RedundancyStateActor derived the driver Primary from ClusterState.RoleLeader("driver").
Akka offers two different notions of a "first" member and they are not the same
one: role leader is the lowest-ADDRESSED Up member (host, then port), while
ClusterSingletonManager places singletons on the OLDEST — lowest up-number.
They agree on a freshly-formed cluster, which is why every existing test passed.
They diverge after any restart: the restarted node re-joins as the youngest while
keeping its address, so if it holds the lower address it becomes role leader while
the singletons stay put. The snapshot would then name a Primary that is not
hosting the work, and every Primary-gated surface follows it — inbound device
writes, native-alarm acks, the fleet-wide alerts emit, and the alarm-history
drain would all enable on the wrong node while the node actually running the
singletons stayed gated off.
BuildSnapshot now selects the oldest Up member carrying the driver role, matching
singleton placement. Leaving members are excluded: a node handing its singletons
over must not be named Primary.
NodeRedundancyState.IsRoleLeaderForDriver is renamed IsDriverPrimary, and
NodeHealthInputs.IsDriverRoleLeader likewise. Keeping the old names would have
left the wire contract asserting a derivation the code no longer uses — the same
drift that made this defect invisible.
Proven by a real two-node cluster rather than a mock. RedundancyPrimaryElectionTests
binds the first-joining node to the HIGHER port, so oldest and lowest-address name
different nodes, and includes a fixture assertion that the divergence actually
occurred — without it the real assertion could pass for the wrong reason. Positive
control: restoring the RoleLeader derivation turns exactly the two election tests
red while the fixture check stays green.
Runtime.Tests 440 passed, ControlPlane.Tests 82, Cluster.Tests 36.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Reshapes the placeholder buffered-counter actor into a thin fire-and-forget
bridge over the existing IAlarmHistorianSink contract. Default sink is
NullAlarmHistorianSink; production deployments override the DI binding to
SqliteStoreAndForwardSink wrapping WonderwareHistorianClient (the v1
components in src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware*
are reused verbatim — actor is just a mailbox-friendly entry point).
- HistorianAdapterActor.Props(IAlarmHistorianSink?) — null defaults to NullAlarmHistorianSink
- Receive<AlarmHistorianEvent>: fire-and-forget sink.EnqueueAsync
- Receive<GetStatus>: returns sink.GetStatus() (queue depth + drain state)
- ServiceCollectionExtensions.AddOtOpcUaRuntime registers the default sink
- WithOtOpcUaRuntimeActors spawns the actor + registers HistorianAdapterActorKey
- Program.cs calls AddOtOpcUaRuntime when hasDriver
Tests: 2 new (forward-to-sink + GetStatus). Runtime suite 17 → 18.
Replaces the Ok=true stub with a TCP connect to the peer's OPC UA port (4840
default) with a 2s timeout. A successful connect indicates the OPC UA server
process is up + accepting connections — enough for the redundancy calculator
to treat the peer as live. A full secure-channel Hello/Acknowledge handshake
is overkill for what the redundancy calc consumes and would pull in the OPC
UA Client SDK + a PKI setup. Upgrade later if a deeper liveness signal is ever
required.
Probe extracts the host from NodeId by stripping the :port suffix (commit
5cfbe8b encoded host:port into NodeId for cluster-member identity).
Tests: 2 new tests — Ok=true against a live TcpListener on a chosen port,
Ok=false against an unreachable endpoint. All 17 Runtime tests pass (was 16
covering only the message-contract surface).