Add FocasDriverMediumFindingsTests.cs with regression coverage for the
five Medium findings:
- 003: InitializeAsync throws when tag's DeviceHostAddress is absent
from Devices (two variants: typo host, wrong port; also happy path)
- 004: DiscoverAsync emits ViewOnly for tags with Writable:true
- 005: GetHealth() is consistent after ten concurrent ReadAsync calls
- 006: Read recovers after the client is externally disposed, creating
a fresh client rather than wedging with BadCommunicationError
- 012: Factory full-round-trip with all three opt-in config sections
(FixedTree + AlarmProjection + HandleRecycle) with all subfields
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
EnsureConnectedAsync now disposes and nulls any existing non-connected
client before creating a fresh one via _clientFactory.Create().
Previously the method reused a cached client via ConnectAsync, but a
client disposed by a HandleRecycle race or prior teardown would hit
FocasWireClient.ThrowIfDisposed on every subsequent call, leaving the
device permanently wedged with BadCommunicationError and no recovery
path until ReinitializeAsync.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Guard all _health field accesses with Volatile.Read / Volatile.Write.
ReadAsync, WriteAsync, and ProbeLoopAsync run on different threads and
several updates are read-modify-write (new DriverHealth(_, _health.X, _)).
Without volatile semantics a concurrent update can be lost or a stale
LastSuccessfulRead timestamp propagated. DriverHealth is an immutable
record so Volatile is sufficient — no lock needed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
DiscoverAsync now unconditionally emits SecurityClassification.ViewOnly
for every user-authored FOCAS tag. Previously the SecurityClass was
tag.Writable ? Operate : ViewOnly, but WireFocasClient.WriteAsync always
returns BadNotWritable — advertising Operate misleads OPC UA clients
and the DriverNodeManager ACL layer into granting write permission on
nodes that can never be written.
Updated FocasCapabilityTests.DiscoverAsync_emits_pre_declared_tags to
assert ViewOnly for the writable-by-config tag so it matches the
corrected behaviour.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Throw InvalidOperationException at InitializeAsync when a tag's
DeviceHostAddress does not match any entry in the Devices list, naming
both the tag and the unresolved host. Previously the missing-device
check was guarded by a TryGetValue so a typo silently bypassed
capability-matrix validation and deferred the error to per-read
BadNodeIdUnknown — the opposite of the documented "fail at load" goal.
Also resolves findings 004, 005, and 006 in the same file:
- 004: DiscoverAsync now unconditionally emits ViewOnly for all user
tags; the Writable config field no longer influences security class
because the wire backend always returns BadNotWritable.
- 005: All _health reads use Volatile.Read and all writes use
Volatile.Write so concurrent readers observe a consistent reference
and read-modify-write sequences capture a stable snapshot.
- 006: EnsureConnectedAsync disposes and nulls any existing
non-connected client before creating a fresh one, preventing
ObjectDisposedException loops after a HandleRecycle race or teardown.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Driver.FOCAS-001: FocasDriverConfigDto exposed no FixedTree / AlarmProjection /
HandleRecycle sections, so a deployment that opted into those features per
docs/drivers/FOCAS.md had the sections silently dropped by case-insensitive
JSON parsing and the features stayed at their disabled defaults. Added
FocasFixedTreeDto / FocasAlarmProjectionDto / FocasHandleRecycleDto and Build*
mappers in CreateInstance that populate the matching FocasDriverOptions
properties; a missing section or field keeps its existing default.
Driver.FOCAS-002: the fixed-tree bootstrap probe classified ProgramInfo as
"supported" whenever GetProgramInfoAsync returned non-null, but WireFocasClient
.GetProgramInfoAsync substituted defaults instead of throwing on a FOCAS error
return, so a CNC series answering EW_FUNC/EW_NOOPT for cnc_exeprgname2 /
cnc_rdopmode still got the Program/ and OperationMode/ subtrees. The method now
throws InvalidOperationException when neither the program-name nor the op-mode
read is IsOk, so SafeTryProbe correctly suppresses the capability.
Added FocasFactoryConfigTests covering the three opt-in config sections
round-tripping through CreateInstance and the fixed-tree bootstrap classifying
ProgramInfo as unsupported when the probe throws. Added an internal
FocasDriver.Options test seam.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Reviewed all 31 src/ production projects against the 10-category
checklist in REVIEW-PROCESS.md. Each module gets its own findings.md;
code-reviews/README.md is regenerated from them.
334 findings: 6 Critical, 46 High, 126 Medium, 156 Low.
Critical findings:
- Server-001: WriteNodeIdUnknown recurses unconditionally — a HistoryRead
on an unresolvable node crashes the process (remote DoS).
- Admin-001/002: app-wide auth bypass (RouteView not AuthorizeRouteView)
plus unauthenticated mutating routes.
- Core.Scripting-001: System.Environment reachable from operator scripts;
Environment.Exit() terminates the server.
- Core.AlarmHistorian-001: rowIds/events parallel-list desync on a corrupt
payload misapplies outcomes — silent alarm-event data loss.
- Driver.Galaxy-001: ReconnectSupervisor is built but never triggered, so
a transient gateway drop permanently kills the event stream.
All findings are Status=Open; resolution is tracked per REVIEW-PROCESS.md
section 4. Review only — no source code changed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>