Joseph Doherty 2cb8a2c317 fix(install): worker isolation survives a folder swap: recorded settings, -Reapply, -Verify, swap script (#901)
v2-ci / unit-tests (push) Has been cancelled
An upgrade that swaps the install folder dropped the explicit ScriptWorker isolation ACEs on script-worker\, the
install folder and a copied-back pki\ (vd03 2026-11-13). Re-applying needed the operator to repeat the arguments.

- Install-ScriptWorkerIsolation.ps1 records its effective settings (InstallRoot, HostServiceAccount, PeCacheDir,
  HostServiceName, ConfigureHostService) beside DenyPaths under ...\Services\OtOpcUaScriptWorker\Parameters (new plan
  step SettingsRecord) and locks that key to SYSTEM + Administrators (protected DACL; no secrets recorded).
- -Reapply: re-apply from the record, no arguments; prints a summary line (changed/unchanged).
- -Verify: check only, [ok]/[MISSING] per step, exit 1 when anything is missing. -Uninstall also works from the record.
  A node isolated by a pre-#901 installer (DenyPaths only) must run the full-argument install once; both modes say so.
- Invoke-OtOpcUaInstallSwap.ps1: preflight -> stop -> move live/candidate -> carry appsettings/pki/logs ->
  -Reapply -> -Verify -> start; a failed -Verify leaves the service stopped. Also the rollback (-NoCarry).
- Tests: dry-run harness 101/101 (record + argument rules; record-key SDDL mutation turns 2 red). The Windows test adds
  swap -> Verify fails (exactly the 3 lost ACEs) -> Reapply (3 changed) -> Verify ok -> Reapply 12/12 unchanged, PE-cache
  and firewall negative controls, the swap script, and the pre-#901 refusal; 52/52 on windev under 5.1 and 7, with a
  scratch local host account and with SYSTEM. Evidence: scripts/validation/opcua-windows-service/evidence/2026-11-13-windev-901-reapply-verify.
- Docs: ServiceHosting isolation section; vd03 pack (swap step, rollback, post-deploy gate, one-time full-argument run),
  the 2026-11-13 vd03 record, and the QA pack (QA swap preceded the isolation install; ACLs checked intact over SMB on
  vq03/vq04 2026-11-13; next-deploy procedure).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 02:06:10 -05:00
Joseph Doherty a83bf1fa27 fix(opcua): a configured OpcUa:EnabledSecurityProfiles list replaces the default, so None can be dropped (#879)
v2-ci / unit-tests (push) Has been cancelled
ConfigurationBinder appends configured collection items to an existing list, so
the pre-filled [None, Sign, SignAndEncrypt] default made "drop None" a no-op:
every deployment that listed only the secure profiles still advertised an
unsigned/unencrypted None endpoint.

EnabledSecurityProfiles is now null by default; ResolveEnabledSecurityProfiles()
applies the unchanged three-profile default only when nothing is configured.
A set-but-empty list fails startup validation and BuildSecurityPolicies no
longer falls back to a None endpoint on empty input (it throws). Sweep of all
options classes found no other non-empty pre-filled collection default.

Tests: options binding (indexed, JSON, env forms, default, empty, bad name), a
booted-server wire test (no None endpoint, None connection refused with
BadSecurityPolicyRejected, secure connection works; default case is the control).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:38:42 -05:00
Joseph Doherty 1172687d4b test(validation): #800 gate re-run on windev with the fixed isolation installer, both PowerShell hosts
v2-ci / unit-tests (push) Has been cancelled
Re-runs only the ScriptWorker step on windev (master da948e5f, SDK 2.0.1, 16 vCPUs): install as the OtOpcUaHost service,
repo Install-ScriptWorkerIsolation.ps1 applied/re-applied/uninstalled twice under pwsh 7 and Windows PowerShell 5.1,
restricted worker, pipe refuses the admin, runner Healthy, strict-peer/API-key matrix on, then cleanup. The harness drops
-PatchedIsolation, gains -PrepareFrom candidate and -ApplyHost, and suffixes the isolation evidence with -Label.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:24:01 -05:00
Joseph Doherty be28aa4432 fix(opcua-client): send UserName passwords in the legacy RSA format so 65-char API keys log in to SDK 1.5 servers (#880)
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.

LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.

OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.

Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:12:27 -05:00
Joseph Doherty ac4c4d40dc test(validation): #800 Windows service gate harness + windev results (SDK 1.5 -> 2.0.1 in place, rollback)
v2-ci / unit-tests (push) Has been cancelled
Adds scripts/validation/opcua-windows-service/: a phased PowerShell gate (Invoke-ServiceGate.ps1)
that installs the known-good build as the real OtOpcUaHost service via Install-Services.ps1, seeds
LocalDb through the production cache API (Seeder, built against the baseline tree), upgrades in
place with config/PKI/LocalDb carried with their ACLs, starts/stops through the SCM, runs a strict
SDK 2 probe matrix (Sign + SignAndEncrypt, valid/wrong/unknown/disabled/anonymous keys, untrusted
client and server), exercises the ScriptWorker isolation, rolls back and cleans up.

windev 2026-11-12 (efb9197a -> 438484fd -> efb9197a): app cert CEF9D91F... reused byte-for-byte
with identical PKI SDDL on every start, all gating checks pass, 0 secrets in logs. Findings filed:
#879 (None endpoint cannot be dropped), #880 (SDK 2 client 65-char key vs SDK 1.5 server:
rollback/QA risk), #883 (Install-ScriptWorkerIsolation.ps1 fails on pwsh 7 and 5.1; runtime
isolation proven with the patch in the evidence directory).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 10:28:49 -05:00