Commit Graph

4 Commits

Author SHA1 Message Date
Joseph Doherty
49644fc7fd test(fixtures): migrate integration-test fixture defaults to 10.100.0.35
CLAUDE.md "Docker Workflow" claims (per the 2026-04-28 migration note)
that all fixture-class default endpoints were rewritten to target the
shared Docker host at 10.100.0.35. Audit during today's e2e run showed
the claim was incomplete — five fixture classes still defaulted to
localhost / 127.0.0.1, causing every fixture-touching integration test
to skip with "endpoint unreachable" on a fresh box that hadn't set
the override env vars.

Files corrected:

  - tests/.../Modbus.IntegrationTests/ModbusSimulatorFixture.cs
      DefaultEndpoint: localhost:5020 → 10.100.0.35:5020
  - tests/.../S7.IntegrationTests/Snap7ServerFixture.cs
      DefaultEndpoint: localhost:1102 → 10.100.0.35:1102
  - tests/.../OpcUaClient.IntegrationTests/OpcPlcFixture.cs
      DefaultEndpoint: opc.tcp://localhost:50000 → opc.tcp://10.100.0.35:50000
  - tests/.../AbCip.IntegrationTests/AbServerFixture.cs
      Host default + ResolveHost fallback: 127.0.0.1 → 10.100.0.35
  - tests/.../AbLegacy.IntegrationTests/AbLegacyServerFixture.cs
      Host default + ResolveEndpoint fallback: 127.0.0.1 → 10.100.0.35

XML doc comments referencing the old localhost defaults were updated in
the same pass so the class-summary documentation matches the actual
default. The override-via-env-var mechanism (MODBUS_SIM_ENDPOINT,
AB_SERVER_ENDPOINT, AB_LEGACY_ENDPOINT, S7_SIM_ENDPOINT,
OPCUA_SIM_ENDPOINT) is unchanged — pointing at a real PLC or a
locally-running container still works exactly as before.

Verification:
  - Solution-wide dotnet build: 0 errors.
  - S7.IntegrationTests: 3/3 pass without env-var override.
  - OpcUaClient.IntegrationTests: 3/3 pass without env-var override.
  - Modbus.IntegrationTests: 4/38 (same as the env-var-override run —
    the 2 failures + 32 skips are pre-existing fixture-profile
    mismatches unrelated to this fix).
  - AbCip.IntegrationTests / AbLegacy.IntegrationTests: same results
    as the env-var-override run.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 19:32:23 -04:00
Joseph Doherty
ebc0511c72 fix(driver-opcuaclient): resolve High code-review findings (Driver.OpcUaClient-001..-005)
Driver.OpcUaClient-001 — ReadAsync/WriteAsync/DiscoverAsync captured the
session before acquiring _gate, so a reconnect that completed while the
operation was blocked on the gate left the wire call bound to a stale,
closed session. All three now re-read Session (and parse NodeIds) inside
the _gate critical section after WaitAsync returns.

Driver.OpcUaClient-002 — OnReconnectComplete ignored the give-up (null
session) case, permanently wedging the driver with no Faulted signal and
no reconnect loop. The give-up branch now transitions HostState to
Faulted, sets a Faulted DriverHealth with an explanatory message, and
re-arms a fresh SessionReconnectHandler (TryRearmReconnect) against the
last-known session so an always-on gateway self-heals.

Driver.OpcUaClient-003 — BrowseRecursiveAsync discarded browse
continuation points, silently truncating large remote folders.
It now loops on BrowseResult.ContinuationPoint calling BrowseNextAsync
and appending each page until the continuation point is empty.

Driver.OpcUaClient-004 — driver-specs.md §8 namespace handling was
absent. Added NamespaceMap (built from session.NamespaceUris at connect,
rebuilt on reconnect) which persists discovered NodeIds in the
server-stable nsu=<uri>;... form; reads/writes re-resolve that form
against the current session so a remote namespace-table reorder no
longer misaddresses nodes. Added the TargetNamespaceKind option +
UnsMappingTable and ValidateNamespaceKind startup enforcement.

Driver.OpcUaClient-005 — OnKeepAlive read/wrote _reconnectHandler
without a lock, racing the SDK keep-alive timer thread and leaking
handlers. The check-and-set in OnKeepAlive, the take-and-clear in
ShutdownAsync, and the dispose/re-arm in OnReconnectComplete now all
run inside the _probeLock critical section.

Adds OpcUaClientNamespaceTests (11 xUnit + Shouldly regression tests)
covering ValidateNamespaceKind and the NamespaceMap stable encoding.
Reconnect/browse wire paths remain fixture-gated per finding -015.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 06:41:28 -04:00
Joseph Doherty
969b0847a1 docs: update path references for module-folder reorganization
Rewrite src/ and tests/ project paths in docs, CLAUDE.md, README.md, and
test-fixture READMEs to the new module-folder layout (Core/Server/Drivers/
Client/Tooling). References to retired v1 projects (Galaxy.Host/Proxy/Shared,
the legacy monolithic test projects) are left untouched.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 02:10:29 -04:00
Joseph Doherty
a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00