Joseph Doherty fc08892eb3 fix(modbus-fixture): run pymodbus sim without asyncio debug mode; FC03 healthcheck + watchdog (#909)
Root cause: pymodbus 3.13's `pymodbus.simulator` console script hard-codes
asyncio.run(run_main(), debug=True). Debug mode captures a traceback per
scheduled callback and logs callbacks slower than 100 ms (the "took 0.146
seconds" lines in #909). Side by side on the shared docker host (closed-loop
FC03 clients, 2 s deadline): 100 clients got ~120-170 req/s, p99 1.6-1.9 s
with client timeouts in debug mode vs ~2400 req/s, p99 ~135 ms without it.
The shared sim also carries the docker-dev rig's 49 Modbus drivers on each of
central-1/central-2 (98 sockets, ~220 req/s at idle), which is above the
debug-mode capacity, so a test run on top was answered late ("Cancel send,
because not connected!") and timed out.

- run_simulator.py: same CLI as pymodbus.simulator, debug=False, plus a watchdog
  thread that exits after 3 failed FC03 probes so restart: unless-stopped
  replaces the container (docker has no restart-on-unhealthy).
- fc3_probe.py: stdlib FC03 read with a deadline (MBAP or RTU framing); the
  compose healthcheck.
- docker-compose.yml: shared anchor for every pymodbus service: new entrypoint,
  `project: lmxopcua` label, restart: unless-stopped, healthcheck, bounded
  json-file logs.
- README: why, the numbers, and how to diagnose load.
2026-11-13 11:03:08 -05:00
Joseph Doherty 4a8c9badce docs(modbus-rtu): note the co-running :5021 rtu_over_tcp fixture in Docker README + Dockerfile
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 14:36:00 -04:00
Joseph Doherty 650e27075f test(modbus-rtu): add rtu_over_tcp pymodbus fixture + RTU-over-TCP integration tests
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 14:29:10 -04:00
Joseph Doherty 00f39c849e docs(modbus-tests): document profile-cycling gotcha; sweep #2 was a false alarm
v2-ci / build (pull_request) Successful in 4m13s
v2-ci / unit-tests (pull_request) Failing after 9m41s
The 2026-07 integration sweep flagged the Modbus non-standard profiles as
8F/5F/3F/8F and guessed 'pymodbus 4.x drift'. Re-investigation shows that was
wrong on both counts:

- The image runs the PINNED pymodbus 3.13.0 (verified via import pymodbus;
  __version__). The '...removed in v4' log is 3.13.0's forward-deprecation
  warning, misread as running 4.x.
- The failures were a fixture-cycling artifact: each profile is a separate
  profile-gated compose service sharing :5020, and a plain 'docker compose down'
  (no --profile) does NOT stop the running profile container. It kept holding
  :5020; the next '--profile up' container silently failed to bind (compose
  still says 'Started'), so every later profile run hit the STALE sim. Proven by
  a raw Modbus probe: the 'mitsubishi' sim served DL205's 0xCAFE at HR0.

After force-removing all modbus containers and bringing up each profile cleanly
(verifying it actually published :5020), all four pass: dl205 16/16,
mitsubishi 13/13, s7_1500 10/10, exception_injection 17/17. No OtOpcUa or test
code change needed.

Added a profile-cycling gotcha + reliable-cycle recipe to Docker/README.md and
corrected the sweep record. Integration-sweep follow-up #2.
2026-07-15 05:12:52 -04:00
Joseph Doherty c6082aa0b9 fix(admin-e2e): register missing DI services so ClusterDetail interactive circuit boots
UnsTabDragDropE2ETests were timing out at the 'UNS Structure' nav-link
locator because AdminWebAppFactory never registered AdminHubConnectionFactory
/ HubTokenService / DataProtection — ClusterDetail.razor's @inject threw at
circuit boot, so the page never advanced past the Loading placeholder. 2 → 3
pass after the registrations land. Also documents the Modbus standard-vs-
exception_injection coverage matrix in the fixture README + cross-references
docs/drivers/AbServer-Test-Fixture.md from each Emulate test so a developer
landing on a skipped test has a direct doc pointer.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-24 01:07:17 -04:00
Joseph Doherty 969b0847a1 docs: update path references for module-folder reorganization
Rewrite src/ and tests/ project paths in docs, CLAUDE.md, README.md, and
test-fixture READMEs to the new module-folder layout (Core/Server/Drivers/
Client/Tooling). References to retired v1 projects (Galaxy.Host/Proxy/Shared,
the legacy monolithic test projects) are left untouched.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 02:10:29 -04:00
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>