#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A capped Gateway HistoryReadEvents read broke out of the gRPC stream as soon
as the page was full. Abandoning a gateway stream cancels the RPC, which the
gateway treats as a connection fault: it evicts its pooled historian session,
so the next read reconnects and concurrent reads on that session fail.
The read now keeps consuming the stream past the cap without collecting it,
bounded by ServerHistorian:Gateway:EventDrainBudget (default 10000 rows; 0 =
the old abandon-at-cap). Rows of a foreign source never count toward the
budget before the "more events" signal is seen, so an abandoned stream never
answers a page as complete. A paged-vs-unpaged fuzz (random tie series,
foreign rows, caps 1..500, budgets 0..10000) pins the page contents and the
drain; it found that abandon-before-signal case.
ReadEventsAsync and the native AtTime arm now rethrow a caller cancellation
instead of recording it as a backend failure.
Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV