stop();
|
||||
await Task.CompletedTask;
|
||||
}
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Transport_recovers_from_mid_session_drop_and_retries_successfully()
|
||||
{
|
||||
await using var server = new FlakeyModbusServer { DropAfterNTransactions = 1 };
|
||||
await using var transport = new ModbusTcpTransport("127.0.0.1", server.Port, TimeSpan.FromSeconds(2), autoReconnect: true);
|
||||
await transport.ConnectAsync(TestContext.Current.CancellationToken);
|
||||
|
||||
// First transaction succeeds; server then closes the socket.
|
||||
var pdu = new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 };
|
||||
var first = await transport.SendAsync(unitId: 1, pdu, TestContext.Current.CancellationToken);
|
||||
first[0].ShouldBe((byte)0x03);
|
||||
|
||||
// Second transaction: the connection is dead, but auto-reconnect must transparently
|
||||
// spin up a new socket, resend, and produce a valid response. Before PR 53 this would
|
||||
// surface as EndOfStreamException / IOException to the caller.
|
||||
var second = await transport.SendAsync(unitId: 1, pdu, TestContext.Current.CancellationToken);
|
||||
second[0].ShouldBe((byte)0x03);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Transport_without_AutoReconnect_propagates_drop_to_caller()
|
||||
{
|
||||
await using var server = new FlakeyModbusServer { DropAfterNTransactions = 1 };
|
||||
await using var transport = new ModbusTcpTransport("127.0.0.1", server.Port, TimeSpan.FromSeconds(2), autoReconnect: false);
|
||||
await transport.ConnectAsync(TestContext.Current.CancellationToken);
|
||||
|
||||
var pdu = new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 };
|
||||
_ = await transport.SendAsync(unitId: 1, pdu, TestContext.Current.CancellationToken);
|
||||
|
||||
await Should.ThrowAsync<Exception>(async () =>
|
||||
await transport.SendAsync(unitId: 1, pdu, TestContext.Current.CancellationToken));
|
||||
}
|
||||
}
|
||||